metrofires LTD Insert Скачать руководство пользователя страница 8

8

This slow combustion appliance is designed to give you 
many years of warmth and service, subject to the following 
key factors. These key factors, if not adhered to are the major 
causes of unsafe installation, poor performance and flue 
blockages and potential product failure.

1.   Your Metro wood fire must be installed correctly. Metro 

recommend a competent and suitably qualified NZHHA 
installer.

2.   The only fuel to be used in this appliance shall be wood that 

meets the following criteria.

–   Less than 25% moisture content
–   Has not been treated with preservatives or impregnated 

with chemicals or glue,

–   Is not chipboard, particle board, or laminated board, 
–  Is not painted, stained or oiled
–  Is not driftwood or other salt impregnated wood

3.   The appliance shall be operated at all times in accordance 

with the “Installation and Operating Instructions” supplied 
with each appliance.

4.   It is preferable that Metro wood fires should be installed with 

a Metro ECO Flue System.

5.   Coal must not be used as a fuel.

Please also note the following important points:

•  In New Zealand a building consent is required from your 

local building authority. The homeowner is responsible for 
obtaining this consent.

•  As correct installation is critical to the performance and safe 

operation of your Metro, it is recommended your Metro be 
installed by a NZHHA registered installer or a person suitably 
qualified in the installation of wood fires. Your Metro retailer 
will be able to arrange professional installation for you.

•  During the very first fire your Metro will give off an odour and 

fumes as the firebox paint cures. Do not be alarmed; open all 
windows and externally opening doors in that room and close 
any internally opening doors. This curing process will last for 
approximately one hour and is likely to happen this one time.

•  Properly seasoned (dry) timber is necessary for the Metro to 

operate efficiently; firewood that contains a high moisture 
content will result in flue pipe blockages, reduce heat 
output and create other issues.

Note: Once split, Softwood usually takes 12 months to season - Hardwood 
can take up to 24 months to season - Wood must be stored in a location 
that enables air circulation. Unseasoned wood stored in a closed 
woodshed without air circulation will still be unseasoned 12 months later.

•    It is critical that the fire not be operated with over worn, 

faulty or missing door seals. Door seals will harden over time 
and become over-worn (3-4 year’s) this will cause air to 
leak into the fire, causing the appliance to ‘over fire’.

•  It is critical that the fire not be operated with over worn, 

faulty or missing bricks, baffle plate, baffle extension 
(white board on the baffle plate)

•  It is critical that the fire not be operated with cracked, or 

broken door glass.

Please note, the above 3 points require regular inspection/
maintenance (every time the ash bed is cleaned out, generally 
3-5 times a season) and if not maintained will void the firebox 
warranty. A glowing firebox or lower fluepipe is just one sign 
you are over firing your appliance. Please ensure you keep your 
proof of purchase/receipt on any parts you purchase.

•  For optimum performance fuel must be loaded so the logs 

lay “front to rear” in preference to laying across the width of 
the firebox. Spaces should be left between the logs to enable 
oxygen to get to as much of the surface of the fuel as possible.

•  A small hot fire loaded frequently is more efficient than a 

large fire burning on a low setting.

•  A key feature of all LTD Metro’s is their ability to burn at a 

very low rate. To familiarise yourself with correct operation 
of this feature, please ensure you read the “extended 
burning” section on page 10 of this manual so as not to 
void the Metro warranty by incorrect operation.

•  Your Metro is covered by a full unconditional 12 month 

warranty on replacement parts, and a 10 year firebox warranty.

• WE HIGHLY RECOMMEND YOU READ THIS ENTIRE 

MANUAL AS INCORRECT OPERATION, MISUSE AND/OR 

LACK OF MAINTENANCE WILL VOID THE WARRANTY

•  Any modification of the appliance that has not been 

approved in writing by the testing authority is considered 
as breaching AS/NZS 4013 and will void the warranty

•  Do not use flammable liquids or aerosols in the vicinity 

of this appliance when it is operating

•  Do not dry clothes on or near this appliance
•  Do not use flammable liquids or aerosols to start or 

rekindle the fire OR store fuel within the Metro’s specified 
installation clearances

•  Never operate your Metro with the door ajar, except on 

initial start up

•  Open the air control fully before opening the Metro’s door

 

WARNING!

 

Important Information

• This appliance should be maintained & operated at all 

times in accordance with this instruction manual

•  This appliance should not be operated with cracked door 

glass, over worn, faulty or missing door seals

•  Do not use driftwood, treated or unseasoned (wet) fuel, 

the use of most types of preservative treated wood as 

fuel can be hazardous and will damage your appliance

• Burning unseasoned (wet) fuel or incorrect operation on 

extended low burn cycles will cause excessive creosote 

to form. Creosote is very corrosive and excessive 

buildups will result in the flue pipe, flue spigot and upper 

burn chamber failing. Failure of the applicance and/

or flue system due to creosote damage is not covered 

under warranty. The formation of such is not an appliance 

issue it is a fuel and operational issue

•  This appliance must be regularly maintained and 

replacement parts must be authorised Metro parts only

•  Do not empty ash into a combustible container

Congratulations on the purchase of your Metro wood fire

 

CAUTION!

 

Important Information

Содержание LTD Insert

Страница 1: ...t information 8 Where to install a Metro in your home 9 Optional wetbacks 9 Getting to know your Metro 10 Operating your Metro 10 11 Cleaning and maintenance 11 12 Troubleshooting 13 Metro warranty 14...

Страница 2: ...ATION MISUSE AND OR LACK OF MAINTENANCE WILL VOID THE WARRANTY The appliance and flue system shall be installed in accordance with AS NZS2918 and the appropriate requirements of the relevant building...

Страница 3: ...of the fascia as detailed in Diagram 2 Carefully lift the ashlip panel away from the fascia and place it gently to one side Remove the four screw s and bottom louvre as illustrated in Diagram 2 Reposi...

Страница 4: ...is packed inverted on top of the firebox and fit it into position over the cabinet sides as detailed in Diagram 1 Ensure the rear edge is fitted correctly as shown in Diagram 1 Inset B The rear edge...

Страница 5: ...nsert will fit It is usually necessary to remove the fire bricks from the lower fireplace cavity The base of the fireplace cavity on which the Metro fireplace insert will rest must be level If it is n...

Страница 6: ...appliance and will void the owners warranty Both 3kW and 4kW wetback options can be fitted to either side of the firebox with the connection pipe heights illustrated in Diagram 4 above please note It...

Страница 7: ...ooking down the chimney if not a stainless steel offset or flexi flue will be required 5 Following the instruction sheet supplied with the flue pack proceed and fit the flue with all joints sealed and...

Страница 8: ...operated with cracked or broken door glass Please note the above 3 points require regular inspection maintenance every time the ash bed is cleaned out generally 3 5 times a season and if not maintaine...

Страница 9: ...he performance of the appliance and void its warranty Note Wetback and Boiler systems are not suitable for use in locations where the water supply has lime content Lime build up inside the coil will e...

Страница 10: ...e a quantity of loosely crumpled newspaper on the base of the firebox until it is approximately 50 full of paper or place firelighters on the base of the firebox Add dry kindling and move the air cont...

Страница 11: ...or similar empty the excess ash directly into a steel or non combustible container If the ash is not disposed of immediately be careful where you store it as the ash can retain heat for many days and...

Страница 12: ...which shows illustrations of the baffle location Cleaning and maintenance for your Metro wood fire Parts guide for your Metro Baffle promet and wetback Listed below are the parts and product codes for...

Страница 13: ...l fitted as standard you will also need to add another 600mm of flue pipe to compensate as the H Cowl is shorter in length Directional Cowl designed for high wind areas Air control setting Ensure the...

Страница 14: ...not being regularly maintained and serviced warranty may be declined It is critical that the fire not be operated with over worn faulty or missing door seals Door seals will harden over time and becom...

Страница 15: ...Detectors Metro Visit us online today www metrofires co nz Metro Wood Fire Specifications Metro have a Specifications Brochure available which details relevant compliance data for every model This br...

Страница 16: ...16...