3. Installation
page 19
ELC PE22B-PE35B V1.0-05.19-GB
Subject to technical alterations
3.5.3.
Setting lamp power via PROFIBUS
PROFIBUS-output-data (Master
→
ELC)
Byte-
No.
0
1
2
3
4
5
Name
[Power
Set
Value]
[Installed
Lamp
Power]
[Lamp
Control]
[User
Register]
The set value for lamp power has to be written into the register
[Power Set Value]
.
The ELC’s
output power is defined by the control characteristic of Fig. 8.
Fig. 8:
Control characteristic
The lamp power can be set in steps of 32 W.
The ELC’s nominal
power is written into the register
[ELC Nominal Power]
of the PROFIBUS-
input-data:
PROFIBUS-input-data (ELC
→
Master)
Byte-
No.
0 1 2 3
4
5
6
7
8
9
10 11 12 13 14
15
Name
[ELC
Serial
Number]
[Software
Version]
[ELC
Nominal
Power]
[Error
Register]
[Warning
Register]
[Lamp
Status]
[Actual
Power]
[Actual
Voltage]
[Actual
Current]
[Reserved]
Lamp power
ELC-nominal-
power
20% ELC-nominal-power
[Power Set
Value]
20% ELC-nominal-power
ELC-nominal-
power
Lamp power
ELC-nominal-
power
20% ELC-nominal-power
[Power Set
Value]
20% ELC-nominal-power
ELC-nominal-
power