Diagnostic Indicator Display
There is a two-digit error code display located under the platter near the bottom right corner of the output window (see figure
below).
Figure 32. Diagnostic Indicator Display
The following is a list of possible error codes and their meanings. Some errors will require immediate scanner maintenance.
Error
Code
Description
01 Reserved
02
RAM ERROR – The scanner’s Random Access Memory (RAM) is tested as faulty. Return the unit for repair at an
authorized service center.
03
PROGRAM ERROR – The scanner’s software program is failing. Return the unit for repair.
04
INTERFACE ERROR – After power up and any application exit (e.g. MetroSet, etc.), the scanner checks the
interface hardware with that chosen in configuration. If they do not agree, an interface error exists. Correct this
problem by getting the proper hardware interface OR by configuring the Stratos
E
for the proper interface
hardware attached.
05
CONFIGURATION ERROR – The non-volatile configuration memory did not agree with the data last saved.
Default configuration data is then used and the scanner continues operating. This error is also accompanied by 3
beeps. This error will remain during operation as a reminder that this power cycle is scanning against a default-
generated configuration.
06
COMMUNICATION ERROR - The RS232 data line is being held active. This causes the scanner to read a
“break” signal constantly and continuous attempts are made to enter MetroSet configuration mode. A short on
the RX Data line can cause this condition. It can also be the result of a laptop in power save mode. The scanner
will abort attempts to enter configuration mode after a short timeout. The scanner can automatically recover from
this condition once the short in the RX Data line is corrected.
09
COPROCESSOR COMMUNICATION ERROR – The main microprocessor is not communicating with the
interface coprocessor. The interface coprocessor may be in a fault condition with the host or just not able to
respond. This error may appear when the scanner is configured for USB or IBM interface applications or during
an attempt to update the interface software through the flash utility. The unit should be repaired at an authorized
service center.
11
SWITCH ERROR – The switch used for volume selection or sleep mode is detected in error (always closed).
The condition is self-correcting if possible. If the error persists, return the unit for repair at an authorized service
center. The scanning operation can continue with this error active.
Содержание StratosE MS2122
Страница 1: ...METROLOGIC INSTRUMENTS INC MS2122 StratosE Installation and User s Guide...
Страница 34: ...30 MAINTENANCE VERTICAL SCAN WINDOW REPLACEMENT Figure 38 Vertical Scan Window Replacement...
Страница 51: ...47 PATENTS Patent Information For patent information please refer to www honeywellaidc com patents...
Страница 52: ...48...
Страница 55: ......
Страница 56: ...March 2008 0 0 0 2 0 2 8 C...