Measurements shown are in mm.

Model

WIDTH

DEPTH

HEIGHT

N

O

LTD Wee Rad

615

498

688

295

485

LTD Wee Ped

590

530

665

295

485

LTD Xtreme Rad

740

554

743

350

540

LTD Xtreme Ped

670

575

715

340

530

LTD Euro Ped

670

575

715

340

530

LTD Mega Rad

750

675

745

353

543

LTD Mega Ped

670

675

715

340

530

Measurements listed below are the minimum required, stated 
in millimetres. Measurements are taken from the following 
reference points as illustrated:

 -    From the nearest combustible wall or surface 

(A, B, D, E, G, H)

 -    From the Metro’s flue centre (A, B, C, D)

 -    From the outermost point of the Metro’s cabinet 

construction (E, F, G, H)

 -    To the edge of the ash floor protectors non-combustible 

surface (C, F, I, J, k, L, M)

The Metro Wee Ped has also been tested with optional 
“flueshield side extensions”. When fitted into an alcove 
situation not projecting forward of the Metro with flueshield 
side extensions fitted, clearances “B” and “G” reduce by 
80mm for the Wee Ped.

Clearance chart

Metro installation clearances

Minimum clearances shown are in mm, with a Pioneer double flue mounted shield fitted.

Model

A

B

C

D

E

F

G

H

I

J

K

L

M

LTD Wee Rad

243

548

580

425

120

230

240

100

823

825

1180

985

425

LTD Wee Ped

250

595

580

400

85

200

300

100

830

825

1145

950

425

LTD Xtreme Rad

251

650

630

458

100

227

280

100

881

907

1277

1081

507

LTD Xtreme Ped

250

575

625

455

110

200

240

100

875

905

1265

1065

505

LTD Euro Ped

250

575

625

455

110

200

240

100

875

905

1265

1065

505

LTD Mega Rad

270

675

725

500

125

200

300

120

995

905

1425

1175

505

LTD Mega Ped

270

610

725

465

130

200

275

120

995

905

1400

1140

505

Metro specifications

Note: Both wetback connections 
are 140mm left of the flue centre, 
facing the Metro/wall.

Содержание LTD Euro Ped

Страница 1: ...etrofires co nz www metrofires co nz Installation Important information 2 Assembling your Metro 2 3 Floor Protector Installation 4 Clearances and Specifications 5 Wetback and flue installation 6 7 Ope...

Страница 2: ...been developed to enhance the performance of Metro wood fires Any alternative flue system must have a minimum flue pipe length of 4 2 metres of 150mm diameter flue pipe The 150mm active flue pipe mus...

Страница 3: ...lts as shown in Diagram 1 with the open edge facing the front of the Metro up Position the pedestal with its front facing up over the four bolts and fit the nuts and washers supplied Check to ensure t...

Страница 4: ...loor protector is established and if the installation is in New Zealand seismic restraint is required Using masonry anchors if the floor protector is on a concrete floor or coach bolts if a wooden flo...

Страница 5: ...tional flueshield side extensions When fitted into an alcove situation not projecting forward of the Metro with flueshield side extensions fitted clearances B and G reduce by 80mm for the Wee Ped Clea...

Страница 6: ...rough the knockout holes 3 Open the Metro s door and locate two bolts securing the pressed washers which are visible on the left hand side of the firebox for both inlet and outlet connection points 4...

Страница 7: ...All Metro s require a 150mm diameter flue Please note All joints in the flue pipe must be sealed with Pioneer fire cement or similar and riveted The base of the flue pipe must be sealed into the outl...

Страница 8: ...r to leak into the fire causing the appliance to over fire It is critical that the fire not be operated with over worn faulty or missing bricks baffle plate baffle extension white board on the baffle...

Страница 9: ...tems are not suitable for use in locations where the water supply has lime content Lime build up inside the coil will eventually block the coil causing the wetback to fail Cost Savings Wetbacks can en...

Страница 10: ...ase of the firebox Add dry kindling and move the air control knob fully to the right being the full open position Light the paper at two or three locations across the front of the door opening and lea...

Страница 11: ...of the Metro s firebox and require removal The time this build up takes depends on the density and cleanliness of your fuel To remove the excess ash your Metro should not be operating Open the door an...

Страница 12: ...trial and error things to try H Cowl designed purely for downdraft issues but if you have an ECO Cowl fitted as standard you will also need to add another 600mm of flue pipe to compensate as the H Co...

Страница 13: ...urn chamber failing Failure of flue pipe or firebox due to creosote build up is not covered under warranty as creosote build up is only possible from either unseasoned fuel or incorrect operation The...

Страница 14: ...een neglected by not being regularly maintained and serviced warranty may be declined It is critical that the fire not be operated with over worn faulty or missing door seals Door seals will harden ov...

Страница 15: ...od fire keeping it in good order for many years to come Pioneer heating accessories ECO Flue Systems Pioneer Flashrites Pioneer Versatiles Lead Aluminium Silicone Pioneer Fire Cement Pioneer Fireguard...

Страница 16: ...page 16...

Отзывы: