A 1322 / A 1422
Measurements with A 1422
24
6.2 Insulation resistance (welding circuit to protective circuit)
Refer to master instrument Instruction manual, chapter
Single test
measurements
, subchapter
Insulation resistance Riso (Welding equipment)
for detailed information.
Procedure:
Item
Comment
Prepare test system.
See
chapter 4.3 Working
Connect power supply plug of tested welding
machine into proper test socket.
Connect welding terminals to W1 and W2 terminals
on A 1422.
Select Riso (Rw) test function on the master
instrument.
Set Test parameter to W-PE.
Start measurement.
Wait until measurement is finished or stop the
measurement.
Check result(s).
Store result(s).
Optional
Figure 6.2:
Insulation resistance (welding circuit to protective circuit) measurement
Notes:
Consider any warning on the display before starting the measurement!
Do not touch or disconnect the DUT during the insulation resistance
measurement or before it is fully discharged!