Radiance CWDM System 25
Technical Specifications
Environmental
Operating Temperature ____________________________________ 0
°
to 50
°
C
Extended Operating Temperature
†
____________________________________________
-40
°
to 80
°
C
Operating Humidity _________________________ 5% to 95% non-condensing
Physical
Physical Case _________________________ Fully enclosed metal construction
Dimensions
Chassis ______________________________ 10.0" L x 17.0" W x 1.72" H
_______________________________ 25.4 cm x 43.2 cm x 4.4 cm
CWDM Module _____________________ 9.812" L x 7.375" W x 1.61" H
______________________ 24.92 cm x 18.73 cm x 4.1 cm
Weight
Chassis ________________________________________ 2.85 lb (1.29 kg)
CWDM Module _________________________________ 1.75 lb (0.79 kg)
Blank Panel ____________________________________ 0.26 lb (0.11 kg)
Network Connections
CWDM Module Fiber Optic Interfaces
Connector _____________________________________________________ SC
Cable Type ____________________________________ 9/125
µ
m singlemode
*
Insertion Loss _____________________________________ 1.0 dBm (OADM)
_________________________ 2.0 dBm (4-channel Mux/Demux)
_________________________ 2.5 dBm (8-channel Mux/Demux)
Wavelengths _____________________ 1310 nm, 1330 nm, 1350 nm, 1370 nm,
_____________________ 1390 nm, 1410 nm, 1430 nm, 1450 nm,
_____________________ 1470 nm, 1490 nm, 1510 nm, 1530 nm,
______________________ 1550 nm, 1570 nm, 1590 nm, 1610 nm
CWDM Transceivers for Radiance Gigabit Line Cards
Connector _____________________________________________________ LC
Cable Type ____________________________________ 9/125
µ
m singlemode
*
RX Input Sensitivity ______________________________ -26 dBm to -24 dBm
Output Power _________________________ 0 dBm to 5 dBm; 2 dBm (typical)
Typical Link Budget __________________________________________ 28 dB
Supported Link Length ________________________________________ 80 km
Wavelength __________________________________ (see tables on next page)
†
Only applicable to the models ending in “E.”
* ITU G.652.C-compliant fiber recommended.