Meyer Sound MPS-482HP Скачать руководство пользователя страница 11

MPS-482HP OPERATING INSTRUCTIONS

11

CHAPTER 2: MPS-482HP FRONT AND REAR PANELS

MPS-482HP FRONT PANEL

The MPS-482HP front panel includes a power switch and 
LEDs for monitoring each loudspeaker channel.

AC Power

The MPS-482HP is powered on and off with the AC Power 
switch.

Fuse, Voltage, and Load Current LEDs (1–2)

The Fuse, Voltage and Load Current LEDs are useful for 
verifying if a channel fuse is open/blown, whether each 
channel output has voltage, and whether the connected 
loudspeakers are receiving DC power and audio.

Red Fuse LEDs (1-2)

A lit red LED indicates a blown or open fuse on that channel. 
If the Red LED is lit, power down the MPS-482HP and 
replace the fuse for that channel. 

TIP: 

To replace a fuse, use a screwdriver to 

gently turn the appropriate fuse cover 

(open: counterclockwise; close: clockwise). 

Blue Voltage LEDs (1–2)

The blue Voltage LEDs indicate whether voltage is present 
for the channel outputs. These LEDs should be lit when the 
MPS-482HP is powered on. The MPS-482HP’s intelligent 
circuit protection shields connected loudspeakers from 
surges and shorts. When a blue Voltage LED is unlit and its 
corresponding green Load Current LED is off, a surge or 
short has been detected for the channel. If a surge or short 
is encountered, or the Red LED is lit, power down the 
MPS-482HP, inspect the loudspeaker cabling, and replace 
the fuse for that channel.

Table 1 lists the possible states for the Blue Voltage LEDs.

CAUTION: 

When a blue Voltage LED is unlit, 

power down the MPS-482HP, inspect the 

loudspeaker cabling for that channel, and check the 
fuse.

Green Load Current LEDs (1–2)

The green Load Current LEDs indicate whether 
loudspeakers are connected to the channel outputs and 
receiving power. As a channel’s audio signal level increases, 
its LED glows brighter. If an LED is not lit, check that the 
channel’s Voltage LED is lit and verify the cable connection 
to the loudspeaker. Also check to see if the red LED is lit, 
indicating a blown fuse for that channel. If a surge or short is 
encountered, power down the MPS-482HP, inspect the 
loudspeaker cabling for that channel, and check the fuse 
and replace if necessary.

Table 2 lists the possible states for the Load Current LEDs.

MPS-482HP Power Supply Front Panel

MPS-482HP Channel LEDs

Fuse Access

Table 1: Blue Voltage LEDs

State

Cause

Recommended Action

Unlit

(all LEDs)

MPS-482HP not 
powered on or is 
unplugged

Verify the MPS-482HP is 
powered on and verify its 
power source

Unlit

(single LED)

Surge or short 
encountered for channel

Power down the MPS-
482HP, inspect the 
loudspeaker cabling for 
the channel and check 
fuse

!

Содержание MPS-482HP

Страница 1: ...Keep these important operating instructions Check www meyersound com for updates OPERATING INSTRUCTIONS POWER MPS 482HP Power Supply ...

Страница 2: ...aw no part of this publication may be reproduced stored in a retrieval system or transmitted in any form or by any means electronic mechanical recording or otherwise without prior written permission from Meyer Sound Ashby 5C Ashby 8C HMS 5 HMS 10 HMS 12 HMS 15 MM 10XP MM 4XP M Noise MPS 482HP UP 4slim UP4 XP and all alpha numeric designations for Meyer Sound products and accessories are trademarks...

Страница 3: ...apparatus during lightning storms or when unused for long periods of time 14 If equipped with an external fuse holder the replaceable fuse is the only user serviceable item When replacing the fuse only use the same type and the same value 15 Refer all other servicing to qualified service personnel Servicing is required when the apparatus has been dam aged in any way such as when the power supply c...

Страница 4: ...schriften verstossen und zu Stromunfällen führen Das Produkt nicht an einem Ort aufstellen an dem es direkter Wassereinwirkung oder übermäßig hoher Luft feuchtigkeit ausgesetzt werden könnte solange es sich nicht um ein Produkt handelt dass mit der Meyer Sound Weather Protection Option ausgestattet ist Vermeiden Sie das Eindringen von Wasser oder Fremd körpern in das Innere des Produkts Stellen Si...

Страница 5: ... El receptáculo debe estar conectado a un fusible o disyuntor La conexión a cualquier otro tipo de receptáculo representa un riesgo de descarga eléctrica y puede violar los códigos eléctri cos locales No instale el aparato en lugares húmedos o mojados sin usar el equipo de protección contra intemperie de Meyer Sound No permita que penetre agua u otros objetos extraños en el interior del aparato No...

Страница 6: ...IMPORTANT SAFETY INSTRUCTIONS vi ...

Страница 7: ... 14 Chapter 3 Powering Loudspeakers with the MPS 482HP 15 Chapter 4 MPS 482HP Mounting Accessories 17 Optional Accessories 17 Appendix A MPS 482HP Cable Accessories 19 Phoenix Loudspeaker Cables 19 Phoenix and EN3 Cable Connectors and Adapters 19 Appendix B Assembling Loudspeaker Cables 21 Assembling Phoenix to Phoenix Loudspeaker Cables 21 Assembling Phoenix to EN3 Loudspeaker Cables 22 Assemblin...

Страница 8: ...viii ...

Страница 9: ...deal for powering surrounds in immersive configurations CAUTION Only connect to 48 V DC Meyer Sound Powered Speakers See the labeling on the bottom of the unit for a list of compatible speakers Meyer Sound s externally powered loudspeakers include on board amplification and signal processing circuits that store DC power and tolerate voltage drops up to 30 percent to accommodating light gauge cable...

Страница 10: ...CHAPTER 1 INTRODUCTION 10 ...

Страница 11: ...tected for the channel If a surge or short is encountered or the Red LED is lit power down the MPS 482HP inspect the loudspeaker cabling and replace the fuse for that channel Table 1 lists the possible states for the Blue Voltage LEDs CAUTION When a blue Voltage LED is unlit power down the MPS 482HP inspect the loudspeaker cabling for that channel and check the fuse Green Load Current LEDs 1 2 The...

Страница 12: ...x connector supports two channels with the following pinout from left to right pin 1 channel one ground pin 2 channel one signal positive pin 3 channel one signal negative pin 4 channel 2 ground pin 5 channel 2 signal positive pin 6 channel 2 signal negative Channel inputs default to being routed to their corresponding channel outputs but channel one can also be routed to the channel two output wi...

Страница 13: ...smaller than 10 times their output impedance To drive two loudspeakers linked from a single channel input the source device should have an output impedance of less than 500 ohms Channel Outputs The MPS 482HP s two channel outputs deliver DC power 48 V DC and balanced audio to two loudspeakers The channel outputs are available as Phoenix 5 pin male connectors NOTE For information about cable requir...

Страница 14: ...ak voltage drop in long AC cable runs according to the following formula V pk drop I pk x R cable total Maximum Instantaneous Peak Current a rating for fast reacting magnetic breakers Inrush Current the spike of initial current encountered when powering on For current draw values for the MPS 482HP with connected loudspeakers see Appendix C MPS 482HP Specifications The minimum electrical service am...

Страница 15: ...nnectors When connecting loudspeakers equipped with Phoenix connectors to the MPS 482HP power supply use Phoenix 5 pin female to Phoenix 5 pin female cables TIP With the MPS 482HP you can use two separate cables for loudspeaker connections a 2 conductor cable for DC power and a 3 conductor cable for balanced audio both attached to a single Phoenix connector on each cable end This approach allows y...

Страница 16: ...CHAPTER 3 POWERING LOUDSPEAKERS WITH THE MPS 482HP 16 ...

Страница 17: ...ce for cable routing The enclosure design includes cable routing strain relief tabs The bracket accommodates M6 fasteners RMT MPS 482HP Rack Mount Tray Allows mounting of one or two power supplies on a standard EIA 19 inch wide rack The 2RU tray height facilitates cooling of the MPS 482HP power supply as the area above the unit is empty The rack mount tray comes with one face tray cover to use if ...

Страница 18: ...CHAPTER 4 MPS 482HP MOUNTING ACCESSORIES 18 ...

Страница 19: ...9 45 100 ft 30 5 m 28 163 009 46 150 ft 45 7 m 28 163 009 51 EN3 5 pin female to Phoenix 5 pin female White Plenum 10 ft 3 m 28 163 009 52 20 ft 6 1 m 28 163 009 53 30 ft 9 1 m 28 163 009 54 50 ft 15 2 m 28 163 009 55 100 ft 30 5 m 28 163 009 56 150 ft 45 7 m Phoenix and EN3 Cable Connectors and Adapters Part Number Connector Adapter Use 484 065 Phoenix 5 pin female cable mount connector Connects ...

Страница 20: ...APPENDIX A MPS 482HP CABLE ACCESSORIES 20 ...

Страница 21: ... connectors you need a Phoenix 5 pin female to Phoenix 5 pin female cable The following procedure documents how to assemble this cable To assemble a Phoenix to Phoenix cable 1 If the cable has not yet been stripped strip one end of the cable Strip the outer shielding by 1 inch and then strip the black red blue and white wires by 0 275 inch 2 Insert the five exposed conductors into the five cable h...

Страница 22: ...rocedure documents how to assemble this cable If you are starting with an EN3 to pigtail cable you can skip steps 4 7 in this procedure To assemble a Phoenix to EN3 cable 1 If the cable has not yet been stripped strip one end of the cable Strip the outer shielding by 1 inch and then strip the black red blue and white wires by 0 275 inch 2 Insert the five exposed conductors into the five cable hole...

Страница 23: ...cheme 7 Reassemble the EN3 5 pin female connector Align the coupling ring s side notches with the cord connector s side notches and slide the couple ring onto the cord connector Carefully insert the end of the cable clamp housing into the cord connector until it locks into place Snap the cable clamps in the cable clamp housing into their compartments Slide the boot forward so it covers the cable c...

Страница 24: ...sert the five exposed conductors into the five cable holes in a Phoenix 5 pin male cable mount connector Use the following wiring scheme 3 Secure the conductors by tightening the five screws in the Phoenix cable mount connector Screws should be torqued to 5 6 Nm 4 4 5 3 In Lbs CAUTION Screws should not be inserted into the Phoenix connector while the connector rests in a mating plug Doing so will ...

Страница 25: ... wiring scheme 7 Reassemble the ECO M 7 pin female connector Return the sleeve to the angled hood and secure it with the insert connector Return the seal and pinch ring to the angled hood and secure it with the pressing screw 8 Verify the wiring polarity is correct for both cable ends ECO M 7 Pin Female Cable Mount Connector Assembled Left and Disassembled Right Pin Destinations for ECO M 7 Pin Fe...

Страница 26: ...APPENDIX B ASSEMBLING LOUDSPEAKER CABLES 26 ...

Страница 27: ...dio signal Pin 5 Audio signal Output Voltage 48 V DC per channel supports NEC class 2 wiring AC POWER AC Connector powerCON 20 Voltage Selection Automatic Safety Rated Voltage Range 100 240 V AC 50 60 Hz CURRENT DRAW Idle Current 0 139 A 115 V AC 60 Hz 0 071 A 230 V AC 50 Hz 0 150 A rms 100 V AC 60 Hz PHYSICAL Dimensions 1RU in height x 1 2 width rack mount W 8 50 in 216 mm x H 1 85 in 47 mm x D 8...

Страница 28: ...APPENDIX C MPS 482HP SPECIFICATIONS 28 ...

Страница 29: ...MPS 482HP OPERATING INSTRUCTIONS 29 MPS 482HP DIMENSIONS 8 50 in 216 mm 7 75 in 197 mm 1 66 in 42 mm R 0 19 in 5 mm 6 75 in 171 mm 8 62 in 219 mm ...

Страница 30: ...tial area is likely to cause harmful interference in which case the user will be required to correct the interference at their own expense This device complies with Part 15 of the FCC rules Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired oper...

Страница 31: ......

Страница 32: ...Meyer Sound Laboratories Inc 2832 San Pablo Avenue Berkeley CA 94702 1 510 486 1166 www meyersound com 2019 Meyer Sound All rights reserved MPS 482HP Operating Instructions PN 05 285 005 01 A2 ...

Отзывы: