DIAGNOSTIC FLOW CHART FOR
E-88 Unit
These charts are intended to be used as an aid in diagnosing problems on the E-88 unit. They are not a substitute for factory training
and experience. Be certain to read the General Information and Testing Tips sections before attempting any troubleshooting.
IMPORTANT: Maintenance and repairs must be performed with the moldboard on the ground.
General Information
Before any troubleshooting is started, make certain the following conditions are met.
1. The moldboard is pointing straight ahead. This can often be done by coupling the left cylinder into the right cylinder and
pushing the moldboard by hand.
2. The power angling cylinders must be installed correctly on to the plow assembly. The left cylinder (Driver’s side) has a hose
attached with a female half of a coupler at the end; the right cylinder (Passenger side) has a hose attached with a male half
of a coupler at the end.
3. The solenoid wires must be on their proper coil. The “A” coil (black and tan wires) on power angling block labeled “BLK”.
The “B” coil (red and tan wires) on power angling block labeled “RED”. The “C” coil (green and tan wires) on power angling
block labeled “GRN”. The “D” coil (yellow and tane wires) on power angling block labeled “YEL”. The “E” coil (purple and tan
wires) on power angling block labeled “PUR”.
TESTING TIPS
-20-
Many tests do not require removing the Electro Lift
®
unit from the vehicle. However, more thorough testing can be
performed using the Meyer Test Stand which allows direct pressure and amperage readings.
1. Using a screwdriver or other small tool to check for magnetism of the solenoid coils “A”, “B”, “C”, “D” and “E”. Place the tool
on the nut securing the coil and have an assistant operate the switch. You should feel strong magnetic attraction.
2. Use a test light or volt meter to determine whether there is power at the harness.
3. When determining AMP draw of the motor, always obtain the highest value possible, i.e, at maximum raise or maximum angle
with motor running.
4. Proper rotation for the motor is indicated by an arrow located on top side of the (Part # 15889) pump.
5. The pump shaft of a good pump can be turned smoothly using two fingers. If it can’t be turn easily, the pump is too tight and
must be replaced.
6. Pump pressure can be measured at an angle hose (note pressure at full angle) or in the pressure filter port (an adaptor is
necessary for the filter port). Note: The E-88 Unit has a non adjustable pressure relief valve.
7. Flush the complete system including unit, hoses and power angling rams with Meyer Hydra-Flush™ Fluid M-2.
Содержание E-58H
Страница 8: ...E 88 Mount Motor Only 6 FIGURE 1 1...
Страница 9: ...E 88 Dismount Motor and E Solenoid 7 FIGURE 1 2...
Страница 10: ...E 88 Raise Motor and B Solenoid 8 FIGURE 1 3...
Страница 11: ...E 88 Lower A Solenoid 9 FIGURE 1 4...
Страница 12: ...E 88 Angle Left Motor and D Solenoid 10 FIGURE 1 5...
Страница 13: ...E 88 Angle Right Motor and C Solenoid 11 FIGURE 1 6...
Страница 14: ...E 58H E 78 Raise Motor and B Solenoid 12 FIGURE 1 7...
Страница 15: ...E 58H E 78 Lower A Solenoid 13 FIGURE 1 8...
Страница 16: ...E 58H E 78 Angle Left Motor only 14 FIGURE 1 9...
Страница 17: ...E 58H E 78 Angle Right Motor and C Solenoid 15 FIGURE 1 10...
Страница 23: ...21 E 88 ONLY...
Страница 24: ...22 E 88 ONLY...
Страница 25: ...23 E 88 ONLY...
Страница 26: ...24 E 88 ONLY...
Страница 27: ...25 E 88 ONLY...
Страница 29: ...27 E 78 ONLY...
Страница 30: ...E 78 ONLY 28...
Страница 31: ...E 78 ONLY 29...
Страница 32: ...E 78 ONLY 30...
Страница 33: ...31 E 58H ONLY...
Страница 34: ...E 58H ONLY 32...
Страница 35: ...E 58H ONLY 33...
Страница 36: ...E 58H ONLY 34...
Страница 37: ...35 E 78 E 88 Wiring E 58H Wiring...
Страница 40: ...38 E 58H E 78 Exploded View FIGURE 3 2 FIGURE 3 1 E 88 Exploded View...