![Meusburger H 4062 Скачать руководство пользователя страница 9](http://html1.mh-extra.com/html/meusburger/h-4062/h-4062_user-manual_1781524009.webp)
6.2.3. Switching the machine off
In order to switch off the machine, both manual slide valves must be closed and
then the main switch turned off. This avoids any unwanted untimely movement of
the pallets caused by turning the shut-off valve.
6.2.4. Emergency shut-down
In an emergency, the shut-off valve must be turned off immediately, so as to cut off
the compressed air supply to the entire system.
7. Maintenance, cleaning, servicing
The correct condition and functioning of all mechanical operating parts must be checked prior to
each use. The schedule for these checks must be set in such a way that any faults that arise can be
detected in good time or any damage immediately rectified. The air hoses must be checked daily
for possible damage. In addition, the table‘s surface and shoulders and the moveable plates must
be oiled regularly, otherwise they will be subject to severe corrosion. The shoulders must be che-
cked regularly to make sure that they are firmly attached.
7.1. Auxiliaries and consumables
Meusburger Multi oil VMM 4/1/400 for the regular oiling of corroding parts.
7.2. Replacement parts and parts subject to wear
Replacement parts may simply be ordered from our sales department. Compressed air hoses
should be renewed after no more than 6 years.
8. Troubleshooting and fault correction
8.1. Fault / malfunction – Cause – Correction
In the event of damage to the compressed air circuit, the circuit must be systematically che-
cked from the pneumatic source right through to the moveable plates.
9. Decommissioning
9.1. Temporary shut-down
In the event of temporary shutdown or storage, the entire assembly table must be oiled,
otherwise it will be subject to severe corrosion. It should be stored in a dry place.
10. Disassembly, removal and disposal
10.1. Recycling
As the assembly table is made of iron and plastics only, it may be disposed of via the conven-
tional system of separated rubbish disposal. Assembly tables that have reached the end of
their service life may be returned to Meusburger Georg GmbH for disposal, free of charge.