6 Operating instructions
6.1 Safety aspects
Never use this closed-circuit fireplace as an open fireplace.
So always keep all the glass panes or the door, including the window in the door, closed when the appliance is in
operation.
Do not use the appliance if the glass in the door is cracked or broken.
If defective, the glass must be replaced immediately by a competent Metalfire installer.
These gas fireplaces radiate significant levels of heat. The entire outside of the fireplace becomes extremely hot
(the metalwork, glass in the door, surface and surround).
So ensure that young children,
the elderly and disabled people stay a safe distance from the fireplace so that they
cannot come into contact with it and make sure there is a guard around the fire, if necessary.
Never let children operate the fireplace without supervision.
Make sure that flammable materials (wooden mantels, curtains, flammable liquids, furniture and so on) are always
separated from the fireplace by at least 1 metre both above and around it.
Following installation, all visible parts of the fireplace should be considered as active heating surfaces and
therefore should not be touched when the fireplace is in use. Touching these parts constitutes a risk of burns.
No other objects may be placed in the combustion chamber except the originally supplied ceramic log sets.
Using non-original decorative material invalidates the guarantee.
If the flame goes out for whatever reason, wait at least 3 minutes before reigniting the fireplace.
6.2 Remote control functions
6.2.1 Introduction
The RF remote control can be used to switch the fireplace on or off.
The fireplace operates using a pilot flame that burns continuously when the appliance is switched on.
This pilot flame ignites the main burner.
Using the RF remote control, it is possible to manually adjust the flame height or to manually set the required
temperature. It is also possible to activate the Ecowave function.
It is important that the remote control can always communicate with the receiver that is built into the fireplace. If
this communication fails, the fireplace will switch off. The standard reach is 6 metres.
To work properly, the remote control should be at room temperature.
Содержание AVENUE MF 1050-40 GHE
Страница 2: ...AVENUE_GHE_EN_07 2...
Страница 24: ...AVENUE_GHE_EN_07 24 The wall finish on the sides and front is aligned with the glass support frames...
Страница 48: ...AVENUE_GHE_EN_07 48 5 6 1 2 General connection diagram...
Страница 64: ...AVENUE_GHE_EN_07 64 If oxypilot is unscrewed unscrew the 4 screws M5 of the burner Burner Brander...
Страница 70: ...AVENUE_GHE_EN_07 70 5 15 1 Smoke style logs 5 15 1 1 Avenue MF 600 75 GHE et Avenue MF 700 60 GHE...
Страница 71: ...AVENUE_GHE_EN_07 71...
Страница 72: ...AVENUE_GHE_EN_07 72...
Страница 73: ...AVENUE_GHE_EN_07 73...
Страница 75: ...AVENUE_GHE_EN_07 75...
Страница 76: ...AVENUE_GHE_EN_07 76...
Страница 77: ...AVENUE_GHE_EN_07 77...
Страница 78: ...AVENUE_GHE_EN_07 78 5 15 1 3 Avenue MF 1050 40 GHE...
Страница 79: ...AVENUE_GHE_EN_07 79...
Страница 80: ...AVENUE_GHE_EN_07 80 5 15 1 4 Avenue MF 1300 40 GHE...
Страница 81: ...AVENUE_GHE_EN_07 81 5 15 1 5 Avenue MF 1600 40 GHE...
Страница 82: ...AVENUE_GHE_EN_07 82...
Страница 83: ...AVENUE_GHE_EN_07 83...
Страница 84: ...AVENUE_GHE_EN_07 84 5 15 2 Smoke style DELUXE logs Avenue MF 600 75 GHE et Avenue MF 700 60 GHE...
Страница 85: ...AVENUE_GHE_EN_07 85...
Страница 86: ...AVENUE_GHE_EN_07 86...
Страница 87: ...AVENUE_GHE_EN_07 87...