Note: It is the responsibility of the installer to ensure a water proof seal
is achieved between the faceplate and the finished surface of the wall.
If in any doubt about the quality of the seal, the faceplate should be re-
moved and then reinstalled using silicone to ensure a seal is achieved.
WMKA21005
IMPORTANT
Please read all of the instructions before installation
MA019328
Aroha 3 Hole Wall Mounted
Basin Set with Plate
01-9328
Use of this product is recommended for domestic and commercial applications.
All pipework must be thoroughly flushed prior to the installation of the mixer.
Inline filter washers must be installed on both hot and cold supplies to prevent foreign particles
damaging the ceramic head works.
Do not remove the ceramic head works from wall top assemblies when installing.
Methven recommends a licensed plumber carry out all installations in compliance with
the requirements of AS/NZS 3500. This product complies with AS/NZS 3718 regulations.
JUNE 2012
Installation Guide
Installation
1. Screw the breech set (1) into
the mounting stud. Refer to
illustration 1. for minimum and
maximum tolerances. Plumb
the breech set (1) into system.
2. A hole diameter of 35mm will
be required for correct head
works (2) installation and a
hole diameter of 25mm will be
required for correct spout (8)
installation.
3. Screw head works (2) into
breech (1).
4. Trim brass nipple (3) to length
with a max 15mm protruding
from wall lining.
5. Place the faceplate (6) over
the brass nipple (3) and
head works (2). Ensure that
faceplate (4) is flush with wall
surface It is recommended that
a clear bead of silicone sealant
is applied on the back of the
faceplate (4) before fixing to
finished wall surface.
6. Fit inlet connector (5) to brass
nipple (3) and place spout over
inlet connector (8).
7. Tighten with a 2.5mm hex key
(9).
8. Screw locking nut (6) and
handle base ring (10) over
spindle/head works (2).
9. Place handle (7) onto spindle
and fasten with a 2.5mm hex
key (9).
www.methven.com
Customer Care Hotline: 1300 METHVEN (638 483)
Email: [email protected]
2.5mm Allen key
Trim to
15mm
Ø 35mm
Ø 25mm
Ø 35mm
1.
2.
3.
5.
6.
Distance from mounting stud to
front of wall lining: Std - 56-60mm
Ext - 60-73mm
Apply appropriate thread
sealant material
Do not discard screws
For deeper installations,
remove short threaded
headworks collars and
replace with optional
04-9646 Spindle
Extension Kit.
4.
Hot
Col
d
(Available seperately)