Metro Fires LTD Euro Ped Скачать руководство пользователя страница 15

PAGE 15

All the accessories you’ll ever need!

Pioneer Manufacturing Limited distribute a wide range of 
heating accessories, and shown below are some of the heating 
accessories readily available from your local Metro retailer.

Some of these heating accessories are designed to compliment 
your Metro wood fire, and some are to assist with the up-keep 
and maintenance of your Metro wood fire, keeping it in good 
order for many years to come.

Pioneer heating accessories

ECO Flue Systems

Pioneer Flashrites

Pioneer Versatiles 

(Lead & Aluminium)

Silicone

Pioneer Fire Cement

Pioneer Fireguards

Pine Wall Floor Protectors

Rimu Wall Floor Protectors

Glass Tape 

- available in 1.6m lengths

Door Rope 

- available in 1.6m lengths

Alloy Corner Floor Protectors

Pine Corner Floor Protectors

Rimu Corner Floor Protectors

Alloy Wall Floor Protectors

Pioneer Heat Transfer Ducts

Fireside Toolset

Chubb Smoke Detectors

Pioneer High Temperature Paint

Wetbacks

Universal Door Seal Kits

Содержание LTD Euro Ped

Страница 1: ...etrofires co nz www metrofires co nz Installation Important information 2 Assembling your Metro 2 3 Floor Protector Installation 4 Clearances and Specifications 5 Wetback and flue installation 6 7 Ope...

Страница 2: ...been developed to enhance the performance of Metro wood fires Any alternative flue system must have a minimum flue pipe length of 4 2 metres of 150mm diameter flue pipe The 150mm active flue pipe mus...

Страница 3: ...lts as shown in Diagram 1 with the open edge facing the front of the Metro up Position the pedestal with its front facing up over the four bolts and fit the nuts and washers supplied Check to ensure t...

Страница 4: ...loor protector is established and if the installation is in New Zealand seismic restraint is required Using masonry anchors if the floor protector is on a concrete floor or coach bolts if a wooden flo...

Страница 5: ...tional flueshield side extensions When fitted into an alcove situation not projecting forward of the Metro with flueshield side extensions fitted clearances B and G reduce by 80mm for the Wee Ped Clea...

Страница 6: ...rough the knockout holes 3 Open the Metro s door and locate two bolts securing the pressed washers which are visible on the left hand side of the firebox for both inlet and outlet connection points 4...

Страница 7: ...All Metro s require a 150mm diameter flue Please note All joints in the flue pipe must be sealed with Pioneer fire cement or similar and riveted The base of the flue pipe must be sealed into the outl...

Страница 8: ...r to leak into the fire causing the appliance to over fire It is critical that the fire not be operated with over worn faulty or missing bricks baffle plate baffle extension white board on the baffle...

Страница 9: ...tems are not suitable for use in locations where the water supply has lime content Lime build up inside the coil will eventually block the coil causing the wetback to fail Cost Savings Wetbacks can en...

Страница 10: ...ase of the firebox Add dry kindling and move the air control knob fully to the right being the full open position Light the paper at two or three locations across the front of the door opening and lea...

Страница 11: ...of the Metro s firebox and require removal The time this build up takes depends on the density and cleanliness of your fuel To remove the excess ash your Metro should not be operating Open the door an...

Страница 12: ...trial and error things to try H Cowl designed purely for downdraft issues but if you have an ECO Cowl fitted as standard you will also need to add another 600mm of flue pipe to compensate as the H Co...

Страница 13: ...urn chamber failing Failure of flue pipe or firebox due to creosote build up is not covered under warranty as creosote build up is only possible from either unseasoned fuel or incorrect operation The...

Страница 14: ...een neglected by not being regularly maintained and serviced warranty may be declined It is critical that the fire not be operated with over worn faulty or missing door seals Door seals will harden ov...

Страница 15: ...od fire keeping it in good order for many years to come Pioneer heating accessories ECO Flue Systems Pioneer Flashrites Pioneer Versatiles Lead Aluminium Silicone Pioneer Fire Cement Pioneer Fireguard...