27
If you use the direct connect method, be sure that there is no power flowing through the target conductor.
If you use the Metroclamp on energized lines, follow established safety procedures.
5.15 Distribution Systems
To locate short gas services on a gas distribution system, you should temporarily ground the end of the
service. This can be accomplished by temporarily connecting a jumper cable to a ground spike at the end
of a service, where the pipe or tracer wire comes out of the earth. Be sure to remove the ground connection
after completing the locate so as not to defeat the cathodic protection system.
6 MAINTENANCE
The only routine maintenance required for the Model 480B equipment and accessories is to test and
replace, if necessary, the batteries in the transmitter and the receiver. Both possess battery test features,
making it easy to check the condition of the batteries at any time.
We recommend checking the transmitter and receiver batteries before each use, preferably before leaving
for the job site.
6.1 Checking and Replacing the 480B Transmitter and Receiver Batteries.
Check and replace the Transmitter and Receiver batteries as follows:
1 Have ready 6 C Cell batteries.
2 To test the Transmitter batteries, pull the power switch on. The LED will blink steadily if the batteries
are in good condition. It will begin to slow down as the batteries lose power. If it does not blink at all, the
batteries need to be replaced.
3 To test the Receiver batteries, turn the Range Knob to "NORM". The needle on the field strength
indicator should move into the BATT test area. If it does not, the batteries need to be replaced.
4 To replace batteries in either the Transmitter or the Receiver, open the BATTERY ACCESS door on the
front of the unit. Extract the battery holder and replace batteries, positioning according to the indications
shown inside the battery holder.
5 Close the battery access panel, ensuring that there are no wires caught between the receiver body and the
access panel. Make sure the latch is securely fastened.
6.2 Basic Preventive Maintenance
The Model 480B is designed for rugged outdoor use, but rough handling should be avoided. Keep the
equipment dry, clean, and free of grit.
Service Center Information
If the equipment does not function properly, replace or recharge the batteries as described in the
sections above. If the equipment still malfunctions, contact a Metrotech Customer Service Center.