9
HYDROS 21
Operating Temperature Range
Minimum
0 °C
Maximum
50 °C
NOTE: Sensors may be used at higher temperatures under certain conditions; contact
for assistance.
Cable Length
10 m (standard)
20 m
40 m (maximum cable length)
Cable Diameter
6 mm
Connector Types
3.5-mm stereo plug connector or stripped and tinned wires
ELECTRICAL AND TIMING CHARACTERISTICS
Supply Voltage (VCC to GND)
Minimum
3.6 V
Typical
NA
Maximum
15.0 V
Digital Input Voltage (logic high)
Minimum
2.8 V
Typical
3.6 V
Maximum
5.0 V
Digital Input Voltage (logic low)
Minimum
–0.3 V
Typical
0.0 V
Maximum
0.8 V
Digital Output Voltage (logic low)
Minimum
NA
Typical
3.6 V
Maximum
NA