1. The pump cord is not properly plugged into
the control unit.
2. The primary switch has failed.
3. The Smart Charger is damaged. This could
be caused by a jammed impeller, or motor
overheating.
4. The motor is damaged.
5. The brushes are worn out. This would most
likely occur in an older unit.
See Figure H
.
Screen Seven.
This means that the auxiliary
alarm/pump switch has activated. When this
occurs one of two things is happening:
1. The main pump switch has failed.
2. The water is coming into the basin faster than
the pump can pump it out. This scenario will
sound a continuous
beeping alarm. This
may also be caused by a depleted battery in
the DC mode. Turn on the pump and check
% of battery life left.
CONTINUOUS
BEEPING
WARNING! HIGH
WATER ALERT
This completes the operating scenarios of the
SUMP BOSS
system. As you can see, this
product was designed to be extremely user-friendly and should always warn and assist
you in resolving any problems that may occur during the life of this product.