Operation
3-8
GUPS 2400A
–104 Operation Manual
3.9.3
RS-232 Protocol
The GUPS 2400A
–104 RS-232 communications port protocol is given in Table 3–4.
Baud Rate
9600
Data Bits
8
Start Bits
1
Stop Bits
1
Parity
None
Table 3
–4. RS-232 Communications Port Protocol
3.9.4
Test Data Request Commands
The GUPS 2400A
–104 RS-232 text data mode commands have been developed for a user
interface utilizing a dumb terminal interface. The text data mode commands provide formatted
responses that include both the name of data parameters and the measured values. Each of the
text data requests supported by the GUPS 2400A
–104 is described below.
3.9.4.1
List Selection Menu
Enter a ―space‖ (0x20) character to view the following menu:
k = Display calibration constants
l = ETI calibration
m = ETI A/D
n = ETI Float
s = Status registers
v = Display version