![Metal Samples MS2500L Скачать руководство пользователя страница 12](http://html1.mh-extra.com/html/metal-samples/ms2500l/ms2500l_operators-manual_1776975012.webp)
8
IV. Accessories
A. MS2510 Receiver/Power Supply
When operated together, the MS2510 receiver and MS2500L transmitter provide the corrosion
investigator with a low-cost, 4-20mA corrosion monitoring system. Data received from the transmitter is
displayed on the receiver’s front panel, a three digit L.E.D. The three-position function switch, located
at the center of the receiver’s front panel, permits the data to be displayed in one of two formats,
depending on switch position: milliamps and corrosion rate (MPY). Located at the back of the receiver
are 4-20mA and 10V output terminals for connection of the receiver to a customer-supplied computer,
data logger, or recorder; connection terminals for the MS2500L; and an AC power cord connector.
General Specifications - MS2510
Display:
3-digit L.E.D. display to give:
a) Loop Current (in mA)
b) Probe Reading (0-100 MPY)
Dimensions:
Length: 5.25"
Width: 2.0"
Height: 6.6"
Required
Installation Space:
4.3" x 2"
Weight:
3 lbs.
Electrical Specifications - MS2510
Power Requirements:
120/240V AC 50/60 Hz @ ½ Amp
Outputs:
24V DC - 4 to 20 mA current loop drive
4-20mA - isolated output to CPU, etc.
0-10V - isolated output to chart recorder