Meyer Sound Self-Powered Loudspeakers UM-100P Скачать руководство пользователя страница 7

%

Power Supply Fan

The power supply is cooled by a single small internal
fan that turns on low when the unit is first powered up.
The fan doubles its speed as the system is driven with
audio. Since the fan draws air in from, and exhausts it
out the side of the cabinet, there must be at least six
inches on the amplifier’s side of the cabinet and ad-
equate air flow.

UM-P Applications

In half-space loading condition, the UM-P will typically
produce a maximum SPL of 135 dB at 1 meter with a
frequency response down to 60Hz, which is perfect for
vocals and most instruments.  When using the UM-P in
most applications that require SPL in the sub harmonic
frequencies, such as monitoring drums and bass, the
UM-P should be supplemented with a subwoofer such
as the Meyer  USW-1P or 650-P depending on the needs
of the end user. For ideas on integrating the UM-P with
other Meyer Sound products contact Meyer Sound Technical
Support.

The Constant Q design of the horn allows frequencies
outside of the coverage area of the speaker to attenuate
quickly.  This is excellent for monitoring where several
different monitors are used in close proximity. When
placing the monitor carefully consider the coverage
pattern of the UM-P and UM-100P.

The UM-1P’s coverage area is:

  –6 dB points:

45° H x 45° V

–10 dB points:

65° H x 65° V

The UM-100P’s coverage area is:

  –6 dB points:

100° H x 40° V

–10 dB points:

120° H x 60° V

The following drawings illustrate the coverage area of
each horn from three different perspectives in order to
depict the three dimensional coverage pattern.

UM-1P (Side View)

UM-100P (Top View)

UM-100P (Front View)

UM-1P (Front View)

UM-1P (Top View)

UM-100P (Side View)

Содержание Self-Powered Loudspeakers UM-100P

Страница 1: ...Operating Instructions UM P Series UM 1P and UM 100P Self Powered Loudspeakers Copyright 1997 Meyer Sound Laboratories Inc All rights reserved Part 05 079 008 01 Rev B Serial Numbers 981000 and above...

Страница 2: ...es risk of electric shock Declaration of Conformity According to ISO IEC Guide and EN 45014 Safety EN60065 1994 EMC EN55103 1 emmission EN55103 2 immunity Name Meyer Sound Laboratories Inc Address 283...

Страница 3: ...beam width using the 6 dB points has been proposed as the audio industry standard and Meyer Sound adheres to this definition NOTE Unfortunately beamwidth is often used to de scribe the angle at which...

Страница 4: ...1 5Arms 230V for proper operation allowing up to five UM Ps to be powered from one 15A circuit How ever we recommend powering no more than three UM Ps per 15Abranch to allow a 30 margin for peak volt...

Страница 5: ...s for different applications Each module has a 24V Fan connector to power an optional fan see page 7 Each module uses a three pin female XLR audio input connector with a 10 k balanced input impedance...

Страница 6: ...igh limit is above the low limit LED The UM P performs within its acoustical specifications and operates at a normal temperature if the limit LEDs are on for no longer than two seconds and off for at...

Страница 7: ...emented with a subwoofer such as the Meyer USW 1P or 650 P depending on the needs of the end user For ideas on integrating the UM P with otherMeyerSoundproductscontactMeyerSoundTechnical Support The C...

Страница 8: ...m the front of the loudspeaker at the midway point be tween the high and low frequency drivers 2 Connect a full range signal to the loudspeaker and note the frequency response The polarity is correct...

Страница 9: ...high or low driver seems to pro duce sound 1 Make sure the audio signal is full range and has not been filtered in a previous stage of the signal chain If possible monitor the audio source with high...

Страница 10: ...von ausgebildetem Kundenienstpersonal durchgef hrt werden Para reducir el riesgo de descarga el ctrica desconecte de la red el altoparlante antes de instalar el cable de se alizaci n de interfaz de l...

Страница 11: ...Panel with RMS option and standard Looping Audio Input Module Looping Polarity and Attenuating Input Module Summing Audio Input Module On Temp Summing Inputs 24VFan Inputs Limit Earth Chassis Case 22...

Страница 12: ...ersound com http www meyersound com Contact Information 16 5 22 4 16 5 22 4 UM 100P Front 16 5 9 99 UM P Back UM 1P Front 12 6 UM P Top 52 13 8 16 9 AC Input 100 240V 50 60Hz 4A MAX 24VFan Loop Input...

Отзывы: