background image

19

Appendix C

Warranty and Disclaimer

Limited Warranty

Products manufactured by Metrologic have a 2-year limited warranty from date of
manufacture.

This warranty is limited to repair, replacement or refund at Metrologic’s discretion.
Faulty equipment must be returned to the Metrologic facility in Blackwood, New Jersey
or Puchheim, Germany. To do this, contact Metrologic Customer Service/Repair for a
Returned Material Authorization (RMA) number.

In the event that it is determined that the equipment failure is covered under the
warranty, Metrologic shall, as its sole option, repair, replace with a functionally
equivalent unit, or refund an amount equal to the purchase price to the original
purchaser, whether distributor, dealer/reseller, or retail consumer, and return the
equipment to the customer without charge for service or return freight.

This limited warranty does not extend to any Product which, in the sole judgement
of Metrologic, has been subjected to misuse, neglect, improper installation or
accident, nor does it extend to any Product which has been repaired or altered by
anyone who is not a Metrologic authorized representative. 

THIS LIMITED WARRANTY, EXCEPT AS TO TITLE, IS IN LIEU OF ALL
OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING
MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR PURPOSE,
ARISING BY LAW, CUSTOM OR CONDUCT. THE RIGHTS AND
REMEDIES PROVIDED HEREIN ARE EXCLUSIVE AND IN LIEU OF ANY
OTHER RIGHTS OR REMEDIES. IN NO EVENT SHALL METROLOGIC BE
LIABLE FOR INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES,
INCLUDING, WITHOUT LIMITATION, ANY INJURY TO PROPERTY OR
PERSON OR EFFECT ON BUSINESS OR PROFIT, AND IN NO EVENT
SHALL ANY LIABILITY OF METROLOGIC EXCEED THE ACTUAL
AMOUNT PAID TO METROLOGIC FOR THE PRODUCT.

Metrologic Instruments, Inc.

Customer Service Department 

90 Coles Road

1-800-ID-METRO (1-800-436-3876)

Blackwood, NJ 08012

TEL: 609-228-8100
FAX: 609-228-6673

Metrologic Instruments GmbH
Dornierstrasse 2
82178 Puchheim b.
Munich, Germany
TEL: 49-89-89019-0 
FAX: 49-89-89019-200

Содержание IS421X ScanGlove

Страница 1: ...METROLOGIC INSTRUMENTS INC IS421X ScanGlove Laser Bar Code Scanner Installation and User s Guide MLPN 2187 Printed in USA October 1998...

Страница 2: ...Brooklin 05 08 Techlink CEP 04571 090 S o Paulo SP Brasil Singapore 417818 Outside Brazil Tel 65 842 7155 Tel 55 11 5505 6568 Fax 65 842 7166 Fax 55 11 5505 1681 ant888 cyberway com sg info sa metrol...

Страница 3: ...canner 4 Audible Indications 5 Visual Indications 6 9 Labels 10 IR Sensor Activation 11 Scan Field 11 Depth of Field and Symbol Specification 12 Maintenance 13 Appendix A Specifications 14 Appendix B...

Страница 4: ...er operation is dependent upon your decoder Since there are many decoders available refer to the decoder s documentation concerning scanner requirements and operation Unpacking List With the purchase...

Страница 5: ...w out to approximately 4 to 7 Long Range Activation The IR signal initiates the scan process if it senses an object anywhere from the face of the window out to approximately 9 to 13 If the object is r...

Страница 6: ...mmunication cable to the decoder controller Connect the other end of the cable to the host device 3 If the decoder controller receives power from an external power supply check the AC input requiremen...

Страница 7: ...hows that the scanner has read a bar code successfully When the green light turns off communication to the host is complete Output Window Sends and receives the IR signal and Laser beam Infrared If a...

Страница 8: ...eives power the red LED will blink followed by the green LED and then the scanner will beep After the scanner performs this start up sequence the scanner is ready to scan When the scanner successfully...

Страница 9: ...red LED Green Flash will flash followed by the green LED and then beep Steady Red once After the scanner performs this startup sequence the red LED will remain on for a specified time show ing that th...

Страница 10: ...clignotante diode verte clignotante diode rouge restant allum e Quand le scanner re oit pour la premi re fois de l nergie la diode rouge se met d abord clignoter puis la diode verte Ensuite le scanner...

Страница 11: ...Scanner erstmalig Energie zugef hrt wird blinkt zun chst die rote Leuchtdiodenanzeige auf gefolgt von der gr nen Leuchtdiodenanzeige und anschlie end sendet der Scanner ein einmaliges Piep Signal aus...

Страница 12: ...diodo l uminoso verde acceso Quando lo scanner viene alimentato per la prima volta lampeggia dapprima il diodo luminoso rosso e quindi quello verde Poi lo scanner emette un unico segnale beep Dopo l...

Страница 13: ...ure laser light emitted from this aperture label is located directly over the output window Below are examples of these labels Caution For the scanner to comply with IEC 825 as a Class 1 laser product...

Страница 14: ...cts extends approximately 9 13 beyond the output window The IR sensor remains active as long as power is applied to the unit The mode wanted can be manually enabled by repositioning the Short Range Lo...

Страница 15: ...80 1 5 5 5 UPC EAN 13 0 100 1 5 6 0 Code 39 7 5 High 1 5 4 0 Code 39 12 0 Medium 2 5 5 5 Code 39 21 0 Low 3 0 6 5 I 2 of 5 7 5 High 1 5 4 0 I 2 of 5 12 0 Medium 3 0 5 5 I 2 of 5 21 0 Low 2 5 6 0 Codab...

Страница 16: ...es and dirt can interfere with the proper scanning of a bar code Therefore the output window will need occasional cleaning 1 Spray glass cleaner onto lint free non abrasive cleaning cloth 2 Gently wip...

Страница 17: ...ional Depth of Field UPC 100 38 1 mm to 139 7 mm 1 5 to 5 5 Scan Speed 70 scan lines per second Scan Pattern Single scan line Maintenance Clean output window periodically Print Contrast 35 minimum ref...

Страница 18: ...polarity does not show scan direction This open collector output can sink 25 mA via an external pull up resistor connected to a voltage not to exceed 20 VDC 2 Data Data is an output digital represent...

Страница 19: ...ign of this scan head to have the continual enabling of the laser as if the scanner is in a perm anent mounting fixture 6 Laser A 5 VDC input to the head Its use is to start Motor Control the flipper...

Страница 20: ...y laser diode motor power input 5 VDC should be present at this pin and it can supply up to 125 mA when enabled by the signal at pin 6 20 No Connect 23 Proximity Detect The proximity detect is a groun...

Страница 21: ...econd which equals 70 scans per second Note The polarity does not show scan direction This is an open collector output that can sink 25 mA via an external pull up resistor connected to a voltage not t...

Страница 22: ...ich in the sole judgement of Metrologic has been subjected to misuse neglect improper installation or accident nor does it extend to any Product which has been repaired or altered by anyone who is not...

Страница 23: ...nd haften nicht f r die Richtigkeit im Hinblick auf Inhalt oder Genauigkeit der Angaben dieser Ver ffentlichung oder des hierin beschriebenen Produkts Sie bernehmen ebenso keinerlei Eignungsgarantie o...

Страница 24: ...ard Remarque Apr s contr le de cet appareil on a not qu il r pondait aux valeurs limites de la classe A c onform ment la partie 15 des directives de l administration f d rale am ricaine pour les t l c...

Страница 25: ...en Der Einsatz optischer Ger te mit dieser Laserausr stung erh ht das Risiko einer Sehsch digung N B Dal controllo di questo apparecchio risulta che esso risponde ai valori limite per apparecchi digit...

Страница 26: ...053 5 396 055 5 408 081 5 410 139 5 436 440 5 449 891 5 468 949 5 479 000 5 532 469 5 545 889 5 742 043 and 5 756 982 No license right or sublicense is granted either expressly or by implication esto...

Страница 27: ...mer Service ii 19 D Depth of Field 11 12 14 Dimensions 14 Disclaimer 20 E Electrical 14 Email ii Environmental 14 ESD 14 Europe ii External Power Supply 3 F Faulty equipment 19 Fax ii G Germany GmbH i...

Страница 28: ...14 P Weight 14 Parts 4 Patents 23 Pin assignments 15 18 Power supply 3 Print contrast 14 Programming guide 5 R Red LED 3 6 Repair 19 Rights property 23 warranty 19 RMA 19 Roll pitch yaw 14 S Scan fiel...

Отзывы: