GENERAL REQUIREMENTS
CAUTION:
EQUIPMENT MUST BE INSTALLED BY A QUALIFIED
HEATING PERSON.
CAUTION:
ONLY CLASS A ALL-FUEL OR SOLID FUEL CHIM-
NEYS INTENDED FOR USE WITH YOUR WOOD-
CHUCK SHOULD BE USED.
FIRST AND ABOVE ALL is safety for you and your
family.
MUST USE: Class A Masonry or ULC listed, manufac-
tured Class A All Fuels Chimney.
RECOMMENDED SIZE: Rectangular 8"x12" or Round
8".
DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE
SERVING ANOTHER APPLIANCE. The Woodchuck is
to be used in conjunction with a listed gas or oil fired fur-
nace or as a central furnace.
ELECTRICAL SUPPLY: 115 volts, 60HZ, 1 Phase, less
than 12 amps.
Install system with 0.2 static pressure.
Flue setting .06 W.C. Maxto .04 W.C. Min.
Wood or coal related fires are caused almost exclusively
by installation, operation or maintenance errors; but not
by unsafe equipment.
IMPORTANT: Check with your local state and federal
codes on installation at your local fire department.
PLACEMENT AND MINIMUM
CLEARANCES
CAUTION:
FURNACE
MUST
BE
INSTALLED
ON
A
NON-COMBUSTIBLE FLOOR OR 3/8" THICK FIRE-
PROOF MILLBOARD OR EQUIVALENT.
Locating your unit is very important for proper draft and
most efficient heating possible. See figure 7.
INSTALLATION
FIGURE 7 LOCATING THE WOODCHUCK