5. GENERAL SPECIFICATIONS
Safety
Compliance with the safety norm:
IEC 1010-1 (NF EN 61010-1 +A2 : 1995)
Insulation class 1
Pollution level: 2
•
Power supply outputs: Overvoltage category 100 V CAT I in relation to the earth
Maximum output voltage: 30.5 V
DC
in normal mode
61.0 V
DC
in series mode
•
Mains power supply: Overvoltage category 300 V CAT II
Supply current: 115 V or 230 V ± 10 %; 50-60 Hz
Guaranteed insulation of the outputs from the mains when used at extra low
safety voltage.
AX 501
AX 502
AX 503
Weight
4 kg
4.5 kg
6 kg
Dimensions
270 mm x 225 mm x 120 mm
Packaging
400 mm x 345 mm x 250 mm
Power supply
For the voltage value, refer to the label on the rear of the power supply.
Two mains ranges:
115 V
AC
± 10 % or 230 V
AC
± 10 %.
Display
2 displays (3 digits) "VOLTAGE" in green and "CURRENT" in red
7 segments
Digit size: 14.2 mm
Environmental
Use
10°C to 40°C
conditions
Operating not specified for :
0°C to 10°C and 40°C to 50°C
over 40°C :
limit the operating duration to 1 hour
Storage
-20°C to +70°C
Coefficient
< 0.1 x accuracy / °C
Relative humidity
< 80 % RH up to 40°C
Electrical field
nil
Magnetic field
< 40 A / m
Altitude
< 2000 m
EMC
•
Conducted radiation emissions:
NF EN 50081-1: 1992
•
Immunity:
NF EN 50082-1: 1998
6. ACCESSORIES
6.1.
Accessories delivered with the power supply
1 user's manual (5 languages)
906129643
6.2.
Optional accessories
20 A / 25 cm safety leads, male / male, red
AG1001 (
∗
)
20 A / 25 cm safety leads, male / male, black
AG1002 (
∗
)
20 A / 50 cm safety leads, male / male, red
AG1008 (
∗
)
20 A / 50 cm safety leads, male / male, black
AG1009 (
∗
)
Green/yellow earth safety lead, female, 2 m
AG1041 (
∗∗
)
(*) pack of 10
(**) pack of 5
Mechanical
features