HG 16-500
Output:
1600 W
Air temperature:
Stage 1: ..................... 300 °C
Stage 2: .................... 500 °C
Air volume:
stage 0: ............................ off
Stage 1: ..................240 l/min
Stage 2: ..................450 l/min
Thermal protection: only thermal fuse
Weight
600 g (20.8 oz)
Sound pressure level:< 70 dB (A)
Vibration:
< 2.5 m/s
2
HG 20-600
Output:
2000 W
Air temperature:
stage 1: ......................80 °C
Stage 2: ............. 80-600 °C
Stage 3: .............. 80-600 °C
Air volume:
stage 0: ...........................off
Stage 1: ................ 150 l/min
Stage 2: ................ 300 l/min
Stage 3: ................ 500 l/min
Temperature
Setting:
stepless in 9 stages
per wheel
Thermal protection: only thermal fuse
Weight
620 g (22.0 oz)
Sound pressure level:< 70 dB (A)
Vibration:
< 2.5 m/s
2
HGE 23-650 LCD
Output:
2100 W (max 2300 W)
Air temperature:
Stage 1: ......................80 °C
Stage 2: .............. 80-650 °C
Blower:
steplessly adjustable
Air volume:
stage 1: ...........150-250 l/min
Stage 2: ...........150-500 l/min
Programs:
1=250°C /
approx.350 l/
min
2=350°C /
approx.400 l/
min
3=450°C /
approx. 500 l/
min
4=550°C /
approx. 400 l/
min
Temperature display:LCD in 10 °C steps
Thermal protection: yes
Weight
700 g (24.2 oz)
Sound pressure level:< 70 dB (A)
Vibration:
< 2.5 m/s
2
HGS 22-630
Output:
2100 W (max 2200 W)
Air temperature:
stage 1: ...............80-630 °C
Stage 2: ...............80-630 °C
Air volume:
stage 0: ...........................off
Stage 1: ......... 150-300 l/min
Stage 2: ......... 300-500 l/min
Temperature
Setting:
stepless in 9 stages
per wheel
Thermal protection: only thermal fuse
Weight
650 g (23.0 oz)
Sound pressure level:< 70 dB (A)
Vibration:
< 2.5 m/s
2
Changes due to technological progress reserved.
Values measured as per EN 60745.
Machine in protection class II
The technical specifications quoted are subject to
tolerances (in compliance with relevant valid
standards).
11. Environmental Protection
12. Technical Specifications