8.5.2015
Metos EMS
4
|
5. INSTALLATIONS
5.1. Location
This unit is intended for indoor use only.
Be sure the location chosen for your unit must be able to provide good air circulation for most efficient
refrigeration.
Avoid locations near heat sources such as stoves, ovens, fryers, and also direct sunlight where tempe-
ratures can reach extreme values. Besides, do not select a location in an area where temperatures may
drop below 12ºC (55ºF) or increase more than 25ºC (75ºF) and 60% Rh.
Furthermore, the floor at the final location must be strong enough to support the total weight of the
cabinet plus the maximum product load. Also, it must be level and free of vibration. Reinforce the floor
if necessary.
It is very important, avoid direct contact of the air conditioning apparatus.
5.2. Unpacking
The unit is shipped from the factory on a wooden pallet and packaged in a wooden container. The woo-
den is attached to the wooden base with the use of large staples. These should be first removed to avoid
scratching the unit when lifting off the crate.
All packaging materials used are environmentally friendly and may be recycled or reused. Actively contri-
bute to the protection of the environment by insisting on packaging recovery and removal methods that
are environmentally friendly.
The manufacturer does not recommend laying the unit down on its front, side or back. However, you
must be certain to allow the unit to remain in an upright position afterwards for at least 24 hours before
plugging it in so that the compressor oil and refrigerant may settle.
5.3. Ventilation
To assure maximum operating efficiency, the equipment should be located where a continuous air supply
can circulate underneath and behind the cabinet.
Restricting the air supply will generate an excessive heat load on the condensing unit and adversely af-
fect its operating efficiency. Do not at any time obstruct the grill area in the front of the cabinet in any way.
Any restriction of the proper air flow, total or partial, will avoid the warranty on the unit.
Avoid direct contact of the air
conditioning apparatus
Air Conditioning
Minimum distance required (mm)