background image

 

 

IS1000  –  Installation and User’s Guide 

7

2.6. Part 

Numbers 

 

Metrologic Part Number 

Description 

IS1000 EC KIT 

-  Standard Laser Reader 
- Radio Base 
-  Battery Charger with EC 5V power supply 
- Holster 

IS1000 UK KIT 

-  Standard Laser Reader 
- Radio Base 
-  Battery Charger with UK 5V power supply 
- Holster 

IS1000 IND EC KIT 

-  Standard Laser Reader 
-  Industrial Radio Base (IP65) 
-  Battery Charger with EC 5V power supply 
- Holster 

IS1000 IND UK KIT 

-  Standard Laser Reader 
-  Industrial Radio Base (IP65) 
-  Battery Charger with UK 5V power supply 
- Holster 

IS1100 EC KIT 

-  Long Range Laser Reader 
- Radio Base 
-  Battery Charger with EC 5V power supply 
- Holster 

IS1100 UK KIT 

-  Long Range Laser Reader 
- Radio Base 
-  Battery Charger with UK 5V power supply 
- Holster 

IS1100 IND EC KIT 

-  Long Range Laser Reader 
-  Industrial Radio Base (IP65) 
-  Battery Charger with EC 5V power supply 
- Holster 

IS1100 IND UK KIT 

-  Long Range Laser Reader 
-  Industrial Radio Base (IP65) 
-  Battery Charger with UK 5V power supply 
- Holster 

IS1000 

Standard Laser Reader 

IS1100 

Long Range Laser Reader 

98-983431 Radio 

Base 

98-983432 

Industrial Radio Base (IP65) 

98-983524 

EC 12V power supply for Radio Base 

98-983525 

UK 12V power supply for Radio Base 

98-983435 

Battery Charger with EU 5V power supply 

98-983527 

Battery Charger with UK 5V power supply 

98-983439 Holster 
98-9834xx 

Battery Charger Mounting Plate 

52-52806A RS232 

Cable 

DB9 

52-52801A RS232 

Cable 

DB25 

52-52802A 

Keyboard-Wedge PC Cable 

 

Содержание IS1000 Series

Страница 1: ...IS1000 Series Radio Frequency Bar Code Reader Installation and User s Guide Metrologic Instruments GmbH Dornierstrasse 2 82178 Puchheim GERMANY Tel 49 0 89 890 19 0 Fax 49 0 89 890 19 200...

Страница 2: ......

Страница 3: ...ll not be held liable for any direct or indirect losses or damage resulting from its use Moreover Metrologic Instruments GmbH reserves the right to modify its products entirely or in part at any time...

Страница 4: ...Julian Camarillo 29 D1 Bajo 28037 Madrid SPAIN Tel 34 91 327 24 00 Fax 34 91 327 38 29 Metrologic Eria Ib rica S A Consell de Cent 106 108 3 3a 08015 Barcelona SPAIN Tel 34 93 423 11 10 Fax 34 93 423...

Страница 5: ...e Host 12 4 2 1 Examples of Connections 12 4 2 2 Connection Procedure 13 4 3 Linking the Laser Reader to the Radio Base 13 4 4 Programming the Communication Mode 14 4 5 Programming Bar Code Symbologie...

Страница 6: ...IS1000 Installation and User s Guide iv 9 TROUBLESHOOTING GUIDE 31 10 LASER APPENDIX 33 10 1 Safety 33 10 2 Labeling 33 11 BATTERY APPENDIX 35 12 CE CONFORMANCE 37...

Страница 7: ...gned for the logistics transportation manufacturing and retail sectors The IS1000 includes a laser reader and a radio base providing the interface with the host or fixed terminal Many communication in...

Страница 8: ...IS1000 Installation and User s Guide 2 Page intentionally left blank...

Страница 9: ...r and wrist strap Radio base Battery charger and 5V power supply unit Holster and hardware The document First Installation and Quick and Easy Set up Bar Code Menu 2 1 Laser Reader The IS1000 laser rea...

Страница 10: ...lable in European and U K versions 2 3 Battery Charger The battery charger is provided with a 5V power supply unit designed for connection to the mains power supply The power supply unit is available...

Страница 11: ...32 Keyboard Wedge OCIA RS485 USB etc and the type of connection connection to a PC a P O S Point Of Sale terminal an IBM 46xx terminal a notebook Refer to Connecting the Radio Base to the Host page 12...

Страница 12: ...IS1000 Installation and User s Guide 6 2 5 2 Battery Charger Mounting Plate Available on order MLPN 98 9834xx...

Страница 13: ...ply Holster IS1100 UK KIT Long Range Laser Reader Radio Base Battery Charger with UK 5V power supply Holster IS1100 IND EC KIT Long Range Laser Reader Industrial Radio Base IP65 Battery Charger with E...

Страница 14: ...IS1000 Installation and User s Guide 8 Page intentionally left blank...

Страница 15: ...etc 3 2 Installing the Battery Charger on a Support The battery charger must be installed on the dedicated mounting plate see page 6 or left free It must not be installed on a vertical or horizontal...

Страница 16: ...IS1000 Installation and User s Guide 10 Page intentionally left blank...

Страница 17: ...between the laser reader and radio base Configure the communication mode Configure the symbologies 4 1 Charging the Battery Connect the laser reader to the charger as shown below read window facing up...

Страница 18: ...re given in The IS1000 Connection List The booklet IS1000 First Installation and Quick and Easy Set up Bar Code Menu for the most common connections 4 2 1 Examples of Connections RS232 Mode PC Keyboar...

Страница 19: ...ector If the radio base uses external power supply unit connect it to the mains power supply which automatically turns on the radio base When the radio base is turned on its red LED lights up and 6 be...

Страница 20: ...0 First Installation and Quick and Easy Set up Bar Code Menu The other modes are described in the IS1000 Configuration Guide Depending on the communication interface other than RS232 it is mandatory t...

Страница 21: ...ctive by default EAN 128 active by default STANDARD 2 5 MSI PLESSEY TELEPEN CODE 93 MATRIX 2 5 IATA BC 412 on request requires IBM s authorization 3W7 Each symbology includes options which may or may...

Страница 22: ...1 short high pitched beep End of charge 1 short high pitched beep Radio base Power on 6 short beeps Message reception OK 1 short beep Start of configuration 1 short beep End of configuration 3 short...

Страница 23: ...ault value is 200 ms When it receives the acknowledgment the laser reader sounds a short high pitched beep transmission OK If it does not receive the acknowledgment the laser reader sounds a long low...

Страница 24: ...ot read another code When it receives the acknowledgment from the host the laser reader sounds a short high pitched beep transmission OK If it does not receive the acknowledgment the laser reader soun...

Страница 25: ...ched beep transmission not OK Then the laser reader waits for acknowledgment from the host during time out T2 whose default value is 3 s During this time out the operator cannot read another code When...

Страница 26: ...nds a long low pitched beep transmission not OK Then the laser reader waits for the BELL character from the host if the bar code is rejected during time out T2 whose default value is 3 s During this t...

Страница 27: ...hen other radio units using the same band cause interference with the IS1000 communication It may also be necessary to change channels when several IS1000 s are used near one another Channel Number Fr...

Страница 28: ...IS1000 Installation and User s Guide 22 Page intentionally left blank...

Страница 29: ...de Reading Code 39 Pharma 32 39 Interleaved 2 5 UPC EAN Monarch Codabar Code 128 EAN 128 Standard 2 5 MSI Plessey Telepen Code 93 Matrix 2 5 IATA BC412 special order 3W7 Interfaces RS232 standard and...

Страница 30: ...r payment of a fee Frequency 433 MHz band European ETS 300 220 standard Channels Selection by bar codes of 6 channels Range Up to 40 meters Environment Operating Temperature 10 C to 50 C Storage Tempe...

Страница 31: ...33 mm 5 1 38 1 cm 20 mils 0 51 mm Up to 53 3 cm 55 mils 1 4 mm Up to 101 6 cm 7 2 2 Long Range Laser Label Density Depth of Field 10 mils 0 254 mm 25 57 cm 15 mils 0 38 mm 20 96 cm 20 mils 0 51 mm 20...

Страница 32: ...Ground 20 DTR Data Terminal Ready 11 TXT Serial TTL Out 18 RXT Serial TTL In 7 3 2 Wand Emulation Pin Number Signal 14 DATA Serial Wand Data 7 GND Electrical Ground 24 DC 5 Volt Output 1 25 DC 5 to 1...

Страница 33: ...SOS Start of Scan 18 GR Good Read 14 TR Trigger 16 EN Enable 24 DC 5 Volt Output 1 25 DC 5 to 14 Volt Input 2 1 A 5volt DC voltage can be provided by the radio base when it is powered by an external...

Страница 34: ...IS1000 Installation and User s Guide 28 Page intentionally left blank...

Страница 35: ...ode RS232 mode 9600 bps Even parity 7 data bits 1 stop bit CR LF end of message characters Symbology Code 39 Interleaved 2 5 UPC EAN Monarch Codabar Code 128 EAN 128 Radio 433 MHz Channel 3 Operating...

Страница 36: ...IS1000 Installation and User s Guide 30 Page intentionally left blank...

Страница 37: ...symbology and check that the reader recognizes the bar code Laser reader not linked with radio base Set up communication between the laser reader and radio base by scanning the radio base ID bar code...

Страница 38: ...IS1000 Installation and User s Guide 32 Page intentionally left blank...

Страница 39: ...version responses 10 1 Safety The laser reader is designed so that there can be no human access to harmful levels of laser during normal operation user maintenance or during prescribed service operati...

Страница 40: ...IS1000 Installation and User s Guide 34 Page intentionally left blank...

Страница 41: ...battery with a capacity of 630 mA H and a life of 500 cycles of use Battery replacement requires return of the laser reader to the shop Safety Do not throw the laser reader in the garbage Do not throw...

Страница 42: ...IS1000 Installation and User s Guide 36 Page intentionally left blank...

Страница 43: ...RMANCE The IS1000 complies with the following standards EMC standard ETS 300 683 1997 edition Radio standard EN 300 220 1 1997 edition Safety standard EN 60 950 1992 edition Laser Safety standard EN 6...

Страница 44: ...IS1000 Installation and User s Guide 38 Page intentionally left blank...

Отзывы: