background image

10

BURNING WOOD IN YOUR

WOODCHUCK

1. Adjust draft channel selector, figure 5, to appropriate

fuel setting on Model 2900/4000. (On model 526 with

manual draft, open it fully. Also on the Model 526 pull

the manual draft selector rod on the front of the unit

fully out. This will allow the draft to exhaust out the rear

of the stack and create a hotter burn. Adjust back in

once the fire is established to maintain proper stack

temperature.) Place several pieces of crumpled paper

in the center of your Woodchuck. Criss-cross a couple

of handfuls of dry kindling wood 3/4" thickness, then

several small dry pieces of firewood. Ignite the paper

and close the door. Do not attempt to open the door im-

mediately after igniting the fire. There could be a flame

flash out.

2. It will take 5-10 minutes for the fire to establish itself.

Once you have some good red hot burning embers,

add larger pieces of wood. All chimneys and hookups

are different. After 3-4 fires, you’ll find out how your unit

works for the best starting.

3. After about 30-40 minutes you can adjust the draft

according to your needs. Adjust smoke pipe damper

according to your needs also.

NOTE: On airtight units, the burning time is controlled

mostly by the draft controls on the furnace, contrary to

the old type of pot belly stoves where the smoke pipe

damper controlled the burning time.

NOTE: With new steel, there is a small amount of oil or

dirt on the metal and you may smell an odor. Provide

adequate ventilating to home during the first operation.

Your new Woodchuck is capable of putting out many

BTU’s, so treat it with respect. Don’t fully load your fur-

nace or open all drafts fully until you have become thor-

oughly familiar with the operation of the furnace.

NOTE: A full load does not always give the best results

for your needs.

4. When loading your Woodchuck with existing hot

coals, rake red hot embers over grates evenly. Put a

few small pieces of wood on the coals first, then

load-up.

5. If you have the automatic draft control, turn low limit

by-pass switch to “On”. Turn thermostat up to activate

auto draft and proceed as with manual draft. Once the

unit is warmed up you can turn the low limit by-pass

switch to “OFF”. This will allow the auto draft to shut off

if the unit runs out of fuel while you are gone.

CAUTION:

WAIT 10 SECONDS ON FIRST LATCH BEFORE RE-

FUELING. OPENING LOADING DOOR RAPIDLY CAN

CAUSE A FLAME TO FLASH OUT THE DOOR. THIS

OCCURS WHEN THERE IS UNBURNT FUEL AND A

LARGE AMOUNT OF GASES ON TOP OF THE FIRE-

BOX. WHEN THE DOOR IS OPEN, OXYGEN IS COM-

BINED WITH GASES AND IGNITES. USE CAUTION

WHEN OPENING LOADING DOOR.

HELPFUL HINTS

Adjust the draft to the proper setting for your home

needs. The chimney, hookups, and kind of wood will

also be a factor.

Your Woodchuck is capable of holding very large logs.

DO NOT try to add a log that is larger than you can

easily place in the furnace. You will get the best effi-

ciency when you add only the amount of wood needed

for a 6 to 8 hour burn.

In the spring and fall, the weather is mild, which will al-

low you to burn very large loads of wood for long peri-

ods of time and hence accumulate very large amounts

of creosote. KEY: Stack temperature should be

300°F-400°F for good burning. An external flue temper-

ature thermometer (Woodchuck part #08-0084) is in-

cluded in the owner’s manual package for monitoring

stack temperature. Install the flue temperature ther-

mometer at the rear of the furnace on the smoke pipe

where it connects to the collar on the back of the

Woodchuck. 300-400 degrees should be maintained

when the Woodchuck is operating in the burn cycle with

the forced draft blower running to eliminate a creosote

build up. (If the unit has a manual draft or a natural

draft, monitor the flue temperature when the drafts are

in the open position). Depending on the weather, you

may not need a full load of wood for a good over night

burn. You will get best efficiency when you add only the

amount of wood needed until the next time you are

available to load.

Always try to place the logs so air can flow between

them -this will enhance combustion considerably.

ASH REMOVAL

When burning wood, run your poker over top of the

grate to be sure grate slots are clear of burnt fuel. This

should be done every morning when there is just a bed

of hot coals.

Содержание WOODCHUCK 2900

Страница 1: ...08 2012 Installation must be made in accordance with local and state codes which may differ from manual Save these instructions M a n u f a c t u r e d b y Meyer Mfg Corp Phone 715 654 5132 Fax 715 6...

Страница 2: ...a Woodchuck Pride in craftsmanship and engi neering have made your Woodchuck the finest heating appliance available to day Solid fuels are abundant and inexpensive Wood is our only renewable source of...

Страница 3: ...e 13 Trouble Shooting 14 General Requirements 16 Placement and Minimum Clearances 16 Installation 16 Chimney Installation 18 Installing Your Woodchuck 19 Stove Pipe Installation 19 Installation of a B...

Страница 4: ...Door Rapidly Can Cause A Flame To Flash Out The Door Use Caution When Opening Loading Door Unsafe To Load Coal Above Top Of Brick Keep Ash Pan Out Of Unit During Operation Ash Pan Can Get Very Hot As...

Страница 5: ...Secondary Heat Exchange YES Listings UL391 CSA B366 1 M ETLM Firebox Chamber 6 10 cu ft MODEL526 SPECIFICATIONS Height 48 5 Width 26 Depth 28 Blower 850 to 1850 CFM Max BTU Capacity 150 000 Log Size 2...

Страница 6: ...on air must be warm when it enters the firebox to further pro mote complete combustion Your Woodchuck furnace provides all these features and more Here is how when combustion air enters a Woodchuck fu...

Страница 7: ...ng for continuous air movement even during periods of low heat output this stratification is not allowed to take place You are more comfortable and lose less heat through your ceil ings as illustrated...

Страница 8: ...WITHIN MARKED INSTALLATION CLEAR ANCES INSPECT AND CLEAN FLUES AND CHIMNEY REGU LARLY UNDER CERTAIN CONDITIONS OF USE CREO SOTE BUILDUP MAY OCCUR RAPIDLY WAIT 10 SEC ON FIRST LATCH BEFORE RE FUELING...

Страница 9: ...pass switch is also a start up switch When the switch is in the OFF AUTO position the draft blower will run de pendent on the thermostat setting upstairs If fire has dropped to a temperature that is b...

Страница 10: ...ostat up to activate auto draft and proceed as with manual draft Once the unit is warmed up you can turn the low limit by pass switch to OFF This will allow the auto draft to shut off if the unit runs...

Страница 11: ...nds to give off large quantities of volatile gas This gas may accumulate and possibly ig nite causing a backpuff To reduce back puffing open the fire door to the first safety latch position for 15 20...

Страница 12: ...pit will not allow the required air for combustion Keep ash pit clean ASH REMOVAL Ash should always be put into an air tight metal con tainer CAUTION KEEP ASH PAN OUT OF UNIT DURING OPERA TION ASH PA...

Страница 13: ...onth to keep it tuned up and limber OPTIONAL CATALYTIC COMBUSTOR FOR MODELS 2900 4000 NOTE Optional catalyst not recommended for Model 2900 4000 with 6 flue adapter Smoke spillage may oc cur out of do...

Страница 14: ...n Switch blower to the off position Bad wall Ther mostat check by turning it up to 80 and if the draft blower does not turn on replace thermo stat Lo limit bypass on off Replace thermostat When starti...

Страница 15: ...r how good the conditions The use of wet frozen or unseasoned wood The use of soft wood particularly those of high resin content such as plywood or blandex with glue Poor natural draft or an obstructi...

Страница 16: ...or oil fired fur nace or as a central furnace ELECTRICAL SUPPLY 115 volts 60HZ 1 Phase less than 12 amps Install system with 0 2 static pressure Flue setting 06 W C Max to 04 W C Min Wood or coal rela...

Страница 17: ...FROOFWITHIN10 HORIZONTALLY ALSOSEEFIGURE9 ACHIMNEYWHICHRISESWITHINHOUSEISBETTER INSULATEDTHANACHIMNEYWHICHISLOCATEDOUTSIDE THEHOUSEANDISEXPOSEDTOWEATHER THECHIMNEYFLUEMUSTHAVEACROSSSECTIONALAREA ATLEA...

Страница 18: ...y MAKE SURE YOUR WOODCHUCK IS IN STALLED INTO A PROPER CHIMNEY For maximum safety and efficiency never install the Woodchuck furnace into the same chimney serving an other appliance A typical chimney...

Страница 19: ...t experts as to whether use of barometric draft regulators is wise Draft regulators limit the draft the suction pulling air into the appliance A pivoted counter balanced flap is pulled open by the dra...

Страница 20: ...he plenum top may be dangerous so make sure clearances are maintained For the Model 4000 allow at least 4 from ceiling to plenum The ducts fittings grilles and registers should be sized so that the to...

Страница 21: ...R GRATE INSTALLATION FOR MODEL 526 1 Remove standard grates from firebox Assemble com plete shaker grate kit outside of unit Figure 16 2 Assemble the left front bar different from right front bar has...

Страница 22: ...bled grate on the loading door lower frame The grate should be the upside down position Slide the grate front end first into the firebox allowing the front end to lower into the hearth area Once the b...

Страница 23: ...ks that will fit between the bevel cut bricks 4000 Models with have just two 2 thick bricks with bevel cuts that will fit to the outer walls of the firebox 3 Place rectangular brick along side walls o...

Страница 24: ...to form a 90 angle This angle points toward the rear of the firebox FIGURE18 INSTALLOPTIONALCATALYTIC COMBUSTOR MODEL2900 4000 SLOTS IN EXHAUST PIPE CATALYTIC ELEMENT RODS ON RETAINER ASSEMBLE MANUAL...

Страница 25: ...he rear of the fur nace Slide in from the top side figure 21 INSTALL FILTER BOX The filter box is standard on Model 526 Installation in structions are included with Model 526 filter box 1 The filter b...

Страница 26: ...rt control These connections have been routed to a terminal strip on the outside of the comfort control box for convenient connection 4 The circulating blower limit control is factory wired to the com...

Страница 27: ...SHOCK OR BURN DISCONNECT AND LOCKOUT POWER SOURCE BEFORE SERVICING OR INSTALLING ELECTRICAL COMPONENTS FAILURE TO HEED MAY RESULT IN SERIOUS PERSONAL INJURY OR DEATH CAUTION ALL WIRING MUST MEET LOCAL...

Страница 28: ...r Pin 13 05 0004 Handle Access Cover 14 801 2520 1 5Z 1 4x1 1 2 Bolt KEY NO PART NO DESCRIPTION 15 06 0215 Spring 16 814 2520 Z 1 4 Lock Nut 17 05 0002 Small Grate 18 05 0001 Large Grate 19 07 5267 Fr...

Страница 29: ...2902 Ash Door 12 06 1014 Handle Knob Large 13 02 2901 Fuel Door KEY NO PART NO DESCRIPTION 14 06 2902 Fuel Door Gasket 15 07 2901 Side Brick Kit 4 pc 16 07 2902 Rear Brick Kit 2 pc 17 07 2904 Front B...

Страница 30: ...1014 Handle Knob Large 10 06 1013 80 20 Selector Knob 11 06 1001 Ash Pan 12 06 0200 Door Pin KEY NO PART NO DESCRIPTION 13 02 2901 Fuel Door 14 06 2902 Fuel Door Gasket 15 02 2902 Ash Door 16 06 2903...

Страница 31: ...2903 End Rail W 10 3 05 2904 Shaker Bar CC 130 4 05 2905 Shaker Rail WC 2900 05 4001 Shaker Rail WC 4000 5 05 2906 Sleeve WC 2900 05 4003 Sleeve WC 4000 6 05 2908 Handle WC 2900 E423 05 2907 Handle W...

Страница 32: ...Bracket 9 08 0112 Kit Motor Clamp 2 COVER not shown 08 0100 COMFORT CONTROL Item 8 10 11 12 Not Included Order Separately DRAFT Wiring Decal See Next Page 9 KEY NO PART NO DESCRIPTION 1 08 0100 2 Box...

Страница 33: ...33 46 2900 8 Forced Draft Wiring Diagram...

Страница 34: ...Purchase Date Of Installation Name Of Installer Address Phone HOW TO READ YOUR SERIAL NUMBER Your serial number is located on your Certification Panel Example 0085 3582 Model Code Sequence of Build 0...

Страница 35: ...g or negligence or from an attempt to repair the unit by any person not expressly authorized by Meyer Manufacturing Corporation to do the repair Limit of Obligation No one is authorized to make any ot...

Страница 36: ...Box 405 Dorchester Wisconsin 54425 ManufacturedBy MEYERMANUFACTURINGCORPORATION CountyHwy A West P O Box 405 Dorchester Wisconsin54425 0405 Phone 715 654 5132 FAX 715 654 5513 1 800 325 9103 www meye...

Отзывы: