Calculating the Maximum Link Distance

After you have determined the power budget for a fiber link, you can use that
value to calculate the maximum distance the link will support.

Power Budget - Buffer

Distance =

_________________________________

[EQ. 3]

Fiber Attenuation

Typically, a buffer of 2 dBm is subtracted from the power budget to account for
other factors that may affect the loss of transmission power. These factors
include fiber aging, temperature, humidity, poor splices, etc.

Fiber attenuation is the loss of signal strength as it travels through the fiber. The
attenuation varies with the wavelength. Refer to the specifications of the fiber
cable you are using, to obtain the fiber attenuation value. Typical values are 0.2
to 0.35 dBm/km.

Example 4: Calculate the maximum link distance for Link A from Example 2.
Using a worst case value of 0.35 for the fiber attenuation, the distance is:

18 dBm - 2 dBm

Distance =

_____________________________ 

  =  46 km

       0.35 dBm/km

Example 5: Calculate the maximum link distance for Link B from Example 3.
Using a worst case value of 0.35 for the fiber attenuation, the distance is:

22 dBm - 2 dBm

Distance =

_____________________________ 

  =  57 km

       0.35 dBm/km

Содержание Radiance CWDM System

Страница 1: ...Installation User Guide RADIANCE CWDM SYSTEM...

Страница 2: ...module w expansion 1550 1570 1590 1610 nm extended temperature range R416 A4 BE ___ 4 channel CWDM mux demux module w expansion 1470 1490 1510 1530 nm extended temperature range R416 A4 CE ___ 4 chan...

Страница 3: ...3 ____ 1 channel OADM drop insert module 1530 nm R436 J4 55 ____ 1 channel OADM drop insert module 1550 nm R436 J4 57 ____ 1 channel OADM drop insert module 1570 nm R436 J4 59 ____ 1 channel OADM drop...

Страница 4: ...Drop Insert Module 11 Installation Guide 12 Unpack the System 12 Mount the Chassis 13 Attach the Grounding Lug 14 Connect to the Network 14 User Guide 17 Calculating the Transmission Power Budget 17 C...

Страница 5: ...tomer premise The CWDM mux demux takes 4 or 8 different wavelength channels and combines multiplexes them onto one common fiber cable for transmission to the network It also separates demultiplexes th...

Страница 6: ...t channels each carrying 1 Gbps of bandwidth Expansion port on all 4 channel mux demux modules Color coded port labels for easy identification SC connectors Transparency to data frame sizes accommodat...

Страница 7: ...nodes on the network RX NETWORK NETWORK WEST RX EAST 1550 TX TX O A D M D R O P P A S S DROP Network West Port Drop Port Network East Port Wavelength of Drop Port The drop insert module terminates on...

Страница 8: ...X Single Fiber Pair Expansion Port The four channel mux demux can be configured to support additional channels through the expansion port By cascading the modules in series you can increase the total...

Страница 9: ...Demux 2 T X R X Exp Mux Demux 1 T X R X Channels 1 8 Channels 1 12 Local Interfaces Local Interfaces The Radiance CWDM System supports four 4 channel mux demux modules and one 8 channel mux demux The...

Страница 10: ...dule for transmission in the west bound direction thus completing the point to point connection between the local interface and another device located in the west That other device may be a mux demux...

Страница 11: ...op insert module receives the same channel from Local Interface A and inserts it onto the westbound fiber The same happens on the east side except in the opposite direction The drop insert module remo...

Страница 12: ...ts 8 screws CD ROM The following items are available separately NetBeacon software CWDM mux demux module OADM drop pass module OADM drop insert module 21 inch rackmounting hardware Your order has been...

Страница 13: ...he mounting brackets to the side panel You will need four 4 additional screws not included with the R4000 to mount the chassis into the rack Make sure that the mounting of the R4000 does not create a...

Страница 14: ...emode cables from your system equipment to the appropriate SC connectors on the CWDM mux demux module or OADM module The modules color codes are described below r o l o C h t g n e l e v a W r o l o C...

Страница 15: ...n the four channel mux demuxes this port is used to increase the number of available channels carried on the network cable TX RX NETWORK NETWORK NETWORK wwww xxxx zzzz EXPANSION yyyy TX RX WEST RX TX...

Страница 16: ...the four channel mux demux modules can be configured to support up to 16 different channels over the network An example of how to configure two modules is shown below NETWORK 1310 1330 1370 EXPANSION...

Страница 17: ...annel is dropped added or passed results in a loss of signal strength When calculating the power budget for a CWDM link all losses must be added together and then subtracted from Equation 1 above Powe...

Страница 18: ...9 0 dBm 18 dBm Example 3 Calculate the power budget for Link B in the following diagram Link B is the distance from CWDM SFP 1 to CWDM SFP 2 Radiance R5000 with R153 Line Cards Mux Demux 1 Mux Demux...

Страница 19: ...c Fiber attenuation is the loss of signal strength as it travels through the fiber The attenuation varies with the wavelength Refer to the specifications of the fiber cable you are using to obtain the...

Страница 20: ...irst module or an indication that the first slot is empty Name for the first module Part number for the second module or an indication that the second slot is empty Name for the second module As a Net...

Страница 21: ...ffice Mux Demux Drop Pass Switch Drop Pass MULTIPOINT TOPOLOGY Drop Insert Radiance R4000 with Drop Insert Module RING TOPLOGY Radiance R1000 with R153 Line Cards Drop Insert Radiance R1000 with R153...

Страница 22: ...Cards 8 Channel CWDM Mux Demux Modules 8 Channel CWDM Mux Demux Modules Radiance R5000 with R153 Line Cards POINT TO POINT TOPOLOGY RING TOPLOGY Radiance R4000 with two 4 Channel Mux Demux Modules Ra...

Страница 23: ...l CWDM Mux Demux Modules Radiance R4000 with Drop Insert Module REDUNDANCY AND PROTECTION TOPLOGY Radiance R1000 with R153 Line Cards Drop Insert Radiance R1000 with R153 Line Cards Drop Insert Router...

Страница 24: ...RX NETWORK NETWORK WEST RX EAST 1550 TX TX Thumb Screws Turn thumb screw clockwise to tighten Turn thumb screw counterclockwise to loosen O A D M D R O P P A S S DROP 3 Gently pull to remove the modul...

Страница 25: ..._________________________ SC Cable Type ____________________________________ 9 125 m singlemode Insertion Loss _____________________________________ 1 0 dBm OADM _________________________ 2 0 dBm 4 ch...

Страница 26: ...0 3 3 1 9 4 0 8 1 1 4 O m n 0 9 4 1 5 3 0 8 1 1 4 O m n 0 5 3 1 1 5 0 8 1 1 4 O m n 0 1 5 1 7 3 0 8 1 1 4 O m n 0 7 3 1 3 5 0 8 1 1 4 O m n 0 3 5 1 9 3 0 8 1 1 4 O m n 0 9 3 1 5 5 0 8 1 1 4 O m n 0 5...

Страница 27: ...bps Megabits per second Mux Multiplexer nm Nanometer OADM Optical Add Drop Multiplexing RX Receive SFP Small Form Factor Pluggable optical transceiver SNMP Simple Network Management Protocol TX Transm...

Страница 28: ...ase To return a defective product for warranty coverage contact Metrobility Customer Service for a return materials authorization RMA number Send the defective product postage and insurance prepaid to...

Страница 29: ...Radiance CWDM System 29 Notes...

Страница 30: ...e at http www metrobility com support manuals htm Product Registration To register your product go to http www metrobility com support registration asp 25 Manchester Street Merrimack NH 03054 USA tel...

Отзывы: