This low-emission, slow combustion appliance is designed 
to give you many years of warmth and service, subject to the 
following key factors. These key factors, if not adhered to are 
the major causes of unsafe installation, poor performance and 
flue blockages and product failure. 

1.   your Metro wood fire must be installed correctly. Metro 

recommend a competent and suitably qualified installer.

2.   The only fuel to be used in this appliance shall be wood 

that meets the following criteria.

 

– Less than 25% moisture,

 

– Has not been treated with preservatives or impregnated 
  with chemicals or glue,

 

– Is not chipboard, particle board, or laminated board, and

 

– Is not painted, stained or oiled

3.   The appliance shall be operated at all times in accordance 

with the “Installation and Operating Instructions” supplied 
with each appliance.

4.   Metro’s should only be installed with Metro ECO Flue 

Systems.

5.   Coal must not be used as a fuel.

Please also note the following important points:
•  In New Zealand a building consent is required from your 

local building authority. The homeowner is responsible for 
obtaining this consent.

•  As correct installation is critical to the performance 

and safe operation of your Metro, it is recommended 
your Metro be installed by a registered installer or a 
person suitably qualified in the installation of wood fires. 
your Metro retailer will be able to arrange professional 
installation for you.

•  During the very first fire your Metro will give off an odour 

and fumes as the firebox paint cures. Do not be alarmed; 
open all windows and externally opening doors in that 
room and close any internally opening doors. This curing 
process will last for approximately one hour and is likely to 
happen this one time.

•  Properly seasoned (dry) timber is necessary for the 

Metro to operate efficiently; firewood that contains a high 
moisture content will result in flue pipe blockages and 
reduce the heat output.

Note: Softwood usually takes 12 months to season - Hardwood can take 
up to 24 months to season - Wood must be stored in a location that 
enables air circulation. Unseasoned wood stored in a closed woodshed 
without air circulation will still be unseasoned 12 months later.

•     It is critical that the fire not be operated with over worn, 

faulty or missing door seals. Door seals will harden over 
time and become over-worn (3-4 year’s) this will cause air 
to leak into the fire, causing the appliance to ‘over fire’.

•  It is critical that the fire not be operated with over worn, 

faulty or missing bricks, baffle plate, baffle extension 
(white board on the baffle plate)

•  It is critical that the fire not be operated with cracked, or 

broken door glass.

Please note, the above 3 points require regular inspection/
maintenance (every time the ash bed is cleaned out, generally 
3-5 times a season) and if not maintained will void the firebox 
warranty. Please ensure you keep your proof of purchase/
receipt on any parts you buy.
•  For optimum performance fuel must be loaded so the logs 

lay “front to rear” in preference to laying across the width 
of the firebox. Spaces should be left between the logs to 
enable oxygen to get to as much of the surface of the fuel 
as possible.

•  A small hot fire loaded frequently is more efficient than a 

large fire burning on a low setting.

•  A key feature of all LTD Metro’s is their ability to burn at a 

very low rate. To familiarise yourself with correct operation 
of this feature, please ensure you read the “extended 
burning” section on page 10 of this manual so as not to 
void the Metro warranty by incorrect operation.

•  your Metro is covered by a full unconditional 12 month 

warranty on replacement parts, and a 10 year firebox 
warranty. See page 14 for warranty conditions.

Congratulations on the purchase of your Metro wood fire

•   WE HIGHLY RECOMMEND YOU READ THIS ENTIRE 

MANUAL AS INCORRECT OPERATION AND/OR LACK 

OF MAINTENANCE WILL VOID THE WARRANTY

•   Any modification of the appliance that has not 

been approved in writing by the testing authority is 

considered as breaching AS/NZS 4013

•   Do not use flammable liquids or aerosols in the 

vicinity of this appliance when it is operating

•  Never operate your Metro with the top grill removed

•   Do not use flammable liquids or aerosols to start or 

rekindle the fire

•   Never operate your Metro with the door ajar, 

except on initial start up

•   Do not store fuel within the Metro’s specified 

installation clearances

•   Do not dry clothes on or near this appliance
•   Open the air control before opening the Metro’s door

 WaRNINg! 

Important Information

•  This appliance should be maintained & operated at 

all times in accordance with this instruction manual

•   This appliance should not be operated with cracked 

door glass, over worn, faulty or missing door seals

•   Do not use driftwood, treated or unseasoned (wet) 

fuel, the use of most types of preservative treated 

wood as fuel can be hazardous

•   Do not empty ash into a combustible container

 CaUTION! 

Important Information

Содержание LTD Euro Ped

Страница 1: ...etrofires co nz www metrofires co nz Installation Important information 2 Assembling your Metro 2 3 Floor Protector Installation 4 Clearances and Specifications 5 Wetback and flue installation 6 7 Ope...

Страница 2: ...been developed to enhance the performance of Metro wood fires Any alternative flue system must have a minimum flue pipe length of 4 2 metres of 150mm diameter flue pipe The 150mm active flue pipe mus...

Страница 3: ...lts as shown in Diagram 1 with the open edge facing the front of the Metro up Position the pedestal with its front facing up over the four bolts and fit the nuts and washers supplied Check to ensure t...

Страница 4: ...loor protector is established and if the installation is in New Zealand seismic restraint is required Using masonry anchors if the floor protector is on a concrete floor or coach bolts if a wooden flo...

Страница 5: ...tional flueshield side extensions When fitted into an alcove situation not projecting forward of the Metro with flueshield side extensions fitted clearances B and G reduce by 80mm for the Wee Ped Clea...

Страница 6: ...rough the knockout holes 3 Open the Metro s door and locate two bolts securing the pressed washers which are visible on the left hand side of the firebox for both inlet and outlet connection points 4...

Страница 7: ...All Metro s require a 150mm diameter flue Please note All joints in the flue pipe must be sealed with Pioneer fire cement or similar and riveted The base of the flue pipe must be sealed into the outl...

Страница 8: ...r to leak into the fire causing the appliance to over fire It is critical that the fire not be operated with over worn faulty or missing bricks baffle plate baffle extension white board on the baffle...

Страница 9: ...tems are not suitable for use in locations where the water supply has lime content Lime build up inside the coil will eventually block the coil causing the wetback to fail Cost Savings Wetbacks can en...

Страница 10: ...ase of the firebox Add dry kindling and move the air control knob fully to the right being the full open position Light the paper at two or three locations across the front of the door opening and lea...

Страница 11: ...of the Metro s firebox and require removal The time this build up takes depends on the density and cleanliness of your fuel To remove the excess ash your Metro should not be operating Open the door an...

Страница 12: ...trial and error things to try H Cowl designed purely for downdraft issues but if you have an ECO Cowl fitted as standard you will also need to add another 600mm of flue pipe to compensate as the H Co...

Страница 13: ...urn chamber failing Failure of flue pipe or firebox due to creosote build up is not covered under warranty as creosote build up is only possible from either unseasoned fuel or incorrect operation The...

Страница 14: ...een neglected by not being regularly maintained and serviced warranty may be declined It is critical that the fire not be operated with over worn faulty or missing door seals Door seals will harden ov...

Страница 15: ...od fire keeping it in good order for many years to come Pioneer heating accessories ECO Flue Systems Pioneer Flashrites Pioneer Versatiles Lead Aluminium Silicone Pioneer Fire Cement Pioneer Fireguard...

Страница 16: ...page 16...

Отзывы: