19.3.2015
Metos Eco Kitchen
4
|
4. Installation
IND induction cooker series are of plug & play type, which is ready for use after power and water supplies
(if necessary) are connected.
4.1. Heat Radiation Requirements
• Adequate space (min. 50 mm) shall be left in the back and bottom of the unit to allow free flow of air.
Improper installation will result in blockage or decrease of airflow and poor radiation of heat;
• The air inlet and outlets
must not be obstructed.
• The inlet cold air should not be mixed with the outlet hot air;
• The inlet air temperature should not exceed 40ºC;
• The induction cooker (steamer) should be away from other heat sources (such as gas cooker or halo-
gen stove). In case several induction cookers are used, they should be at least 100mm apart from
each other. Besides, it should be ensured that there is sufficient supply of cold air and the hot air
discharged by cookers will not enter other cookers.
4.2. Fire Prevention
• All objects in contact with the cooker (steamer) should be made of noninflammable materials.
4.3. Requirements on Electrical Connection
• Check and make sure that the power supply is consistent with the rating on the nameplate of the
product;
• The electrical connection must comply with existing national and local regulations;
• The electrical cable of the product must be connected to the power supply with an appropriate plug;
• In case leakage protection is adopted, the maximum circuit-breaking current is 30mA.
5. Troubleshooting
Warning: There is high voltage inside! Do not open the cooker!
The cooker can only be opened by authorized servicing personnel.
In case the glass-ceramic panel breaks or cracks, immediately switch off the cooker and disconnect the
power. Never touch any exposed part inside the cooker.
When malfunction occurs, the indicator will show some information as follows:
Code
Possible Cause
Correcting Measure
E1 (01)
No Detecting the pan in the
heating zone.
• Place proper wok/ pan on the cooker;
• Consult professional personnel
E2 (02)
Over-current in Coils
• Change the utensil with more ferrous material
• Consult professional personnel
E3 (03)
Over-temperature of power
module, the equipment not
working
• Long working hours in high ambient temperature,
Cooling needed.
• If ambient temperature is not high, check if the
air-inlet and air-outlet is blocked, of if the warm air
from outlet can be sucked into the inlet.
• Check if the cooling fan of the generator works
properly.
• Check if the grease filter is too dirty.
STOP
STOP
STOP
Содержание IND-10P-3500
Страница 27: ...13 19 3 2015 Metos Eco Kitchen Liesi Spiis Range 3 5 kW Liesi Spiis Range 5 kW...
Страница 28: ...19 3 2015 Metos Eco Kitchen 14 Wok 3 5 kW Wok 5 kW...
Страница 29: ...15 19 3 2015 Metos Eco Kitchen Liesi Spiis Range 2x3 5 kW 2x5 kW...
Страница 30: ...19 3 2015 Metos Eco Kitchen 16...
Страница 31: ...17 19 3 2015 Metos Eco Kitchen...
Страница 32: ......