Power Connector Wiring

Use the following AC cable wiring diagram to create
international or special-purpose power connectors:

brown = hot

blue = 
neutral

yellow/green =
earth ground
(chassis)

AC cable color code

If the colors referred to in the diagram don't correspond
to the terminals in your plug, use the following guide-
lines:

• Connect the blue wire to the terminal marked

with an or colored black.

• Connect the brown wire to the terminal marked

with an L or colored red.

• Connect the green and yellow wire to the terminal

marked with an E (or 

) or colored green (or

green and yellow).

Safety Issues

Do  not  use  a  ground-lifting  adapter  or  cut  the  AC

cable  ground  pin.

Keep all liquids away from the UM-P to avoid hazards

from electrical shock.

Do  not  operate  the  unit  with  worn  or  frayed  cables;

replace them immediately.

If  the  UM-P  will  be  installed  outdoors  contact  Meyer

Sound for information about the rain hood and weather

protection for the drivers and electronics.

While a single UM-P can be hung by its handle bars, do

not hang any additional weight from the cabinet. UM-P

handle bars are not designed to support heavy rigging

loads.

The Modular Rear Panel

The rear panel of the UM-P has two slots for processor
modules. The top slot contains the Audio Input and
Control Module

; the bottom slot contains the optional

Remote Monitoring System™ (RMS) Module

. A blank

plate covers the bottom slot if RMS is not installed.   For
drawings of these modules, see page 13.

Audio Input

There are three, interchangeable Audio Input and Control
Modules with optimized connectors and controls for
different applications. Each module has a 24V Fan
connector to power an optional fan (see page 7).

Each module uses a  three-pin, female XLR audio input
connector with a 10 k

Ω 

balanced input impedance wired

with the following convention:

Pin 1

— 220 k

 to chassis and earth ground (ESD clamped)

Pin 2

— Signal

Pin 3

— Signal

Case

— Earth (AC) ground and chassis

Pins 2 and 3 carry the input as a differential signal. Use
standard audio cables with XLR connectors for balanced
signal sources. A single audio source can drive multiple
UM-Ps with a paralleled input loop, creating an unbuf-
fered hardwired loop connection, with negligible loss
in signal level. For example, since the input impedance
of one UM-P is 10 k

, looping 20 UM-Ps produces a

balanced input impedance of 500

. With a 150

Ω 

audio

source, the 500

 load results in only a 2.28 dB loss.

Looping Audio Input Module

This standard module uses a balanced, female XLR
connector for audio input and a male XLR loop connector
to interconnect multiple speakers. The audio input
connector is hardwired with pin 2 hot to comply with
audio industry standards. The loop connector, wired in
parallel to the audio input, transmits the input signal if
the UM-P is turned off for any reason.

Summing Audio Input Module

This module has a balanced, female XLR connector for
audio input but has, instead of a loop connector, a
second female XLR connector that functions as a summing
input. Applying a signal to one of the inputs results in a
normal signal level. Utilizing both summing inputs
creates a correctly summed mono signal with each input
6 dB below the level of a single input. This is an effective
method for distributing both sides of a stereo signal to
a single UM-P without requiring external level control.

Differential Inputs

Содержание Self-Powered Loudspeakers UM-100P

Страница 1: ...Operating Instructions UM P Series UM 1P and UM 100P Self Powered Loudspeakers Copyright 1997 Meyer Sound Laboratories Inc All rights reserved Part 05 079 008 01 Rev B Serial Numbers 981000 and above...

Страница 2: ...es risk of electric shock Declaration of Conformity According to ISO IEC Guide and EN 45014 Safety EN60065 1994 EMC EN55103 1 emmission EN55103 2 immunity Name Meyer Sound Laboratories Inc Address 283...

Страница 3: ...beam width using the 6 dB points has been proposed as the audio industry standard and Meyer Sound adheres to this definition NOTE Unfortunately beamwidth is often used to de scribe the angle at which...

Страница 4: ...1 5Arms 230V for proper operation allowing up to five UM Ps to be powered from one 15A circuit How ever we recommend powering no more than three UM Ps per 15Abranch to allow a 30 margin for peak volt...

Страница 5: ...s for different applications Each module has a 24V Fan connector to power an optional fan see page 7 Each module uses a three pin female XLR audio input connector with a 10 k balanced input impedance...

Страница 6: ...igh limit is above the low limit LED The UM P performs within its acoustical specifications and operates at a normal temperature if the limit LEDs are on for no longer than two seconds and off for at...

Страница 7: ...emented with a subwoofer such as the Meyer USW 1P or 650 P depending on the needs of the end user For ideas on integrating the UM P with otherMeyerSoundproductscontactMeyerSoundTechnical Support The C...

Страница 8: ...m the front of the loudspeaker at the midway point be tween the high and low frequency drivers 2 Connect a full range signal to the loudspeaker and note the frequency response The polarity is correct...

Страница 9: ...high or low driver seems to pro duce sound 1 Make sure the audio signal is full range and has not been filtered in a previous stage of the signal chain If possible monitor the audio source with high...

Страница 10: ...von ausgebildetem Kundenienstpersonal durchgef hrt werden Para reducir el riesgo de descarga el ctrica desconecte de la red el altoparlante antes de instalar el cable de se alizaci n de interfaz de l...

Страница 11: ...Panel with RMS option and standard Looping Audio Input Module Looping Polarity and Attenuating Input Module Summing Audio Input Module On Temp Summing Inputs 24VFan Inputs Limit Earth Chassis Case 22...

Страница 12: ...ersound com http www meyersound com Contact Information 16 5 22 4 16 5 22 4 UM 100P Front 16 5 9 99 UM P Back UM 1P Front 12 6 UM P Top 52 13 8 16 9 AC Input 100 240V 50 60Hz 4A MAX 24VFan Loop Input...

Отзывы: