Locations:

USA Corporate Headquarters

Europe

Metrologic Instruments, Inc. 

Metrologic Instruments GmbH

Blackwood, NJ 08012

Munich, Germany

Customer Service: 1-800-ID-METRO

Tel:  49-89-89018-0

Tel:  609-228-8100

Fax:  49-89-89019-200

Fax:  609-228-6673

ASIA

South America

Metrologic Asia (PTE) Ltd.

Metrologic Instruments 

Singapore 417818

CEP 04571-090, São Paulo-SP, Brasil

Tel: 65-842-7155

Outside Brazil:

Fax: 65-842-7166

Tel: 55-11-5505-6568
Fax: 55-11-5505-1681
In Brazil:
Tel: 55-11-5505-2396
Fax: 55-11-5507-2301

Copyright

© 1998 by Metrologic  Instruments, Inc. All rights reserved. No part of this work may

®

be reproduced, transmitted, or stored in any form or by any means without prior written
consent, except by reviewer, who may quote brief passages in a review, or provided for
in the Copyright Act of 1976.

Products and brand names mentioned in this document are trademarks of their
respective companies.

Содержание IS4320 ScanGlove

Страница 1: ...METROLOGIC INSTRUMENTS INC IS4320 ScanGlove Programming Guide MLPN 2405 Printed in USA April 1998 ...

Страница 2: ...o Paulo SP Brasil Tel 65 842 7155 Outside Brazil Fax 65 842 7166 Tel 55 11 5505 6568 Fax 55 11 5505 1681 In Brazil Tel 55 11 5505 2396 Fax 55 11 5507 2301 Copyright 1998 by Metrologic Instruments Inc All rights reserved No part of this work may be reproduced transmitted or stored in any form or by any means without prior written consent except by reviewer who may quote brief passages in a review o...

Страница 3: ...ce 8 RS 232 Parameter Baud Rate 8 9 RS 232 Parameter Parity 10 RS 232 Parameter Data Bits 11 RS 232 Parameter Hardware Handshaking 12 RS 232 Parameter Software Handshaking 13 RS 232 Parameter Intercharacter Delay 14 RS 232 Parameter Scanning Control DTR Signal 15 Record Header Terminator Select 15 17 RS 232 Parameter UPC EAN Identifiers 18 Light Pen Options 19 Code Type Selections 20 21 Minimum Co...

Страница 4: ...tions 24 Supplemental UPC Options 25 Code 39 26 27 Codabar 27 Interleaved 2 of 5 ITF 28 Interleaved 2 of 5 ITF Symbol Lengths 29 32 MSI Plessey Check Digit 32 33 Test Modes 34 Special Features 35 36 Reserved Codes 37 41 Disclaimer 42 Index 43 44 ...

Страница 5: ... PROGRAM MODE bar code The unit will beep three times 3 Scan by positioning the output window within two inches of each code When you scan the first menu selection the laser will stay on until you scan the ENTER EXIT PROGRAM MODE code again If no scanning occurs for 30 seconds while the scanner is in program mode the unit will beep three times and all changes made will be lost If this occurs retur...

Страница 6: ...canner on First Scan will only enter program mode after power up Scan the ENTER EXIT PROGRAM MODE bar code immediately after the scanner first receives power This option prevents the scanner from accidentally entering program mode during normal scanning operation Recall Defaults If during programming of the scanner there is a need to return the scanner to the original factory settings scan the REC...

Страница 7: ...is option is selected the IR In the Stand sensor guarantees to activate when an object is presented three inches from the scanning window Long Range Activation When this option is selected the IR Out of the Stand sensor guarantees to activate when the scanning window is positioned eight inches from the object Long Range Activation When this option is selected the IR In the Stand sensor guarantees ...

Страница 8: ...ontal line until it senses a bar code or until the scanner timeout elapses Pulsing Scan When the laser activates by the IR sensor the laser beam will emit from the output window It will also display a pulsing horizontal line until it senses a bar code or until the scanner timeout elapses Custom Scan This option is available for special applications Do not scan the CUSTOM SCAN bar code unless instr...

Страница 9: ... symbol Short Same timeout For SHORT SAME SYMBOL RE SCAN Symbol Re Scan the time delay is second while the LONG SAME SYMBOL RE SCAN delay is 1 second These numbers represent the amount of time that a bar code must be out of the scan field before it can be scanned again Long Same Symbol Re Scan ...

Страница 10: ...Exit Program Mode 6 Beeper Tones Program the scanner to emit a certain tone Alternate Tone 1 Low Tone Alternate Tone 2 High Tone Default Alternate Tone 3 Medium Tone No Tone Alternate Tone 1 Alternate Tone 2 Alternate Tone 3 No Tone ...

Страница 11: ... of hand shaking is involved No Two Second Timeout Razz Beep on Timeout When this option is selected The scanner will produ ce an audible razzberry tone when communications timeout No Tone After Timeout Three Beep on Timeout When this option is selected the scanner will beep three times when communications time out Beep Before Transmit When this option is selected the scanner will beep before each...

Страница 12: ...terface RS 232 Parameter Baud Rate A baud rate is a unit that measures the speed with which information transfers The baud rate of the scanner must equal the baud rate of the host device The available baud rates range from 150 to 19200 150 Baud Rate 300 Baud Rate 600 Baud Rate 1200 Baud Rate ...

Страница 13: ...D F 1 B R 5 B R 6 B R 7 B R 8 Recall Defaults 9 2400 Baud Rate 4800 Baud Rate 9600 Baud Rate 19200 Baud Rate ...

Страница 14: ... must match the host s parity Space Parity Select this option to make the parity bit always 0 Even Parity Select this option to make the additional parity bit either a 0 or 1 to guarantee an even number of bits Mark Parity Select this option to make the parity bit always 1 Odd Parity Select this option to make the additional parity bit either a 0 or 1 to guarantee an odd number of bits ...

Страница 15: ...er Data Bits RS 232 serial communication requires ASCII data to 8 Data Bits transmit in either 7 or 8 data bits In addition one parity bit will transmit If necessary scan the appro priate bar code that matches your host device s requirements 7 Data Bits ...

Страница 16: ...an RTS signal and wait for a CTS signal before any data transmits The default setting of RTS CTS disables If necessary scan the ENABLE RTS CTS bar code Disable RTS CTS Character RTS CTS When this option is selected the scanner will activate and deactivate its RTS signal on each character that it transmits Message RTS CTS When this option is selected the scanner will activate and deactivate its RTS...

Страница 17: ...K When this option is enabled the Enable ACK NAK scanner will not scan again unless after transmission of a bar code it receives an ACK ASCII 06H The scanner will retransmit the bar code if it receives an NAK ASCII 15H Disable ACK NAK XON XOFF When this option is enabled the Enable XON XOFF scanner will stop transmission whenever it receives an XOFF ASCII 13H Transmission will resume after it rece...

Страница 18: ...racter delay bar code represents the interim of time between transmission of characters Some host systems require this delay when receiving transmissions If necessary scan the appropriate bar code No Intercharacter Delay 1 Millisecond Intercharacter Delay 5 Millisecond Intercharacter Delay 25 Millisecond Intercharacter Delay ...

Страница 19: ...ble the scanner by making DTR inactive 12V at the DTR input pin The DTR Scan Disable feature will prevent any Disable DTR Input scanning when the Enable DTR input feature is chosen Before enabling the Enable DTR Scan Disable feature scan the Enable DTR Input bar code To turn off this feature scan the Recall Defaults bar code Enable DTR Scan Disable Record Header Terminator Select CR When this opti...

Страница 20: ...am Mode 16 LF When this option is on the scanner will transmit a Line Feed after each bar code LF On LF Off STX Prefix When this option is on the scanner will transmit a Start of TeXt ASCII 02H before each bar code STX Prefix On STX Prefix Off ...

Страница 21: ...n End of TeXt ASCII 03H after each bar code ETX Suffix On ETX Suffix Off Tab Prefix When this option is on the scanner will transmit a TAB ASCII 09H before each bar code Tab Prefix On Tab Prefix Off Tab Suffix When this option is on the scanner will transmit a TAB ASCII 09H after each bar code Tab Suffix On Tab Suffix Off ...

Страница 22: ...the scanner Prefix ID On will transmit a prefix before any UPC EAN bar code The prefixes are A UPC A E0 UPC E F EAN 13 and FF EAN 8 Prefix ID Off Suffix ID When this option is on the scanner Suffix ID On will transmit a suffix after any UPC EAN bar code The suffixesare A UP C A E0 UPC E F EAN 13 and FF EAN 8 Suffix ID Off ...

Страница 23: ...ace as the high signal Enable the appropriate option for your specific application When the TRANSMIT AS CODE 39 is enabled the scanner will out put the bar code s bar or space high signal as Code 39 These settings will only work with a Version 15 LTPN MS951 scanner Bars High Spaces High Transmit as Scanned Transmit as Code 39 Poll Light Pen 5 Volts When this option is enabled the scanner will wait...

Страница 24: ...he default settings for all of the bar code types To improve reliability disable the code types that will not be used This will not decrease the amount of time it takes for the scanner to scan a bar code It will prevent the operator from accidentally scanning bar code types that are not included in your application Enable UPC Disable UPC Enable EAN Disable EAN Enable Code 39 Disable Code 39 ...

Страница 25: ... I C T J C T G C T H C T K C T L C T M C T N Recall Defaults 21 Enable Codabar Disable Codabar Enable Code 128 Disable Code 128 Enable Code 93 Disable Code 93 Enable Interleaved 2 of 5 Disable Interleaved 2 of 5 ...

Страница 26: ...ied in the bar code that will be scanned by scanning one of the follow ing bar codes For example when the minimum is 3 the scanner will not scan bar codes that have less than 3 characters Minimum 3 Characters Minimum 6 Characters UPC EAN Code UPC and EAN are typical bar code types These Enable UPC enable the default settings for UPC and EAN Disable UPC Enable EAN Disable EAN ...

Страница 27: ...cause duplicate numbers may result in the database when the scanner is programmed not to transmit the UPC A number system character Do Not Transmit UPC A Number Sys UPC A Check Digit On When this option is on the scanner will transmit the UPC A check digit UPC A Check Digit Off Convert UPC A to EAN 13 When this option is selected the scanner will convert UPC A to EAN 13 by trans mitting a leading ...

Страница 28: ...Do Not Expand UPC E UPC E Check Digit On When this option is on the scanner will transmit the UPC E check digit UPC E Check Digit Off UPC E Leading 0 On When this option is on the scanner will output a zero before each UPC E bar code UPC E Leading 0 Off Disable EAN 8 Check Digit Transmission Enable EAN 8 Check Digit Transmission Disable EAN 13 Check Digit Transmission Enable EAN 13 Check Digit Tra...

Страница 29: ...pplementals Disable 5 Digit Supps Convert EAN 8 to EAN 13 When this option is selected the scanner will convert EAN 8 to EAN 13 by trans mitting five zeroes before the bar code Do Not Convert EAN 8 to EAN 13 Enable Bookland When this option is enabled the scanner will require that a 5 digit supplement be scanned whenever an EAN 13 code begins with 978 Disable Bookland Supplement Required When this...

Страница 30: ...able Mod 43 Check Digit When this option this enabled the scanner will only scan Code 39 bar codes that have a Modulo 43 check digit Disable Mod 43 Check Digit Enable Italian Pharmaceutical Disable Italian Pharmaceutical Transmit Mod 43 Check Digit When this option is selected the scanner will transmit to the host the Modulo 43 check digit of Code 39 Do Not Transmit Mod 43 Check Digit ...

Страница 31: ...bled the scanner will scan Codabar bar codes Disable Codabar TransmitStart Stop When this option is selected the scanner will transmit Codabar s start and stop characters before and after each bar code Do Not Transmit Start Stop Enable CLSI Editing When this option is enabled the scanner will perform CLSI library type editing before the information transmits to the host This edit ing only works wi...

Страница 32: ...Check Digit When these options are enabled the scanner will scan ITF bar codes that have a Modulo 10 check digit Disable ITF Check Digit Transmit MOD 10 ITF Check Digit When the transmit option is chosen the scanner will transmit the ITF MOD 10 check character This feature works with the ITF check digit option In order for this feature to work both must be enabled Do Not Transmit MOD 10 ITF Check ...

Страница 33: ... the number of ITF digits in the bar codes that will be scanned by scanning the appropriate bar codes Specify a maximum of two bar code lengths If all of the bar codes that will scan are variable lengths program the scanner to VARIABLE LENGTH Variable Length 2 Digits 4 Digits 6 Digits 8 Digits 10 Digits 12 Digits ...

Страница 34: ... I 1 4 I 1 6 I 1 8 I 2 0 I 2 2 I 2 4 I 2 6 I 2 8 I 3 0 Enter Exit Program Mode 30 14 Digits 16 Digits 18 Digits 20 Digits 22 Digits 24 Digits 26 Digits 28 Digits 30 Digits ...

Страница 35: ...D F 1 I 3 2 I 3 4 I 3 6 I 3 8 I 4 0 I 4 2 I 4 4 I 4 6 Recall Defaults 31 32 Digits 34 Digits 36 Digits 38 Digits 40 Digits 42 Digits 44 Digits 46 Digits ...

Страница 36: ...sey Test of Check Digit When this option is enabled the scanner will check the Plessey bar code for a proper check digit Disable MSI Plessey Test of Check Digit Enable Plessey Mod 10 Check Digit When this option is enabled the scanner will scan Plessey bar codes that have a single Modulo 10 check digit Plessey Mod 10 10 Check Digit When this option is selected the scanner will scan Plessey bar cod...

Страница 37: ...ransmit Plessey s check digit s character This option works with the Plessey Mod 10 and or Plessey Mod 10 10 features Enable this option and one or both of the Plessey Mod options in order for this feature to work Do Not Transmit Plessey Check Digits Enable Code 11 Decode Disable Code 11 Decode Enable Airline 2 of 5 Disable Airline 2 of 5 ...

Страница 38: ... a Metrologic representative instructs you to do so Scannability When this option is enabled the scanner will enter the scannability test mode Do not enable this feature unless a Metrologic representative instructs to do so Normal Scan When this option is selected the scanner will exit from the scannability or scan count test modes Transmit Scanner Parameters When this option is selected the scann...

Страница 39: ...s are for special applications Do not enable any of the special features options unless instructed by a Metrologic representative Disable Sanyo 635 ECR Protocol Enable Sanyo 635 ECR Protocol Enable Post Software ID Characters Disable Post Software ID Characters Enable NEWCODE Mode A Disable NEWCODE Mode A ...

Страница 40: ...e it is by scanning the Recall Defaults bar code Enable Caps Lock Mode Enable this option when using the Caps For the MI951 external wedge Lock on the keyboard Once enabled Metrologic s MS951 RS 232 hand held scanner will simulate Caps Lock keyboard input when used with Metrologic s MI951 external keyboard wedge This mode may not work with all applications Disable Caps Lock Mode Enable French Wyse...

Страница 41: ... R 2 8 R 2 9 R 3 3 R 3 4 R 3 5 R 4 0 Recall Defaults 37 Reserved Codes Metrologic has reserved the codes on the following pages for features that will be added at a later date Do not assign a function for any of the reserved codes ...

Страница 42: ... R 4 8 R 4 9 R 6 0 R 6 1 R 6 2 R 6 3 R 6 8 R 6 9 R 7 0 R 7 1 R 7 2 Enter Exit Program Mode 38 ...

Страница 43: ...D F 1 Recall Defaults 39 R73 R74 R75 R76 R77 R78 R79 R80 R81 R82 R83 ...

Страница 44: ... R 8 4 R 8 5 R 8 6 R 8 7 R 8 8 R 8 9 R 9 0 R 9 1 R 9 2 R 9 3 R 9 4 Enter Exit Program Mode 40 ...

Страница 45: ...D F 1 R 9 5 R 9 6 R 9 7 R 9 8 Recall Defaults 41 ...

Страница 46: ...hr und haften nicht für die Richtigkeit im Hinblick auf Inhalt oder Genauigkeit der Angaben dieser Veröffentlichung oder des hierin beschriebenen Produkts Sie übernehmen ebenso keinerlei Eignungsgarantie oder Gewährleistung durchschnittlicher Qualität für einen bestimmten Zweck Alle benannten oder ausdrücklichen Zusicherungen schließen sämtliche Verpflichtungen oder Haftungen aus jeglichem Schaden...

Страница 47: ...Code 11 33 Code 128 21 Code 39 20 26 full ASCII 27 mod 43 check digit 26 transmit mod 43 check digit 26 Code 93 21 Code Length 22 Custom Scan 4 D Data Bits 11 DTR input 15 scan disable 15 E EAN 20 22 EAN 13 check digit 25 EAN 8 check digit 25 EAN 8 to EAN 13 25 ETX Suffix 17 Europe ii F French Wyse 120V PC Term 36 G Headquarters ii I L Laser long range activation 3 short range activation 3 Light P...

Страница 48: ...RS 232 8 RTS CTS 12 S Same Symbol Re Scan 5 Sanyo 635 ECR Protocol 35 Sineko Mode 36 SNI Beetle Mode 36 South America ii STX Prefix 16 Suffix ID 18 Supplemental 2 digit 25 5 digit 25 required 25 T Tab prefix 17 suffix 17 Test Modes normal scan 34 scan count 34 scannability 34 transmit scanner parameters 34 Timeout razz beep 7 three beep 7 two second 7 UPC 20 22 UPC A check digit 23 convert to EAN ...