A 1632
eMobility Analyser
Adapter description
10
8
Type 2 INPUT socket for connection of a 3 phase Mode 3 charging cable
9
1 phase INPUT socket for connection of a 1 phase Mode 2 charging cable
22
3 phase INPUT socket for connection of a 3 phase Mode 2 charging cable
10
RS232 connection port (intended for firmware upgrade and service purposes)
11
ON multicolour LED
See chapter
for more information.
12
ON / OFF key
Switches the eMobility Analyser On (short press) or Off ( 2 s press).
Auto-off after 20 minutes of no-activity.
13
Remote LED indicates that the adapter is controlled by Metrel safety tester (inclusive
CP, PP and Error state)
14
Rotary switch for selection of different simulated errors:
See chapter
15
Error ON key
Switching On/Off the selected error.
16
Error ON LED
ON = Error applied, OFF = Error not applied
17
Rotary switch for setting Control Pilot state (CP on OUTPUT side)
Position
Description
D
EV charged and ventilation
B
EV connected
A
no EV connected
B
EV connected
C
EV charged
18
Rotary switch for setting Proximity Pilot current rating resistor (PP on OUTPUT side)
[NC, 13 A, 20 A, 32 A, 63 A, 80 A]
19
Lx/ N/ PE/ CP/ PP/ CP MON safety OUTPUT sockets for connection of a safety tester
20
L/L1, L2, L3 OUTPUT LED
’s
ON = mains voltage at the OUTPUT test connection present,
OFF = mains voltage at the OUTPUT test connection not present.
21
OUTPUT connectors for test cable connection to the output of charging cable or
EVSE
Note:
On INPUT side, the L/L1, L2, L3, N, PE, CP and PP safety sockets (4) are connected in parallel