The following steps describe how to properly install the cables for an OCIA Stratos
E
application. The scanner must
then be configured to match the host’s OCIA parameters. Cable installation alone does not guarantee that the Stratos
E
will communicate properly with the host system.
Configuration bar codes are located in the MetroSelect Configuration Guide (
MLPN
00-02407
x
) and the
MS2
xxx
Stratos Series Configuration Addendum (
MLPN
00-02034
x
).
1. Turn off the host system.
2. Plug the 10-Pin RJ45 end of the OCIA interface cable (
MLPN
57-57015x-N-3) into the 10-pin socket labeled
Scanner OCIA to Host
.
3. Connect the other end of the OCIA interface cable to the appropriate communication on the host device.
Before continuing verify that the OCIA interface cable is connected to the appropriate interface jack on the scanner.
An incorrect cable connection can cause communication problems or potential damage to the scanner.
Manufacturers Note:
Plugging the scanner into the serial port of the host device does not guarantee that scanned information will
appear at the host device. A software driver and correct configuration settings are also required for proper
communication to occur.
4. Plug the external power supply into the 3-pin Molex socket labeled,
DC Power In
, on the bottom of the Stratos
E
.
Check the AC input requirements of the power supply to make sure the voltage matches the AC outlet.
The outlet should be located near the equipment and be easily accessible.
Metrologic recommends using a switched AC outlet. The switch should be located on the operator’s side of the
checkout counter in close proximity to the Stratos
E
to facilitate service of the unit.
5. Connect AC power to the transformer. If the AC outlet is equipped with an on/off switch, turn the power on.
6. Turn on the host system.
7. Configure the Stratos
E
to match the host system’s OCIA parameters.
Refer to the MetroSelect Configuration Guide (
MLPN
00-02407x) under
Section I: OCIA for Enabling and Setting
OCIA Parameters,
Load OCIA Defaults
.
Figure 21. OCIA Cable Installation Schematic
See power source caution statement on page 8 of this manual.
Содержание StratosE MS2122
Страница 1: ...METROLOGIC INSTRUMENTS INC MS2122 StratosE Installation and User s Guide...
Страница 34: ...30 MAINTENANCE VERTICAL SCAN WINDOW REPLACEMENT Figure 38 Vertical Scan Window Replacement...
Страница 51: ...47 PATENTS Patent Information For patent information please refer to www honeywellaidc com patents...
Страница 52: ...48...
Страница 55: ......
Страница 56: ...March 2008 0 0 0 2 0 2 8 C...