Metra Electronics ADS-200 Скачать руководство пользователя страница 9

9

9.1.  The Metra Separator switching on:

1.  Set the ‘Feed Gate Control’ handle to the ‘0’ position.
2.  Fill the hopper with grain to the specified level, not less than minimal level.
3.  Reset the ‘EMERGENCY STOP’ button.
4.  Move the ‘POWER’ knob to ‘ON’. The ‘POWER’ indicator will light up if it is under  voltage.
5.  Set the ‘POWER’ knob to the middle position.
6.  Turn on the frequency converter power, by setting the ‘DIRECTION OF ROTATION’ switcher in the separation or 

reverse mode.  Together with the indicator lights, the impeller motor will begin to smoothly gain speed reaching 
predetermined speed.

7.  Turn off the Metra Separator in reverse order.
8.  Pressing the ‘EMERGENCY STOP’ button carries out emergency shutdown of the Metra Separator.

Press the ‘EMERGENCY STOP’ button only in cases of emergency!

9.2.  Operating modes settings:

Preliminary cleaning mode

1.  Switch on the Metra Separator as described above.
2.  Fill the hopper with material. Ensure continuous supply of the material to the hopper. During operation the user must 

control the amount of the material in the hopper - it must be filled to at least 75% of its volume.

3.  Set the baffles in upward position, so they are in ‘0’ position.
4.  Turn the ‘Feed Gate Control’ handle to open position. Adjust the ‘Speed’ knob to the maximum possible value, so the 

grain (or other clean material) is not coming out with the light impurities removal.

5.  If the Metra Separator is equipped with CDC (Cyclone Dust Collector), make sure that all connections are tight with the 

main Metra Separator. Make sure that the gate duct is blocked. Restriction or partial overlapping of the CDC output 
tray is not allowed, as this may lead to malfunction of the Metra Separator.

In this mode, when the Metra Separator is properly adjusted, it’s able to remove 30% to 60% of the original waste material, 
depending on the quality of the grain. When the Metra Separator is operating in this mode, refined grain will be fed from 
all trays. 

Note that when the material is very dirty, you might need to clean in several stages: first to separate good grains from the 
2nd − 3rd trays, having dropped the rest of the material from the 4th − 6th trays into a common storing hopper, and then 
clean and grade the second time the grains from the 4th − 6th trays.

Precise grading mode

1.  Switch ON the Metra Separator as described above. 
2.  Fill the hopper with material. Ensure a continuous supply of the material to the hopper. During operation the user must 

control the amount of the material in the hopper - it must be filled to at least 75% of its volume.

3.  Set the baffles in upward position, so they are in ‘0’ position.
4.  Turn the ‘Feed Gate Control’ handle to a position of ‘0.5-1’. 

5.  Adjust the ‘Speed’ knob so to receive clean grain in the 2nd-4th trays/outputs.

9. ADJUSTMENT PROCEDURE

Содержание ADS-200

Страница 1: ...1 OPERATING MANUAL GRAIN CLEANER METRA ADS...

Страница 2: ...ations 4 2 Configuration 5 3 Distinctiv e Features 5 4 Operation 6 5 Labeling 6 6 Safety Regulations 7 7 Mounting 8 8 Adjustment Procedure 9 9 Capacity Calculation 11 10 Maintenance 12 11 Transportati...

Страница 3: ...or operating the Metra ADS grain cleaner This document contains information about the Metra ADS Grain cleaner its technical specification safety instructions information about the manufacturer and war...

Страница 4: ...ode Dimensions length width height Energy consumption Weight ADS 200 200 bushels in hour 5 tons in hour 84 6 22 68 9 in 2150 560 1750 mm 0 2 1 0 HP 0 2 0 75 kW 220 480 V 60 Hz 290 lbs 130 kg ADS 400 4...

Страница 5: ...Frequency Drive is incorporated for motor speed control This allows precise air flow adjustment so that the Metra Separator is accurately tuned for operation with any material The separation chamber...

Страница 6: ...venth output trays are collecting feed forage seeds The dust chaff and other light impurities are blown out with the airflow outside the Metra Separator or directed through the CDC Cyclone Dust Collec...

Страница 7: ...e wire and cable with hot wet oily surfaces or objects When working with treated seed it is necessary to conduct medical examinations and provide staff with personal protective equipment While operati...

Страница 8: ...ocess if necessary the conveyors will be completed as option 8 3 Connection to power supply The Metra Separator connection to power mains must be performed by a qualified electrician having electrical...

Страница 9: ...the grain or other clean material is not coming out with the light impurities removal 5 If the Metra Separator is equipped with CDC Cyclone Dust Collector make sure that all connections are tight wit...

Страница 10: ...ion chamber Please note The capacity of the Metra Separator can be increased the amount of grain fed into the separation chamber can be increased until the process of cleaning grading gets worse The e...

Страница 11: ...5 0 25 Peas 800 1 00 Hummel rice 700 0 50 Wheat 760 1 00 Awned rice 700 0 40 Corn 700 1 00 Sugar beet 300 0 40 Bread corn 700 0 9 Millet 850 0 30 Barley 650 0 8 Rapeseed 0 30 Vetch oatmeal mix 0 75 Li...

Страница 12: ...ng parts When withdrawing the Metra Separator from storage or preservation it is necessary to remove dust and dirt deposits using a soft cloth check the smoothness of the impeller rotation and carry o...

Страница 13: ...The Metra ADS Separator can be transported by any means of transport according to the shipping rules Placing and securing of cargo is carried out in accordance with the current technical rules of carg...

Страница 14: ...of the Metra Separator is carried out in a dry ventilated space Rainfall and foreign objects hit is not allowed STORAGE Date Storage conditions Storage type Remarks Accepted for storage Withdrawn fro...

Страница 15: ...15 REPAIR Date Operating time since the beginning of operation period hours Operating time after the last repair hours Reason for repair Information about repair...

Страница 16: ...16 MOVEMENT IN OPERATION Mounting date Mounting place Dismounting date Operating time from the beginning of operation period hours Reason for dismounting Full name and signature...

Страница 17: ...17 Metra Separator strapping scheme Annex 1...

Страница 18: ...18...

Отзывы: