![Metra Electronics ADS-200 Скачать руководство пользователя страница 11](http://html1.mh-extra.com/html/metra-electronics/ads-200/ads-200_operating-manual_1778820011.webp)
11
Formula for capacity calculation:
Q=QN*K1*K2
where: QN- nominal capacity, t/h;
Kl, K2 - conversion factor (Table 4 and Table 5).
Conversion factor of grain cleaning capacity depending on the crop
10. CAPACITY CALCULATION
Crop
Bulk weight,
kg / cubic
meters
Factor K1
Crop
Bulk weight,
kg / cubic
meters
Factor K1
Beans
-
1.20
Sunflower seeds
355
0.25
Peas
800
1.00
Hummel rice
700
0.50
Wheat
760
1.00
Awned rice
700
0.40
Corn
700
1.00
Sugar-beet
300
0.40
Bread-corn
700
0.9
Millet
850
0.30
Barley
650
0.8
Rapeseed
-
0.30
Vetch oatmeal mix
-
0.75
Linseed, camelina
700
0.25
Meadow grass
-
0.04
Wheat grass
-
0.25
Buckwheat
650
0.70
Cow clover
780
0.20
Spring vetch
-
0.70
Medick
780
0.20
Oatmeal
500
0.70
Ryegrass
-
0.15
Soybean
720
0.70
Meadow fescue
grass
-
0.14
Sorghum
750
0.60
Cat's-tail
700
0.12
Lentil
765
0.60
Carrot
480
0.10
Kenaph
-
0.60
Cocksfoot
-
0.09
Winter vetch
-
0.60
Table 4