30
5. Pull the motor connector plug leaving the drive (1) off
of the power module.
6. Remove the drive [2].
☞
For this disassemble the screws (3).
Mounting the drive
It is to be observed that the cables are not damaged or
extremely bent when being placed. They must be placed
according to their diameter in a reasonable radius.
☞
Otherwise danger of fire through short circuits!
Assembly of the drive is done analogue in reverse order to
chapter
☞
Replace previously removed cable binders by new ones.
☞
Then carry out a function test.
☞