5.4.3.
Resetting the error register
Each error has to be acknowledged by setting the
{Clear Error}
bit in register
[Lamp Control]
to
“1”.
First of all set the
{Start Lamp}
bit
in register
[Lamp Control]
to 0. Then only the
transgression of the
{Clear Error}
bit from “0” to “1” can reset the
[Error Register]
. After the
PROFIBUS has transmitted the [Lamp Control] Register (check e.g. via the [Error Register]: if
error eliminated all error bits
are „0“ again)
and after an ELC internal synchronisation time of
additional 15 ms, the
{Clear Error}
-bit has to be reset to
„0“
.
PROFIBUS-output-data (Master
→
ELC)
Byte-
No.
0
1
2
3
4
5
Name
[Power
Set
Value]
[Installed
Lamp
Power]
[Lamp
Control]
[User
Register]
↓
Bit
7
6
5
4
3
2
1
0
Name
n/a n/a n/a n/a n/a n/a
Clear
Error
Start
Lamp
5.5.
Repair ELC
Only the manufacturer is permitted to repair the ELC. In case of failure please contact the