CHAPTER 2: MPS-482HP FRONT AND REAR PANELS
MPS-482HP FRONT PANEL
The MPS-482HP front panel includes a power switch and
LEDs for monitoring each loudspeaker channel.
AC Power
The MPS-482HP is powered on and off with the AC Power
switch.
Fuse, Voltage, and Load Current LEDs (1–2)
The Fuse, Voltage and Load Current LEDs are useful for
verifying if a channel fuse is open/blown, whether each
channel output has voltage, and whether the connected
loudspeakers are receiving DC power and audio.
Red Fuse LEDs (1-2)
A lit red LED indicates a blown or open fuse on that channel.
If the Red LED is lit, power down the MPS-482HP and
replace the fuse for that channel.
TIP:
To replace a fuse, use a screwdriver to
gently turn the appropriate fuse cover
(open: counterclockwise; close: clockwise).
Blue Voltage LEDs (1–2)
The blue Voltage LEDs indicate whether voltage is present
for the channel outputs. These LEDs should be lit when the
MPS-482HP is powered on. The MPS-482HP’s intelligent
circuit protection shields connected loudspeakers from
surges and shorts. When a blue Voltage LED is unlit and its
corresponding green Load Current LED is off, a surge or
short has been detected for the channel. If a surge or short
is encountered, or the Red LED is lit, power down the
MPS-482HP, inspect the loudspeaker cabling, and replace
the fuse for that channel.
Table 1 lists the possible states for the Blue Voltage LEDs.
CAUTION:
When a blue Voltage LED is unlit,
power down the MPS-482HP, inspect the
loudspeaker cabling for that channel, and check the
fuse.
Green Load Current LEDs (1–2)
The green Load Current LEDs indicate whether
loudspeakers are connected to the channel outputs and
receiving power. As a channel’s audio signal level increases,
its LED glows brighter. If an LED is not lit, check that the
channel’s Voltage LED is lit and verify the cable connection
to the loudspeaker. Also check to see if the red LED is lit,
indicating a blown fuse for that channel. If a surge or short is
encountered, power down the MPS-482HP, inspect the
loudspeaker cabling for that channel, and check the fuse
and replace if necessary.
Table 2 lists the possible states for the Load Current LEDs.
MPS-482HP Power Supply Front Panel
MPS-482HP Channel LEDs
Fuse Access
Table 1: Blue Voltage LEDs
State
Cause
Recommended Action
Unlit
(all LEDs)
MPS-482HP not
powered on or is
unplugged
Verify the MPS-482HP is
powered on and verify its
power source
Unlit
(single LED)
Surge or short
encountered for channel
Power down the MPS-
482HP, inspect the
loudspeaker cabling for
the channel and check
fuse
!
Содержание MPS-482HP
Страница 6: ...IMPORTANT SAFETY INSTRUCTIONS vi ...
Страница 8: ...viii ...
Страница 10: ...CHAPTER 1 INTRODUCTION 10 ...
Страница 16: ...CHAPTER 3 POWERING LOUDSPEAKERS WITH THE MPS 482HP 16 ...
Страница 18: ...CHAPTER 4 MPS 482HP MOUNTING ACCESSORIES 18 ...
Страница 20: ...APPENDIX A MPS 482HP CABLE ACCESSORIES 20 ...
Страница 26: ...APPENDIX B ASSEMBLING LOUDSPEAKER CABLES 26 ...
Страница 28: ...APPENDIX C MPS 482HP SPECIFICATIONS 28 ...
Страница 31: ......