52
7.6.2011
METOS 700 Ranges, Gas solid top
8.1 APPLIANCE TYPE “A1”
• Position the “A1” type appliance below an extractor hood to
ensure smoke and fumes generated by cooking are remo-
ved.
8.2 APPLIANCE TYPE “B21”
• Position the “B21” type appliance below an extractor hood.
8.3 APPLIANCE TYPE “B11”
• Fit the “B11” type appliance with a suitable fl ue, available from
the appliance manufacturer. Follow the assembly instructions
provided with the fl ue.
• Connect the fl ue to a 150/155 mm diameter hose, heat resi-
stant to 300°C.
• Vent to the outside or into an effi cient fl ue. The hose length
must not exceed 3 metres.
9 CONNECTIONS
The position and dimensions of connections are given in the
installation diagram at the start of this manual.
9.1 CONNECTION TO THE GAS SUPPLY
Check that the appliance is designed to operate with the type
of gas supply present on site. Check the information given on
the decals on the packing and appliance. Convert the appliance
to the local gas type, if necessary. Follow the instructions at the
next paragraph “Conversion to a different type of gas”.
On top appliances a rear connection is also available. Remove
the plug present and screw it tightly onto the front connector.
• A rapid-action gas shut-off valve must be fi tted upstream of
the appliance in an easily accessible position.
• Do not use connection pipes having a diameter smaller than
that of the appliance’s gas connector.
• Once the appliance has been installed, check for gas leaks at
the connection points.
9.2 ELECTRICAL
CONNECTIONS
Check that the appliance is designed to operate at the voltage
and frequency of the power supply present on site. Check the
details given on the appliance dataplate.
• At an easily accessible point upline of the appliance, fi t an
all-pole disconnect switch of suitable capacity with a contact
breaking distance of at least 3 mm, and a highly sensitive dif-
ferential protection device. The maximum permitted leakage
current is 1 mA/kW.
• A fl exible rubber cable with insulation specifi cations not lower
than type H05 RN-F must be used for connection.
• Connect the power supply cable to the terminal board as
shown in the wiring diagram supplied with the appliance.
• Secure the power supply cable with the cable clamp.
• Protect the power supply cable on the outside of the applian-
ce with a rigid plastic or metal pipe.
9.3 PROTECTIVE EARTH AND EARTH BONDING CON-
NECTIONS
Connect the appliance to an effi cient ground circuit. Connect
the earth conductor to the terminal with the symbol
next to
the main terminal board.
Connect the metal structure of the appliance to the equipoten-
tial node. Connect the conductor to the terminal with the sym-
bol
on the outside part of the bottom.
• Identify the specifi c appliance model. The model number is
detailed on the packing and on the appliance dataplate.
• The appliance must be installed in a well-ventilated room.
• Do not obstruct any air vents or drains present on the ap-
pliance.
• Do not tamper with appliance components.
5 REFERENCE STANDARDS AND LAWS
Install the appliance in compliance with current standards.
Install the appliance in compliance with the prescriptions of
EN1717 and the water pollution regulations in force in your
country.
6 UNPACKING
Check the state of the packing and in the event of damage, ask
the delivery person to inspect the goods.
• Remove the packing
• Remove the protective fi lm from the outer panels. Use a sui-
table solvent to remove any residual adhesive from the pa-
nels.
7 POSITIONING
• The overall dimensions of the appliance and the position of
connections are given on the installation diagram at the start
of this manual.
• The appliance can be installed singly or in combination with
other appliances in the same product range.
• The appliance is not suitable for integrated installation.
• Position the appliance at least 10 cm from adjacent walls. This
distance can be reduced in the presence of non-combustible
walls or heat-insulated walls.
• Level the appliance by means of the height-adjustable feet
7.1 APPLIANCE ASSEMBLY WITH BASE, BRIDGE, AND
CANTILEVER SOLUTIONS
Follow the instructions provided with the type of support utili-
zed.
7.2 FIXING THE APPLIANCE TO THE FLOOR
Appliances of 40cms in width installed alone must be fi xed to
the fl oor. Use the fl anged feet provided.
7.3 JOINING APPLIANCES TOGETHER IN LINE
• Remove the control panels (A).
• Remove the fi xing screw nearest the panel from each of the
sides to be joined (B).
• Place the appliances side by side and adjust the tops to the
same height (C).
• Insert the connector plate ( supplied ) in the seat provided on
the side of the top. Join the appliances by screwing down the
connector plate (D) using the fl at-headed M5 screws (sup-
plied).
• Turn one of the two internal tabs of the appliances to be joi-
ned by 180° (E).
• Join the appliances by screwing the M5x40 screw on the op-
posite insert (F).
8 FUMES EXHAUST SYSTEM
Create a fumes exhaust system based on the “Type” of
appliance. The “Type” is stated on the appliance dataplate.