Sump Boss
Metropolitan Industries, Inc.
www.metropolitanind.com
OPERATION MANUAL
Dated: 9/17/09
Supersedes: None
Document No.: SBossO&M
Page 11 of 19
Register your product at
www.sumpro.com
OPERATION OF THE SUMP BOSS &
“SMART CHARGER” SYSTEM.
SUMP BOSS TESTING
AND OPERATION
The SUMP BOSS Battery Pump System
is the most advanced system on the
market today. Its microprocessor-based
“Smart Charger” system, coupled with
the LCD display and alarm, allows it to
tell you in what state the system is at all
times. The following is a step-by-step
description of the LCD screens and alarm
codes for the system during normal AC
operation as well as during DC operation.
1. Unplug your primary pump and fill the pit
with water until the SUMP BOSS starts
pumping.
2. Check to make sure that the pump turns
on and off at the desired levels. If it
does not, adjust the rubber stops on the
float rod by sliding them up or down to
achieve the desired level. Figure G.
3. Manually lift the float on the
Auxiliaryalarm/pump switch to make
sure it is properly set and working. If this
switch needs further adjustment, loosen
the hose clamp on the bracket and slide
it up or down on the discharge pipe and
re-tighten it at the desired level.
NOTE: During the testing you will hear the
alarm sound. This is normal and will be ex-
plained in the next section.
CAUTION: DO NOT RUN THE PUMP
DRY! SERIOUS DAMAGE MAY OCCUR!
Always make sure there is sufficient water
in the basin before running the pump.