INSTRUCTIONS
1.
Locking Key, METABO motor
:
After switch on the motor, press the locking key, loose the switch, the motor will non-stop working; Press
again, the motor switch off.
2.
Direction selector
:
For change the rotation direction: clockwise or anticlockwise. Due to the tool feed required
clockwise, so the direction selector locked before dispatch to customers. Cannot change the rotation
direction.
3.
Speed changer
:
Mechanical speed change, speed ratio of 3.1. Can only change the speed statically. (Change speed
statically means when change the speed grade, switch off the machine) Grade 1: Low speed, high
torque output
Grade 2: High speed, low torque output
Usually adopts low grade high speed, means “1-E”, “1-F” or “1-G”
When working thin wall pipe, can adopt high grade low speed, means “2-A” or “2-B”
4.
Signal lamp:
METABO motor signal device, when using, should pay attention to.
If the yellow light flashing, show that the carbon brush wear almost completely, need to change the new one;
If the yellow light frequent flashing, indicates that the power poor contact;
If the yellow light always be on, show that motor overload, high temperature, motor will overload
protection, as shown in figure B.
5.
Speed governor
:
Electronic speed governor, from A to G, speed from slow to fast, can adjust speed dynamically. (Adjust
speed dynamically means can adjust the speed while machine working)
Figure B: Speed governor and Signal Light
Figure C: Speed Changer