24
English
Problem
Possible Cause
Remedy
The thermal overload
protector cuts out
repeatedly.
A poorly ventilated room is causing the
motor to overheat.
Move the compressor to well-ventilated
area.
The air receiver
pressure drops when the
compressor shuts o
ff
.
The connections are loose or leaking
(
fi
ttings, tubing, etc.).
The drain valve is loose.
The check valve is leaking.
Check all the connections with soapy water
and look for bubbles. Tighten any loose
conections until the leak stops.
Tighten the drain valve.
Take the compressor to a service center.
WARNING
Do not disassemble check valve
while air is in tank
-
empty the
all the air out of the tank before
dissasembly.
There is excessive
moisture in the air
discharge.
There is excessive water in the tank.
The humidity is high.
Drain the tank to remove water.
Move the compressor to an area of less
humidity or use an air line
fi
lter to reduce
moisture discharge in the tank.
Air is leaking from the
compressor.
The hose connection is loose or improperly
sealed.
The air hose is broken or damaged.
Ensure connections are sealed with thread
sealing tape and tightened.
Replace the air hose.
The compressor runs
continuously
The drain valve is open.
The power switch is defective.
The usage is excessive.
Ensure the drain valve is closed.
Take the compressor to a service center.
Decrease the amount of tool run-time; the
compressor is not large enough to supply
the air requirement of the tool.
The compressor vibrates. The compressor mounting bolts are loose. Tighten mounting bolts.
The air output is lower
than normal.
The inlet valves are broken.
The connections are leaking.
Take the compressor to a service center.
Apply thread sealing tape to
fi
tting and
tighten.
Battery cannot be
installed
Attempting to install a battery other than
that speci
fi
ed for the tool.
Please install a multi volt type battery.
2. Charger
Symptom
Possible cause
Remedy
The charge indicator lamp
rapidly
fl
ickers purple, and
battery charging doesn’t
begin.
The battery is not inserted all the way.
Insert the battery
fi
rmly.
There is foreign matter in the battery
terminal or where the battery is attached.
Remove the foreign matter.
The charge indicator lamp
blinks red, and battery
charging doesn’t begin.
The battery is not inserted all the way.
Insert the battery
fi
rmly.
The battery is overheated.
If left alone, the battery will automatically
begin charging if its temperature
decreases, but this may reduce battery
life. It is recommended that the battery be
cooled in a well-ventilated location away
from direct sunlight before charging it.
00Book̲EC36DA̲NA.indb 24
00Book̲EC36DA̲NA.indb 24
2021/07/08 9:36:18
2021/07/08 9:36:18