![Metrologic IS421X ScanGlove Скачать руководство пользователя страница 6](http://html1.mh-extra.com/html/metrologic/is421x-scanglove/is421x-scanglove_installation-and-user-manual_1779737006.webp)
3
Connecting the IS4210 or IS4213 ScanGlove to a
Decoder/Controller
Important Note:
To maintain compliance with applicable standards, all
circuits connected to the scanner must meet the requirements for SELV (Safety
Extra Low Voltage) according to EN 60950.
Since each host system is unique, configure the decoder/controller to match
your host system requirements. Refer to the Installation and User’s Guide for
further information.
Since there are many different types of decoders, refer to your decoder’s
documentation to connect the decoder to your host system.
1.
Make sure the host system is off and the ON/OFF toggle switch on the
controller is in the OFF (O) position.
2.
Connect the 9-pin squeeze end of the scanner adaptor cable to the
decoder/ controller. Then, attach the 15-pin connector of the host’s
communication cable to the decoder/controller. Connect the other end
of the cable to the host device.
3.
If the decoder/controller receives power from an external power supply,
check the AC input requirements of the transformer/power supply to
make sure the voltage matches an available AC outlet. Connect the
power supply to the decoder/controller. (The socket-outlet can be
installed near the equipment so it will be easily accessible.)
4.
Supply power to the scanner and decoder/controller by plugging the
power supply into the AC outlet. Position the decoder ON/OFF switch
to the ON (1) position and then power up the host system.
Note:
When the ScanGlove first receives power, it will immediately go
through a self diagnostic routine, then the red and green LED will
flash and the unit will beep once.
When positioning the ScanGlove, make sure to align the output
window flush with the knuckles of your hand. Also, avoid
obstructing the output window. Rings and fingers may prevent the
scanner from reading a bar code.