Meyer Sound MPS-482HP Скачать руководство пользователя страница 4

 IMPORTANT SAFETY INSTRUCTIONS

iv

PowerCon Use

CAUTION: 

Disconnect the mains plug before 

disconnecting the power cord from the 

speaker.

English 

To reduce the risk of electric shock, disconnect the 
apparatus from the AC mains before installing audio 
cable. Reconnect the power cord only after making all 
signal connections. 

Connect the apparatus to a two-pole, three-wire ground-
ing mains receptacle. The receptacle must be connected 
to a fuse or circuit breaker. Connection to any other type 
of receptacle poses a shock hazard and may violate 
local electrical codes. 

Do not install the apparatus in wet or humid locations 
without using weather protection equipment from Meyer 
Sound. 

Do not allow water or any foreign object to get inside the 
apparatus. Do not put objects containing liquid on or 
near the unit.

To reduce the risk of overheating the apparatus, avoid 
exposing it to direct sunlight. Do not install the unit near 
heat-emitting appliances, such as a room heater or 
stove. 

If equipped with an external fuse holder, the replaceable 
fuse is the only item that can be serviced by the user. 
When replacing the fuse, only use the same type and 
value. 

This apparatus contains potentially hazardous voltages. 
Do not attempt to disassemble the unit. The only user-
serviceable part is the fuse. All other repairs should be 
performed only by factory-trained service personnel.

Deutsch

Zur Minimierung der Gefahr eines elektrischen Schlages 
trennen Sie das Produkt vor dem Anschluss von Audio-
und/oder Steuerleitungen vom Stromnetz. Das Netzka-
bel darf erst nach Herstellung aller Signalverbindungen 
wieder eingesteckt werden.

Das Produkt an eine vorschriftsgemäss installierte 
dreipolige Netzsteckdose (Phase, Neutralleiter, Schut-
zleiter) anschließen. Die Steckdose muss vorschrifts-
gemäß mit einer Sicherung oder einem 
Leitungsschutzschalter abgesichert sein. Das 
Anschließen des Produkts an eine anders ausgeführte 

Stromversorgung kann gegen Vorschriften verstossen 
und zu Stromunfällen führen.

Das Produkt nicht an einem Ort aufstellen, an dem es 
direkter Wassereinwirkung oder übermäßig hoher Luft-
feuchtigkeit ausgesetzt werden könnte, solange es sich 
nicht um ein Produkt handelt, dass mit der Meyer Sound 
Weather Protection Option ausgestattet ist.

Vermeiden Sie das Eindringen von Wasser oder Fremd-
körpern in das Innere des Produkts. Stellen Sie keine 
Objekte, die Flüssigkeit enthalten, auf oder neben dem 
Produkt ab.

Um ein Überhitzen des Produkts zu verhindern, halten 
Sie das Gerät von direkter Sonneneinstrahlung fern und 
stellen Sie es nicht in der Nähe von wärmeabstrahlenden 
Geräten (z.B. Heizgerät oder Herd) auf.

Bei Ausstattung mit einem externen Sicherungshalter ist 
die austauschbare Sicherung das einzige Gerät, das vom 
Benutzer gewartet werden kann. Verwenden Sie beim 
Austausch der Sicherung nur den gleichen Typ und 
Wert.

Dieses Gerät enthält möglicherweise gefährliche Span-
nungen. Versuchen Sie nicht, das Gerät zu zerlegen. Der 
einzige vom Benutzer zu wartende Teil ist die Sicherung. 
Alle anderen Reparaturen dürfen nur von im Werk ges-
chultem Servicepersonal ausgeführt werden.

Français

Pour éviter tout risque d’électrocution, débranchez 
l’enceinte de la prise secteur avant de mettre en place le 
câble audio.Ne rebranchez le cordon secteur qu’après 
avoir procédé à toutes les connexions de signal audio

Branchez l’enceinte sur une prise murale à deux fiches et 
trois conducteurs avec terre. Cette prise doit être reliée à 
une ligne électrique protégée par un fusible ou un court-
circuit. Utiliser une prise murale de type différent crée 
des risques d’électrocution, et peut enfreindre des régle-
mentations électriques locales.

N’installez pas l’enceinte dans des endroits humides ou 
en présence d’eau sans utiliser d’équipements de pro-
tection adéquats fournis par Meyer Sound.

Ne laissez pas d’eau ou d’objet étranger, quel qu’il soit, 
pénétrer à l’intérieur de l’enceinte. Ne posez pas d’objet 
contenant du liquide sur ou à proximité de l’enceinte. 

Pour réduire les risques de surchauffe, évitez d’exposer 
directement l’enceinte aux rayons du soleil. Ne l’installez 

!

Содержание MPS-482HP

Страница 1: ...Keep these important operating instructions Check www meyersound com for updates OPERATING INSTRUCTIONS POWER MPS 482HP Power Supply ...

Страница 2: ...aw no part of this publication may be reproduced stored in a retrieval system or transmitted in any form or by any means electronic mechanical recording or otherwise without prior written permission from Meyer Sound Ashby 5C Ashby 8C HMS 5 HMS 10 HMS 12 HMS 15 MM 10XP MM 4XP M Noise MPS 482HP UP 4slim UP4 XP and all alpha numeric designations for Meyer Sound products and accessories are trademarks...

Страница 3: ...apparatus during lightning storms or when unused for long periods of time 14 If equipped with an external fuse holder the replaceable fuse is the only user serviceable item When replacing the fuse only use the same type and the same value 15 Refer all other servicing to qualified service personnel Servicing is required when the apparatus has been dam aged in any way such as when the power supply c...

Страница 4: ...schriften verstossen und zu Stromunfällen führen Das Produkt nicht an einem Ort aufstellen an dem es direkter Wassereinwirkung oder übermäßig hoher Luft feuchtigkeit ausgesetzt werden könnte solange es sich nicht um ein Produkt handelt dass mit der Meyer Sound Weather Protection Option ausgestattet ist Vermeiden Sie das Eindringen von Wasser oder Fremd körpern in das Innere des Produkts Stellen Si...

Страница 5: ... El receptáculo debe estar conectado a un fusible o disyuntor La conexión a cualquier otro tipo de receptáculo representa un riesgo de descarga eléctrica y puede violar los códigos eléctri cos locales No instale el aparato en lugares húmedos o mojados sin usar el equipo de protección contra intemperie de Meyer Sound No permita que penetre agua u otros objetos extraños en el interior del aparato No...

Страница 6: ...IMPORTANT SAFETY INSTRUCTIONS vi ...

Страница 7: ... 14 Chapter 3 Powering Loudspeakers with the MPS 482HP 15 Chapter 4 MPS 482HP Mounting Accessories 17 Optional Accessories 17 Appendix A MPS 482HP Cable Accessories 19 Phoenix Loudspeaker Cables 19 Phoenix and EN3 Cable Connectors and Adapters 19 Appendix B Assembling Loudspeaker Cables 21 Assembling Phoenix to Phoenix Loudspeaker Cables 21 Assembling Phoenix to EN3 Loudspeaker Cables 22 Assemblin...

Страница 8: ...viii ...

Страница 9: ...deal for powering surrounds in immersive configurations CAUTION Only connect to 48 V DC Meyer Sound Powered Speakers See the labeling on the bottom of the unit for a list of compatible speakers Meyer Sound s externally powered loudspeakers include on board amplification and signal processing circuits that store DC power and tolerate voltage drops up to 30 percent to accommodating light gauge cable...

Страница 10: ...CHAPTER 1 INTRODUCTION 10 ...

Страница 11: ...tected for the channel If a surge or short is encountered or the Red LED is lit power down the MPS 482HP inspect the loudspeaker cabling and replace the fuse for that channel Table 1 lists the possible states for the Blue Voltage LEDs CAUTION When a blue Voltage LED is unlit power down the MPS 482HP inspect the loudspeaker cabling for that channel and check the fuse Green Load Current LEDs 1 2 The...

Страница 12: ...x connector supports two channels with the following pinout from left to right pin 1 channel one ground pin 2 channel one signal positive pin 3 channel one signal negative pin 4 channel 2 ground pin 5 channel 2 signal positive pin 6 channel 2 signal negative Channel inputs default to being routed to their corresponding channel outputs but channel one can also be routed to the channel two output wi...

Страница 13: ...smaller than 10 times their output impedance To drive two loudspeakers linked from a single channel input the source device should have an output impedance of less than 500 ohms Channel Outputs The MPS 482HP s two channel outputs deliver DC power 48 V DC and balanced audio to two loudspeakers The channel outputs are available as Phoenix 5 pin male connectors NOTE For information about cable requir...

Страница 14: ...ak voltage drop in long AC cable runs according to the following formula V pk drop I pk x R cable total Maximum Instantaneous Peak Current a rating for fast reacting magnetic breakers Inrush Current the spike of initial current encountered when powering on For current draw values for the MPS 482HP with connected loudspeakers see Appendix C MPS 482HP Specifications The minimum electrical service am...

Страница 15: ...nnectors When connecting loudspeakers equipped with Phoenix connectors to the MPS 482HP power supply use Phoenix 5 pin female to Phoenix 5 pin female cables TIP With the MPS 482HP you can use two separate cables for loudspeaker connections a 2 conductor cable for DC power and a 3 conductor cable for balanced audio both attached to a single Phoenix connector on each cable end This approach allows y...

Страница 16: ...CHAPTER 3 POWERING LOUDSPEAKERS WITH THE MPS 482HP 16 ...

Страница 17: ...ce for cable routing The enclosure design includes cable routing strain relief tabs The bracket accommodates M6 fasteners RMT MPS 482HP Rack Mount Tray Allows mounting of one or two power supplies on a standard EIA 19 inch wide rack The 2RU tray height facilitates cooling of the MPS 482HP power supply as the area above the unit is empty The rack mount tray comes with one face tray cover to use if ...

Страница 18: ...CHAPTER 4 MPS 482HP MOUNTING ACCESSORIES 18 ...

Страница 19: ...9 45 100 ft 30 5 m 28 163 009 46 150 ft 45 7 m 28 163 009 51 EN3 5 pin female to Phoenix 5 pin female White Plenum 10 ft 3 m 28 163 009 52 20 ft 6 1 m 28 163 009 53 30 ft 9 1 m 28 163 009 54 50 ft 15 2 m 28 163 009 55 100 ft 30 5 m 28 163 009 56 150 ft 45 7 m Phoenix and EN3 Cable Connectors and Adapters Part Number Connector Adapter Use 484 065 Phoenix 5 pin female cable mount connector Connects ...

Страница 20: ...APPENDIX A MPS 482HP CABLE ACCESSORIES 20 ...

Страница 21: ... connectors you need a Phoenix 5 pin female to Phoenix 5 pin female cable The following procedure documents how to assemble this cable To assemble a Phoenix to Phoenix cable 1 If the cable has not yet been stripped strip one end of the cable Strip the outer shielding by 1 inch and then strip the black red blue and white wires by 0 275 inch 2 Insert the five exposed conductors into the five cable h...

Страница 22: ...rocedure documents how to assemble this cable If you are starting with an EN3 to pigtail cable you can skip steps 4 7 in this procedure To assemble a Phoenix to EN3 cable 1 If the cable has not yet been stripped strip one end of the cable Strip the outer shielding by 1 inch and then strip the black red blue and white wires by 0 275 inch 2 Insert the five exposed conductors into the five cable hole...

Страница 23: ...cheme 7 Reassemble the EN3 5 pin female connector Align the coupling ring s side notches with the cord connector s side notches and slide the couple ring onto the cord connector Carefully insert the end of the cable clamp housing into the cord connector until it locks into place Snap the cable clamps in the cable clamp housing into their compartments Slide the boot forward so it covers the cable c...

Страница 24: ...sert the five exposed conductors into the five cable holes in a Phoenix 5 pin male cable mount connector Use the following wiring scheme 3 Secure the conductors by tightening the five screws in the Phoenix cable mount connector Screws should be torqued to 5 6 Nm 4 4 5 3 In Lbs CAUTION Screws should not be inserted into the Phoenix connector while the connector rests in a mating plug Doing so will ...

Страница 25: ... wiring scheme 7 Reassemble the ECO M 7 pin female connector Return the sleeve to the angled hood and secure it with the insert connector Return the seal and pinch ring to the angled hood and secure it with the pressing screw 8 Verify the wiring polarity is correct for both cable ends ECO M 7 Pin Female Cable Mount Connector Assembled Left and Disassembled Right Pin Destinations for ECO M 7 Pin Fe...

Страница 26: ...APPENDIX B ASSEMBLING LOUDSPEAKER CABLES 26 ...

Страница 27: ...dio signal Pin 5 Audio signal Output Voltage 48 V DC per channel supports NEC class 2 wiring AC POWER AC Connector powerCON 20 Voltage Selection Automatic Safety Rated Voltage Range 100 240 V AC 50 60 Hz CURRENT DRAW Idle Current 0 139 A 115 V AC 60 Hz 0 071 A 230 V AC 50 Hz 0 150 A rms 100 V AC 60 Hz PHYSICAL Dimensions 1RU in height x 1 2 width rack mount W 8 50 in 216 mm x H 1 85 in 47 mm x D 8...

Страница 28: ...APPENDIX C MPS 482HP SPECIFICATIONS 28 ...

Страница 29: ...MPS 482HP OPERATING INSTRUCTIONS 29 MPS 482HP DIMENSIONS 8 50 in 216 mm 7 75 in 197 mm 1 66 in 42 mm R 0 19 in 5 mm 6 75 in 171 mm 8 62 in 219 mm ...

Страница 30: ...tial area is likely to cause harmful interference in which case the user will be required to correct the interference at their own expense This device complies with Part 15 of the FCC rules Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired oper...

Страница 31: ......

Страница 32: ...Meyer Sound Laboratories Inc 2832 San Pablo Avenue Berkeley CA 94702 1 510 486 1166 www meyersound com 2019 Meyer Sound All rights reserved MPS 482HP Operating Instructions PN 05 285 005 01 A2 ...

Отзывы: