background image

12

 |

Rev. 5.0 (from 01.08.2011)

Metos ARDOX S

5.3.2.  Positioning the Ardox S Drop-In range

The appliance is delivered partly disassembled. Depending of the model of the appliance the package 
contains the following parts:

Ardox S2 Drop-in Solid Top Cooking Unit: 

•  Hob assembly 

3753288 

1 pc.

•  Frame  

3753263 

1 pc.

•  Connection link  

3753452 

2 pc.

•  Screws ISO 1481-ST4,8x16 C (or other suitable type)   20 pcs.

•  Grease box 

3753432 

1 pc.

 

•  Installation and Operation Manual  

1 pc.

Ardox S4 Drop-In Solid Top Cooking Unit:

• Hob 

assembly 

3753284 

pc.

•  Frame  

3753257 

1 pc.

•  Connection link  

3753452 

2 pc.

•  Screws ISO 1481-ST4,8x16 C (or other suitable type) 

24 pcs.

•  Grease box 

3753432 

1 pc.

 

•  Installation and Operation Manual  

1 pc.

The appliance is intended for drop-in installation in the customer stainless steel table top. .

Installation in tabletops made from wood or other fl ammable surface is not allowed. 

Max. recommended thickness of table top ( external stainless steel plywood underneath) 
30mm. Dimensions of drop-in hole in table top must be as follows:

•  Ardox S2 Drop-in Solid Top Cooking Unit 

453mmx753mm

•  Ardox S4 Drop-in Solid Top Cooking Unit 

753mmx753mm

Please refer to the installation drawings and other drawings in chapter “Technical specifi cation”  and 
follow the installation steps described below:
•  Cut drop-in hole in table top according to model of appliance to be installed. .

•  Drop the frame into drop-in hole and fi x it to the tabletop by taping screws supplied with the appliance.

•  Drop carefully the onto the frame hob. Frame must be completely covered by the stainless steel 

frame of the hob. Orientation of the hob is correct when the drain hole is in front left corner.

The hob is heavy, handle it carefully. The S2 hob weighs about 40 kg and the S4 hob weighs about 70 kg.

5.4. Electrical 

installation

5.4.1. Ranges

Before making the connection to the mains, ensure that the voltage and frequency are as indicated on 
the appliance rating plate.

Should maintenance require the appliance to be tested before all the protective coverings are in place, 
please be particularly careful of the moving parts inside the casing as well as of live parts..

To facilitate future maintenance and to increase safety, install a separate disconnection switch for the 
range in the immediate vicinity of the appliance. The switch should disconnect the appliance completely  
from the mains supply.

All information needed to connect the range is to be found on the name plate, the connection diagram 
and the installation drawing.

STOP

STOP

Содержание ARDOX S 4 series

Страница 1: ...etop Drop In Accessories CHEF 200 CHEF 220 CHEF 240 height adjustment cupboard Valid from 01 08 2011 Rev 5 0 17 4 2019 Original instructions 4210016 4210023 4210143 4210048 4210168 4210104 4210111 421...

Страница 2: ...2 Rev 5 0 from 01 08 2011 Metos ARDOX S CAUTION Read the instructions before using the machine Manufacturer Metos AS Saha tee 18 Loo 74201 Harju maakond www metos ee...

Страница 3: ...ration instructions 8 4 1 Before use 8 4 2 Before using the height adjustable stand 8 4 3 Operation 8 4 3 1 Selecting cookware 8 4 3 2 Direct cooking 8 4 4 Using the range 8 4 5 Height adjustable stan...

Страница 4: ...rized by the manufacturer and using original spare parts Not complying with the above may put the safety of the appliance in danger 1 1 Symbols used in the manual This symbol informs about a situation...

Страница 5: ...owed When moving the appliance or servicing it it must be disconnected from the mains When washing be careful so that the electrical equipment of the appliance does not come in contact with water Do n...

Страница 6: ...ge while Chef series products have their own manuals The tabletop appliance is intended for installation on suitable kitchen at working surface The overall dimensions of the working surface should all...

Страница 7: ...p the controls power regulators and pilot lamps are delivered separately for installation in suitable location during installation Refer to chapter Installation for details Height adjustable stand The...

Страница 8: ...ng food directly on the hot surface of the solid at top and for keeping warm of food 4 4 Using the range Ranges intended for use aboard ships are equipped with a kettle support Using a range without t...

Страница 9: ...getting into the air inlets Cleaning of stainless steel surfaces When cleaning the stainless steel surfaces of the appliance use a slightly alkaline detergent pH 8 10 diluted in water according to ins...

Страница 10: ...er to the cookware Cooking is then fast and the operating life of the heating elements is extended 4 6 2 Service This appliance does not contain parts which can be serviced by the user Maintenance mus...

Страница 11: ...rgotten on without a pan may reach even 350 C it is mandatory to follow local re safety regulations when installing the range t When installing the range care should be given to ensure that there is a...

Страница 12: ...installation drawings and other drawings in chapter Technical speci cation and follow the installation steps described below Cut drop in hole in table top according to model of appliance to be instal...

Страница 13: ...electrical installation is as follows To perform the electrical connection of the appliance the deck of the hob must be opened Lift up the lid carefylly as it is heavy Lock the lid to the open positi...

Страница 14: ...as well as the functional description of the appliance before testing the range Test the range once it has been connected to the mains electricity Check that every cooking zone heats up and the corre...

Страница 15: ...is in the ON position the fuses overload protection have not blown in the fuse box Ask a quali ed person to check overload protection Should the range still not work contact an authorised agent Befor...

Страница 16: ...16 Rev 5 0 from 01 08 2011 Metos ARDOX S 7 Technical speci cations Installation drawings Technical speci cations...

Страница 17: ...6 0 1 2 3 4 5 6 0 1 2 3 4 5 6 0 1 2 3 4 5 6 0 1 2 3 4 5...

Страница 18: ...6 0 1 2 3 4 5 6 0 1 2 3 4 5 6 0 1 2 3 4 5 6 0 1 2 3 4 5 6 0 1 2 3 4 5 6 0 1 2 3 4 5...

Страница 19: ...6 0 1 2 3 4 5 6 0 1 2 3 4 5 6 0 1 2 3 4 5 6 0 1 2 3 4 5...

Страница 20: ...6 0 1 2 3 4 5 6 0 1 2 3 4 5 6 0 1 2 3 4 5 6 0 1 2 3 4 5 6 0 1 2 3 4 5 6 0 1 2 3 4 5...

Страница 21: ...6 0 1 2 3 4 5 6 0 1 2 3 4 5 6 0 1 2 3 4 5 6 0 1 2 3 4 5...

Страница 22: ...6 0 1 2 3 4 5 6 0 1 2 3 4 5 6 0 1 2 3 4 5 6 0 1 2 3 4 5 6 0 1 2 3 4 5 6 0 1 2 3 4 5...

Страница 23: ...6 0 1 2 3 4 5 6 0 1 2 3 4 5...

Страница 24: ...6 0 1 2 3 4 5 6 0 1 2 3 4 5 6 0 1 2 3 4 5 6 0 1 2 3 4 5...

Страница 25: ...6 0 1 2 3 4 5 6 0 1 2 3 4 5 6 0 1 2 3 4 5 6 0 1 2 3 4 5 6 0 1 2 3 4 5 6 0 1 2 3 4 5...

Страница 26: ......

Страница 27: ......

Страница 28: ......

Страница 29: ...kg Weight excluding package 4 Stand abt 93 kg Weight excluding package 4 Height adjusted abt 112 kg Weight excluding package 4 CHEF 200 220 abt 138 kg Weight excluding package 4 CHEF 240 abt 145 kg W...

Страница 30: ...0 x 920 x 1050 mm Package dimensions WxDxH 6 Height adj stand 1260 x 920 x 1050 mm Electricity connection See installation drawing Conditions of use Normal kitchen conditions above 0 C Standard equipm...

Страница 31: ...31 Rev 5 0 from 01 08 2011 Metos ARDOX S...

Страница 32: ......

Отзывы: