background image

 

Technical characteristics of the MTX 3291 

60 

6,000- and 60,000-count digital multimeters 

Technical characteristics of the MTX 3291 (continued) 

Variation in the 
nominal range of use 

 

Quantity of 

influence 

Range of 
influence 

Quantity influenced

Influence  

typical 

MAX 

Batt. voltage 

4V to 6V 

all 

<

3D 

0.2% L+1D 

Temperature 

-10°C… 18 

28 ... 55°C 

V

DCmV

 

0.02% L ±0.2D/1°C 

0.04% L ±0.25D/1°C 

V

ACmV

, V

LowZ

mV 

0.08% L ±0.2D/1°C 

0.15% L ±0.25D/1°C 

V

DC

 

0.01% L ±0.1D/1°C 

0.05% L ±0.1D/1°C 

V

AC

, V

AC+DC

,V

LowZ

 

0.25% L ±0.1D/1°C 

A

DC

 

0.05% L ±0.1D/1°C 

0.1% L ±0.1D/1°C 

A

AC

 and A

AC+DC

 

0.08% L ±0.1D/1°C 

0.12% L ±0.1D/1°C 

 

0.01% L ±0.1D/1°C 

0.1% L/1°C 

Ω

 

0.05% L/1°C 

0.1% L/1°C 

60 M

Ω

 

 

0.3% L/1°C 

µF 

 

0.2% L ±0.1D/1°C 

mF 

 

0.6% L ±0.1D/1°C 

Hz 

 

0.01% L/1°C 

Temp. 

 

±

 2°C+0.05% L/1°C 

Stabilization time 

 2h  

2.5h 

Humidity 

(without 

condensation) 

10%... 80% RH


 

Ω

 (*) 

Hz 

EMC  

(immunity to the 

radiated field) 

300MHz...  

500MHz 

 

clamp 

 

600 pts 

300MHz...  

500MHz 

450 pts 

Common mode 

1000V  

50Hz 

V

AC

, V

AC+DC

,V

LowZ

 

Range 

typical 

 

60mV 

600mV 

>35dB 

6V 

>60dB 

60V  

600V  

1000V 

>95dB 

Response of the  
300Hz filter 

-60,00

-50,00

-40,00

-30,00

-20,00

-10,00

0,00

0

50

100

150

200

250

300

350

400

450

Fr

e

quenc

y

 (Hz)

Er

re

u

r (

%

)

Erreur (%)

 

Содержание ASYC-IV MTX 3290

Страница 1: ...lay ASYC IV MTX 3290 6000 cts MTX 3291 60000 cts Operating instructions P le Test et Mesure CHAUVIN ARNOUX Parc des Glaisins 6 avenue du Pr de Challes F 74940 ANNECY LE VIEUX Tel 33 0 4 5064 2222 Fax...

Страница 2: ...8 Functional description 19 1 MAX MIN AVG mode 19 2 PEAK mode 22 3 REL mode 23 4 CLAMP function 25 Functions of the switch and keys 26 How are the various quantities measured 28 1 Voltage measurement...

Страница 3: ...d safety measures This instrument is been designed to be used as follows indoors in an environment of pollution degree 2 at an altitude of less than 2000m at a temperature between 10 C and 55 C at a r...

Страница 4: ...Automatic detection The number of input terminals is limited to 3 V COM A Connecting the lead to the Ampere terminal automatically selects the corresponding function When a change of function by the...

Страница 5: ...lead or an accessory belonging to a lower measurement or voltage category derates the resulting system instrument leads accessories to the lowest measurement category and or service voltage of any of...

Страница 6: ...ne power and from the measurement circuits and make sure that you are not charged with static electricity which might destroy internal components An adjustment maintenance or repair of the live instru...

Страница 7: ...re strictly forbidden y Checking the current fuse Fuse SIBA 5019906 MTX 3291 11A 10x38 1 000V F breaking capacity 20kA MTX 3290 10A 6x32 600V F breaking capacity 50kA Rechargeable and primary batterie...

Страница 8: ...Description of the instruments 8 6 000 and 60 000 count digital multimeters Description of the instruments MTX 3290 Frontal panel Back Prop Terminal block Optical connector not active...

Страница 9: ...Description of the instruments 6 000 and 60 000 count digital multimeters 9 Description of the instruments continued MTX 3291 Frontal panel Back Prop Terminal block Optical connector active...

Страница 10: ...tities measured VLowZ AC voltage measurement at low impedance VLowZ VAC AC voltage measurement VAC DC DC or AC DC voltage measurement at high impedance V A Current measurement A Hz Frequency measureme...

Страница 11: ...ment impossible O L Overshoot of the measurement capacities USER USER mode on main display unit BASIC BASIC mode on main display unit Z Hertz symbol main display unit Z Hertz symbol secondary display...

Страница 12: ...ut COM measurement input Ampere measurement input 600V CAT III Input indication 1000V CAT III Input indication Isolated optical link USB input Display of unit on the main display unit 2x14 segments Di...

Страница 13: ...o another resets the configuration of the measurement mode MTX 3290 Keys of the switch Short press Successive short presses Current measurement Temperature measurement Selection of the type of probe P...

Страница 14: ...t1000 Capacitance measurement Low impedance AC voltage measurement VLowZ Current measurement using a current clamp Selection of the transformation ratios 1 10 100 1 000mV A Resistance measurement audi...

Страница 15: ...n the MAX MIN AVG PEAK mode when the HOLD is active the blinking of the MAX MIN AVG PEAK symbol indicates that acquisition continues as a background task Hold of the display after stabilization of the...

Страница 16: ...difference between the measured value and the reference value in the unit of the quantity measured AVG displays the mean value of the signal since the key press Time stamped value for the min and the...

Страница 17: ...ents of the display unit 2nd press display of model and version US Europe 3rd press software version display unit 1 and keyboard and display unit board versions display unit 2 4th press normal operati...

Страница 18: ...Reminder after replacing the batteries wait 10s before powering the device back up If the multimeter malfunctions a long press 2s on this key can be applied to power down the instrument and then rest...

Страница 19: ...isplay unit Secondary display unit Measured signal 230V 50Hz Present value of the signal Frequency of the signal for the MAX value 1st press on Present value of the signal MAX value The measured signa...

Страница 20: ...tinued The display then becomes Present value of the signal MAX value for the MIN value 2nd press Ex 3s Momentary screen 4s indicating the time stamped max value if the value changes or if the value i...

Страница 21: ...onal description 6 000 and 60 000 count digital multimeters 21 Functional description continued for the AVG value 3rd press on Present value of the signal AVG value De activation By a long press on th...

Страница 22: ...ates an overshoot or a change of quantity Displays in the VAC DC function Measured signal 250V 50Hz Present value of the signal MIN value for the Peak value First press on Present value of the signal...

Страница 23: ...Displays in the VAC DC function Measured signal 1V 100Hz Present value of the signal Frequency of the signal Activation of the REL mode by Short press on the key REL present value reference value Refe...

Страница 24: ...digital multimeters Functional description continued Short press in the REL mode on Present value reference value Reference value Reference value A long press on the key erases the reference value De...

Страница 25: ...00 count digital multimeters 25 Functional description continued 4 Clamp function Ex 10mV A Present value of the signal Transformation ratio selected by successive presses on press 1 1mV A press 2 10m...

Страница 26: ...VLowZ VLowZ VlowZ 3 R 1 R 10 R 100 R 1000 R 1 3 Continuity Diode Continuity 3 Frequency Frequency Frequency Frequency Frequency 3 MTX 3291 Press 1 Press 2 Press 3 Press 4 Press 5 Press 6 Short press...

Страница 27: ...ations according to the type of measurement Type of measurement MAX MIN AVG PEAK REL RANGE HOLD Auto Manu Voltage VLowZ Voltage VAC Voltage VAC DC Current AAC AAC DC 9 9 9 in REL only 9 9 9 9 Voltage...

Страница 28: ...hen the measurement exceeds 1000V MTX 3291 or 600V MTX 3290 1 Press or 2 Select AC DC AC or DC coupling of the signal by pressing the default coupling is AC DC Depending on what you select the screen...

Страница 29: ...not correct an audible beep and a visible signal LEADS are activated 4 Place the test probes in series between the source and the load 5 Read the measurement value indicated on the display unit O L is...

Страница 30: ...0mV A 100mV A or 1000mV A by pressing on clamp to have a direct reading of the current 5 Place the clamp around the conductor 7 Read the measurement value indicated on the display unit The measurement...

Страница 31: ...ss several times to obtain MTX 3291 only positive duty cycle DC negative duty cycle DC positive pulse duration Pw negative pulse duration Pw It is possible to activate the filter in AAC DC AAC The cut...

Страница 32: ...s for a resistance measurement 5 Read the measurement value indicated on the display unit 6 The continuity beep sounds when R 30 5 7 O L is displayed if the circuit is open 6 Diode test 1 Press 2 Pres...

Страница 33: ...ent value indicated on the display unit O L is displayed if the value to be measured exceeds the capacitance of the range O L is displayed if the capacitor is short circuited For high values the measu...

Страница 34: ...splayed as default on the main display unit is C 4 Connect the adapter of the Pt100 or Pt1000 temperature probe to the COM and V terminals making sure that the polarity is correct 5 Read the measureme...

Страница 35: ...t the black lead to the COM terminal and the red lead to V 5 Place the test probes between two phases of the circuit to be measured 6 Read the measurement values indicated on the display unit voltage...

Страница 36: ...red lead to A 5 Place the test probes in series between the source and the load 6 Read the measurement value indicated on the display unit O L is displayed if I 20A The presence of the symbol indicat...

Страница 37: ...displays DC AC or AC DC 4 Connect the black lead to the COM terminal and the red lead to V 5 Place the test probes on the terminals of the circuit to be measured to measure the resistance Press The d...

Страница 38: ...black lead to the COM terminal and the red lead to V 5 Place the test probes on the terminals of the circuit to be measured Connect the instrument as for a voltage measurement 6 Read the measurement v...

Страница 39: ...input of the multimeter on the side of the multimeter Mechanical polarization prevents connection in reverse Connect the USB lead to one of the USB ports of the PC 2 Install the USB driver on your PC...

Страница 40: ...L above 620V Protection 850Vpk Secondary measurements and displays MAX MIN AVG AC and AC DC voltages With this function the user can measure the true RMS TRMS value of an AC voltage with its DC compon...

Страница 41: ...or above 620VRMS 3 From 1kHz the measurement must exceed 15 of the range Secondary measurements and displays FREQ AC coupling MAX MIN AVG PEAK VLowZ AC Protection 850Vpk The pass band is reduced to 3...

Страница 42: ...D 0 58mV mA 6A 0 to 6 000A 0 200 to 6 000A 0 001A 1 2 L 3D 0 05V A 10 A 20A 0 to 20 00A 0 20 to 20 00A 0 01A 1 2 L 2D 0 05V A The display indicates OL above 19 99A The symbol blinks and a beep sounds...

Страница 43: ...15D 2 6 to 5mA 25mV mA Fuse 10A 600V 50kA 60mA 0 to 60 00mA 6 00 to 60 00mA 0 01mA 1 5 L 0 08 x FkHz 1 L 3D 13D 2 6 to 50mA 3mV mA 600mA 0 to 600 0mA 60 0 to 600 0mA 0 1mA 2 6 to 500mA 0 58mV mA 6A 0...

Страница 44: ...1kHz 60kHz 0 to 60 00kHz 0 01 to 60 00kHz 0 01kHz 600kHz 0 to 200 0kHz 0 1 to 200 00kHz 0 1kHz Below 10Hz or if the signal detection level is inadequate the reading is forced to zero The measured peri...

Страница 45: ...26 A 6M 0 to 6 000M 0 001M 1 5 L 3D 240nA 60M 0 to 60 00M 0 01M 3 L 3D 29nA REL measurements Capacitance Capacitance meter In this setting the user can measure the capacitance of a capacitor Range Op...

Страница 46: ...error of the multimeter specified in the tables below DC current Range Ratio 600mA 6A 60A 600A 6000A 1mV A Resolution 0 01A 0 1A 1A Accuracy 0 6 L 2D 0 6 L 2D 0 3 L 2D 10mV A Resolution 0 001A 0 01A...

Страница 47: ...001A 0 01A 0 1A Accuracy 2 8 L 15D 2 8 L 15D 2 8 L 13D 100mV A Resolution 0 1mA 0 001A 0 01A Accuracy 2 8 L 15D 2 8 L 15D 2 8 L 13D 1000mV A Resolution 0 1mA 0 001A Accuracy 2 8 L 15D 2 8 L 13D Peak f...

Страница 48: ...Add 1 L 30 D to obtain the accuracy corresponding to the function and the range Fmax 1kHz 1ms Protection 850Vpk 1ms mini SURV MIN MAX AVG Add 0 2 L 2D to obtain the accuracy corresponding to the func...

Страница 49: ...1 C VDC 0 01 L 0 1D 1 C 0 05 L 0 1D 1 C VAC VAC DC VLowZ 0 25 L 0 1D 1 C ADC 0 05 L 0 1D 1 C 0 1 L 0 1D 1 C AAC and AAC DC 0 08 L 0 1D 1 C 0 12 L 0 1D 1 C 0 01 L 0 1D 1 C 0 1 L 1 C 0 05 L 1 C 0 1 L 1...

Страница 50: ...D 10 008M 1 This range is accessible only with the Range key Input impedance approx 10 6M 50 pF 2 The display indicates OL above 1050V and OL below 1050V Secondary measurements and displays MAX MIN AV...

Страница 51: ...1000 0V 1 See the typical curve of the 300Hz 2 The LCD indicates OL above 1050V OL below 1050V or above 1050VRMS 3 From 1kHz the measurement must exceed 15 of the range Secondary measurements and dis...

Страница 52: ...ary to wait some time for the metrological characteristics specified in these ranges Range Operating range Specified measurement range Resolution Uncertainty Voltage drop Protection 600 A 0 to 600 00...

Страница 53: ...C max Additional uncertainty with the 300Hz filter AAC DCTRMS current Warning the sum AC DC must never exceed the range 600mA or 60mA or 6mA or 600 A or 6A or 10A as the case may be The AC component m...

Страница 54: ...z 0 01 to 60 00kHz 0 01kHz 600kHz 0 to 200 0kHz 0 1 to 200 0kHz 0 1kHz Below 10Hz or if the signal detection level is inadequate the reading is forced to zero The measured period in ms is available on...

Страница 55: ...00 00k 0 01k 1 26 A 6M 0 to 6 0000M 0 0001M 1 5 L 30D 240nA 60M 0 to 60 000M 0 001M 3 L 30D 29nA REL measurements Capacity Capacitance meter In this setting the user can measure the capacitance of a c...

Страница 56: ...lamps and obtain a direct reading of the current by selecting the correct transformation ratio which must be the same as that of the clamp If the signal detection level is insufficient the value is fo...

Страница 57: ...ents and displays MAX MIN AVG and transformation ratio of the sensor 300Hz filter if the filter is active see 300Hz filter curve for the additional uncertainty AAC DC TRMS current Range Ratio 600mA 6A...

Страница 58: ...approximately 100ms Protection 1414 Vpk Resistive power Display of the resistive power with respect to a reference resistance measured on the installation and saved in memory using the HOLD key 600 is...

Страница 59: ...tection 1414 Vpk dBm Display of the measurement in dBm with respect to a resistance reference chosen by the user from among 50 75 90 and 600 default value 600 Resolution 0 1dBm Absolute error in dBm 0...

Страница 60: ...1 C VAC VAC DC VLowZ 0 25 L 0 1D 1 C ADC 0 05 L 0 1D 1 C 0 1 L 0 1D 1 C AAC and AAC DC 0 08 L 0 1D 1 C 0 12 L 0 1D 1 C 0 01 L 0 1D 1 C 0 1 L 1 C 0 05 L 1 C 0 1 L 1 C 60 M 0 3 L 1 C F 0 2 L 0 1D 1 C m...

Страница 61: ...x1 5V nominal LR6 Alkaline Life in VDC MTX3290 200h MTX3291 300h Rechargeable batteries 4x1 2V A A Ni MH LSD 2400mAh Life in VDC MTX3290 140h MTX3291 210h Display The refresh rate of the display unit...

Страница 62: ...external charger HX0051B External charger for 4 Ni MH rechargeable batteries HX0053 HV probe SHT 40kV CMS clamp HX0064 Multifix adapter for DMM P01102100Z spare MTX 3291 Fuse 11A 10x38 1000V Fast bre...

Отзывы: