6.2. Control labeling:

Controls of the Metra Separator operation, the buttons/switches are the following:
- ‘ON’ 
- ‘OFF’
- ‘START’ 
- ‘STOP’ 
- ‘ROTATION DIRECTION’
- ‘SPEED’
- ‘EMERGENCY STOP’.

Before operating the Metra Separator, the user must comply with the following safety requirements:

Check the reliability of the connection of visible ground (protective earth) conductors to the equipment, availability and 
reliability of grounding contacts fastening, plugs, sockets, and connectors;

Total resistance of earthing devices: all re-grounding neutral conductor transmission line shall not exceed 10 Ohms.

The construction of connector plugs must be so that they cannot be plugged in with a higher nominal voltage than the 
rated Metra Separator voltage. Prior to connecting, make sure that suitable voltage is applied according to the connector 
base diagram. Avoid pulling and twisting of cables or power cords when connecting the equipment. Do not subject them to 
mechanical stress & do not put loads on them. Avoid direct contact between the wire and cable with hot, wet, oily surfaces 
or objects.

When working with treated seed it is necessary to conduct medical examinations and provide staff with personal protective 
equipment.

While operating the Metra Separator without CDC (Cyclone Dust Collector) the user should wear dust-proof goggles and 
a respirator.

CAUTION!

Mounting (dismounting) of the Metra Separator is to be performed only when equipment is de-energized.

Mounting (dismounting) of the Metra Separator is to be performed only on a flat stable surface, while following all the 
mounting (dismounting) rules and requirements.

FORBIDDEN!

•  Do not operate the Metra Separator without reading the operating instructions.
•  Do not operate the Metra Separator without grounding.
•  Do not operate the Metra Separator when the power supply voltage is non-compliant with electrical installation 

code requirements, namely for voltage 220V + - 10%.

•  Do not operate the Metra Separator without any protective elements of the rotating parts.
•  Do not open units and blocks under voltage.
•  Do not make changes in the program of the frequency converter.
•  Do not operate the Metra Separator in places where precipitation may fall on it (rain, snow, fog, dew etc.).

7. SAFETY REGULATIONS

Содержание ADS-200

Страница 1: ...1 OPERATING MANUAL GRAIN CLEANER METRA ADS...

Страница 2: ...ations 4 2 Configuration 5 3 Distinctiv e Features 5 4 Operation 6 5 Labeling 6 6 Safety Regulations 7 7 Mounting 8 8 Adjustment Procedure 9 9 Capacity Calculation 11 10 Maintenance 12 11 Transportati...

Страница 3: ...or operating the Metra ADS grain cleaner This document contains information about the Metra ADS Grain cleaner its technical specification safety instructions information about the manufacturer and war...

Страница 4: ...ode Dimensions length width height Energy consumption Weight ADS 200 200 bushels in hour 5 tons in hour 84 6 22 68 9 in 2150 560 1750 mm 0 2 1 0 HP 0 2 0 75 kW 220 480 V 60 Hz 290 lbs 130 kg ADS 400 4...

Страница 5: ...Frequency Drive is incorporated for motor speed control This allows precise air flow adjustment so that the Metra Separator is accurately tuned for operation with any material The separation chamber...

Страница 6: ...venth output trays are collecting feed forage seeds The dust chaff and other light impurities are blown out with the airflow outside the Metra Separator or directed through the CDC Cyclone Dust Collec...

Страница 7: ...e wire and cable with hot wet oily surfaces or objects When working with treated seed it is necessary to conduct medical examinations and provide staff with personal protective equipment While operati...

Страница 8: ...ocess if necessary the conveyors will be completed as option 8 3 Connection to power supply The Metra Separator connection to power mains must be performed by a qualified electrician having electrical...

Страница 9: ...the grain or other clean material is not coming out with the light impurities removal 5 If the Metra Separator is equipped with CDC Cyclone Dust Collector make sure that all connections are tight wit...

Страница 10: ...ion chamber Please note The capacity of the Metra Separator can be increased the amount of grain fed into the separation chamber can be increased until the process of cleaning grading gets worse The e...

Страница 11: ...5 0 25 Peas 800 1 00 Hummel rice 700 0 50 Wheat 760 1 00 Awned rice 700 0 40 Corn 700 1 00 Sugar beet 300 0 40 Bread corn 700 0 9 Millet 850 0 30 Barley 650 0 8 Rapeseed 0 30 Vetch oatmeal mix 0 75 Li...

Страница 12: ...ng parts When withdrawing the Metra Separator from storage or preservation it is necessary to remove dust and dirt deposits using a soft cloth check the smoothness of the impeller rotation and carry o...

Страница 13: ...The Metra ADS Separator can be transported by any means of transport according to the shipping rules Placing and securing of cargo is carried out in accordance with the current technical rules of carg...

Страница 14: ...of the Metra Separator is carried out in a dry ventilated space Rainfall and foreign objects hit is not allowed STORAGE Date Storage conditions Storage type Remarks Accepted for storage Withdrawn fro...

Страница 15: ...15 REPAIR Date Operating time since the beginning of operation period hours Operating time after the last repair hours Reason for repair Information about repair...

Страница 16: ...16 MOVEMENT IN OPERATION Mounting date Mounting place Dismounting date Operating time from the beginning of operation period hours Reason for dismounting Full name and signature...

Страница 17: ...17 Metra Separator strapping scheme Annex 1...

Страница 18: ...18...

Отзывы: