MD 9010 General Purpose Auto – Check Digitalmultimeter
Specification
12
AC
A Current
(MD 9010)
RANGE
Accuracy Burden
Voltage
50Hz -- 60Hz
400.0
A
2.0%+3d
6mV/
A
2000
A
1.5%+3d
6mV/
A
Audible Continuity Tester
Open Circuit Voltage: 0.4VDC typical
Audible Threshold:
MD 9010: between 50
and 300
Non-Contact EF-Detection
(MD 9010)
Threshold Voltage
Between
MD 9010
Bar Graph
20V & 80V
-
45V & 125V
- -
70V & 215V
- - -
120V & 285V
- - - -
170V & up
- - - - -
Indication: Bar graph segments & audible
beep tones proportional to the field
strength
Detection Frequency: 50/60Hz
Detection Antenna: Top left corner of the
meter
Probe-Contact EF-Detection: For more
precise indication of live wires, use the
Red (+) probe for direct contact
measurements