7-4  REPAIR 

 

 

Should the MEZZO need reconditioning, maintenance or repairs at any time, we 
recommend that it be sent, in its original packing, to the dealer where it was bought. 
Please include a detailed description of the fault or the reconditioning work that is 
required.  

 

 

WARNING! The device may only be opened, or alterations carried out, by 
authorised customer service technicians! 
 

 

7-5  TRANSPORT THE MICROSCOPE 

 

 

If possible try to avoid moving the microscope.  

 

 

When moving and handling the stereo microscope, carry it with both hands. Thereby 
holding the bearing rod (11) with one hand, and the base plate with the other (13).  

 

 

Always hold the microscope upright. 

 

 

  

TECHNICAL DATA 

 

  

8-1  TECHNICAL INFORMATION - MICROSCOPE 

 

  

  

LCD glare protection filter and LED light module, for use only in 
conjunction with PUK precision welding devices 

 

  

 

 

Device suitable solely for welding in dry surroundings! 

 

  

 

 

Operating temperature 

+5°C to +40°C 

  

 

 

Mains Voltage for optionally available mains adapter plug 

~230 V / 50-60 Hz 
+/-15% 

  

 

 

Bulb  “LED-module” 

2,5W / 800mA 

  

 

 

Protection category 

III 

  

 

 

Insulation class 

  

 

 

Degree of protection 

IP 20 

 

 

 

Weight 

3,7 Kg 

  

8-2

 

OPTICAL INFORMATION - MICROSCOPE 

 

  

 

 

Lens 

1,0 

  

 

 

Eye-piece lenses 

10x 

  

 

 

Work distance 

140 mm 

 

 

 

Degree of magnification 

10x 

 

 

 

Size of “field of vision” in mm 

20 mm 

 

8-3

 

TECHNICAL INFORMATION - LCD SHUTTER 

 

 

 

 

Degree of luminescence 

DIN 3 

 

 

 

Degree of obscurity 

DIN 11 

 

 

 

Switching time 

<50ms 

 

 

 

UV protection 

>UV 15 

 

 

 

IR protection  

>IR 14 

 

 

 

 

 

 

 

 

 

Содержание PUK 3s

Страница 1: ...y qualified personnel and then only for its designated use and in accordance with the guidelines here within The manufacturer accepts no responsibility and is in no way liable for damage caused by imp...

Страница 2: ...etting the viewing distance 7 5 3 Focussing 7 5 4 Dioptre settings 8 6 CARE AND MAINTENANCE 6 1 Maintenance of the optical components 8 6 2 Maintenance of the electrical components 9 7 TROUBLE SHOOTIN...

Страница 3: ...her application of the appliance other than the above stated is prohibited It is prohibited to use this apparatus out of doors Use only in dry surroundings 2 INTRODUCTION Arc welding without protectiv...

Страница 4: ...must be shut down and removed from the power supply it must also be secured against accidental re operation or activation It is likely and can be expected that a safe operation of the device is no lo...

Страница 5: ...ut together using excessive force Mount the bearing rod 11 to the base plate 13 using the bolt that is included tighten it with an open ended spanner Place upright on a clean flat and stable surface S...

Страница 6: ...n using these models it is necessary to use a transformer plug This is available as an optional extra Plug in the transformer plug into a suitable mains socket WARNING before connecting the stereo mic...

Страница 7: ...hat when both hands are resting on the hand rests 14 the work piece can easily be guided to the tip of the electrode Here remember to first correctly position the hand piece in the supporting arm Swit...

Страница 8: ...t eye open look through the left eye piece and adjust the focus by turning the dioptre adjustment 2 on the left eye piece tube 3 until the viewed object is in focus 6 CARE AND MAINTENENCE Under normal...

Страница 9: ...it flush with the underside of the supporting arm 7 TROUBLE SHOOTING PROBLEM CAUSE SOLUTION 7 1 PROBLEMS WITH ELECTRICAL COMPONENTS A The LED light doesn t work Cable is not attached Switch on the cor...

Страница 10: ...h the other 13 Always hold the microscope upright 8 TECHNICAL DATA 8 1 TECHNICAL INFORMATION MICROSCOPE LCD glare protection filter and LED light module for use only in conjunction with PUK precision...

Страница 11: ...posal system 10 EG CONFORMITY DECLARATION The Manufacturer Lampert Werktechnik GmbH Ettlebener Str 27 97440 Werneck Germany declares herewith that the following product Welding microscope with integra...

Отзывы: