![Metra Electronics Metra Electronic Lock Скачать руководство пользователя страница 17](http://html1.mh-extra.com/html/metra-electronics/metra-electronic-lock/metra-electronic-lock_installation-manual_1778828017.webp)
15
NOTE:
If the lockers are precisely made and quality hinges are used, the strike position does not vary from one to another.
According to strike position in the first locker, all remaining can be positioned the same just on optical evaluation to speed-
up the assembly procedure. Final corrections can be done during functional test of the locker if needed.
•
Final Operational test of the locker.
Final check of the locker and mounting should be done after the lock is operational and connected to the control card or
test unit.
Place the Metra mounting jig on the loop and firmly close the
door to position the strike and then tighten the screws. Do not
over-tighten the screws, the wire loop should still move freely.
Remove the mounting jig.
CORRECTLY TIGHTEND SCREWS.
Try moving the wire loop left and right in the mount. If correctly
tightened, the wire loop should be able to move..
Содержание Metra Electronic Lock
Страница 12: ...10...
Страница 20: ...18 Electronic Lock Centralised Technical drawing Overhead view of Electronic Lock Body Strike...
Страница 21: ...19 Electronic Lock RFID DOT Technical drawing Dimensions...
Страница 22: ...20 Cable entry hole drilling guide for Electronic Lock...
Страница 23: ...21 Metra Control Cabinet Preferred back wall layout...