The LED Display  

The high-contrast 4-1/2 digit LED display is easily read from across the room. It can register from 0000 to 
19999 counts. For ease of discussion, the 19999 will be rounded to 20000 in the remainder of this text. 
For example, we will refer to the 2V range, not the 1.9999V range. In all linear functions, the decimal point 
position is determined by the range selected. Polarity of the input signal is indicated by a ‘ – ‘ sign at the 
center of the left side of the LED. The + sign is disabled in the AC V, AC mA, and k

 measurement 

functions. The ‘ – ‘ sign may appear in any measurement function, but is normally not meaningful when 
making AC V, AC mA, and k

 measurements. You will only get this indication of an energized circuit if 

the power in the circuit is negative with respect to the COMMON input terminal. If the power in the circuit 
is positive with respect to the COMMON input terminal, an erroneous resistance will be displayed. If there 
is any doubt about whether there is energy remaining in the circuit you are reading, read the resistance, 
then reverse the test lead positions. If the minus sign is displayed in either case, the remaining energy 
must be removed from the circuit before correct resistance readings can be made. If you apply an input 
signal that exceeds the limits of the range selected, the LED display will flash. All decimal point positions 
appear in the display to indicate certain illegal combinations of front panel switch settings. For example, if 
you select the DCV function and the 20M range, all four decimal points will appear on the display.  

 
POWER Switch  

The green POWER switch is located in the right corner of the DMM front panel.  To turn the meter ON, 
push the POWER button in.  To turn the meter OFF, push the POWER button in. 
 

CAT I
1000V

DC 1200V
AC 1000V

500V
MAX

200uA  2mA     20mA  200mA   2A      20A

200mV     2         20      200

200     2k

G

      20k      200k     2M      20M

1000VAC
1200VDC

TRUE

RMS

20 A

20A MAX

AC

DC

mA-2A

2A MAX

POWER

BDM40

COM

V

1

3

2

6

5

4

W

  

WARNING

  

T

TO AVOID ELECTRICAL SHOCK
DISCONNECT TEST LEADS AND
POWER CORD BEFORE REMOVING
COVER.
DO NOT OPERATE INSTRUMENT
WITH COVER REMOVED.
TO PREVENT FIRE, REPLACE FUSE
WITH SAME AND RATING

MADE IN TAIWAN

SERIAL NO.

15 VA MAX

  50 Hz / 60 Hz 

B

117 VAC      105 VAC - 128 VAC

AC MAINS SELECTOR

117 V    230 V

117 VAC           F 0.125 A / 250V

MAINS SUPPLY     FUSE      

W

230 VAC           F 0.08 A / 250 V

230 VAC      210 VAC - 257 VAC

P

8

9

7

 

 

Figure 1:  BDM40 Controls 

 
1.   Voltage, Ohms and Diode inputs. 
2.   Current (mA to 2A) and 20A inputs. 
3.   Reading display 0000 to 19999. 
4.   Power button (green). 
5.   Range selection switches.  The pushbuttons 
are interlocked with the other ranges. 

6.   Function selection switches. 

 

The 

pushbuttons are interlocked with the other two 
white function  

selection switches  A  and  

7.   Line Power connector. 
8.   Line Voltage selector switch. 
9. Line 

Power 

Fuse. 

Содержание Meterman BDM40

Страница 1: ...Be nch Digit a l Mult im e t e r Operator s Manual Model BDM40 Bench Digital Multimeter...

Страница 2: ...nputs are protected against continuous overload conditions up to the limits of each function s stated input protection see specifications Never exceed these limits or the ratings marked on the instrum...

Страница 3: ...suitably rated and approved HBC mains fuse refer to the rating information on the equipment and or user instructions for details As a guide cable of 0 75 mm should be protected by a 3A or 5A fuse Lar...

Страница 4: ...y 1 year UNPACKING YOUR INSTRUMENT The shipping box should contain this manual your multimeter test leads one red and one black two spare fuses 2A two spare fuses 0 08A 230 V and 0 125A 117 V and 2 po...

Страница 5: ...s of the range selected the LED display will flash All decimal point positions appear in the display to indicate certain illegal combinations of front panel switch settings For example if you select t...

Страница 6: ...ude pulses Each measurement function is equipped with input overload protection Table 1 lists the overload limits for each function Input Connections to Common WARNING TO AVOID ELECTRICAL SHOCK AND OR...

Страница 7: ...ue the rms value was pi 2 2 1 2 2 pi 1 11 of the average value when measuring a sine wave Most meters used an average responding converter and multiplied by 1 11 to present true rms measurements of si...

Страница 8: ...n half power levels Your instrument has a bandwidth of greater than 200kHz Slew rate Slew rate is also called the rate limit or the voltage velocity limit It defines the maximum rate of change of the...

Страница 9: ...ses would have a zero rise time as shown in Figure 3 0 707 0 5 300 150 3 100 2 0 3 50 rms Total V 0 5 100 50 100 0 50 DC V 0 5 0 25 0 25 0 50 2 0 5 2 0 707 rms V AC When the maximum distortion in rise...

Страница 10: ...FUL NOT TO TOUCH THE PROBE TIPS WITH YOUR FINGERS OR TO ALLOW THE PROBE TIPS TO TOUCH EACH OTHER 7 Insert the probe tips of the test leads into the slots of a power outlet The LED should display the t...

Страница 11: ...RECTIFIED PK 0 PK PK RECTANGULAR PULSE PK 0 X Y D X Y K D D 2 PK PK TRIANGLE SAWTOOTH PK 0 RMS CAL IS DISPLAYED VALUE FOR AVERAGE RESPONDING METERS THAT ARE CALIBRATED TO DISPLAY RMS FOR DINE WAVES Yo...

Страница 12: ...C Total RMS Figure 5 RMS Values Insignificance of inherent meter offset If you short the input of your meter while the AC voltage function is selected you should have a reading of less than 10 digits...

Страница 13: ...t you may have to consider an error caused by the voltage drop across the meter in this case across the protective fuses and current shunts This voltage drop is called burden voltage The maximum full...

Страница 14: ...wing procedure to familiarize yourself with the resistance function and to see how the range switches affect decimal point position on the LED 1 With the test leads held apart select the 2000 k range...

Страница 15: ...d Service Information This DMM is warranted for a period of 1 year upon delivery to the original purchaser Conditions of the warranty are given on the first page of this manual and Service instruction...

Страница 16: ...ive guides Display Access Use the following procedure to remove or replace the LED 1 Carefully lay the display PCB to one side 2 Both the Main and Display PCBs should now be flat on your workbench com...

Страница 17: ...T display value lies within the indicated limits Table 5 Linear Voltage Test STEP UUT SWITCH POSITIONS UUT INPUT DISPLAY READING FUNCTION RANGE LEVEL FREQUENCY 1 2 200mV 190mVDC 190mVDC 189 90 to 190...

Страница 18: ...nput to the UUT and verify that the UUT display is within the indicated limits Table 7 Resistance Test STEP SELECT RANGE INPUT DISPLAY READING 1 2 3 4 5 6 7 200 200 2k 20k 200k 2000k 20M Short 100 1 k...

Страница 19: ...to 10 002 DC Current Calibration On the UUT select DC 20 A range and connect the 20A terminal to the calibrator HI amps output and COM to the calibrator LO amps output For each step in Table 10 selec...

Страница 20: ...d with clean dry low pressure air 20 psi or less Contaminants can be removed from the pcb using demineralized water and a soft brush remove the display assembly before washing the Main PCB and avoid g...

Страница 21: ...8 C to 50 C 32 F to 64 4 F and 82 4 F to 122 F Operating Temperature 0 C to 50 C 32 F to 122 F Storage Temperature 10 C to 70 C 14 F to 158 F Relative Humidity Up to 90 0 C to 35 C 32 95 F up to 70 35...

Страница 22: ...range and full range INPUT RESOL VOLTAGE UTION Range 20Hz 45Hz 1kHz 2kHz 10kHz 20kHz 50kHz 10mV 200mV 10 V 200mV 0 1V 2V 100 V 2V 1 0 5 1 2 5 1V 20V 1mV 20V 15 15 15 15 15 10V 200V 10mV 200V 100V 100...

Страница 23: ...es have enough voltage to turn on silicon junctions to check for proper forward to back resistance The 2k range is preferred and is marked with a large diode symbol on the front panel of the instrumen...

Страница 24: ...al in writing from Meterman Test Tools Specifications subject to change Meterman Test Tools 2003 U S Service Center Meterman Test Tools 1420 75th Street SW Everett WA 98203 Tel 888 993 5853 Fax 425 44...

Отзывы: